Bernardo Lopes Poncetti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bernardo Lopes Poncetti has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Marcos Massao Futai
Universidade de São Paulo
8 shared publications - Dianelys Vega Ruiz
Polytechnic School of the Universidade de São Paulo
5 shared publications - Lucas Bellini Machado
Polytechnic School of the Universidade de São Paulo
5 shared publications - Leandro Silva de Assis
Department of Structural and Geotechnical Engineering, Polytechnic School, University of São Paulo, São Paulo, Brazil
4 shared publications - Romel Dias Vanderlei
Universidade Estadual de Maringá, Brasil
2 shared publications - Túlio Nogueira Bittencourt
Department of Structural and Geotechnical Engineering, University of São Paulo, São Paulo, Brazil
2 shared publications
Latest Publications
- 1 October 2025
- Published by Springer Nature
- p. 852-861
Population-Based Damage Detection Using Bidirectional LSTM and GRU Networks
- 1 October 2025
- Published by Springer Nature
- p. 852-861
Population-Based Damage Detection Using Bidirectional LSTM and GRU Networks
- 22 September 2025
- Published by Elsevier in Tunnelling and Underground Space Technology
- Vol. 168
Drone-based photogrammetry and virtual reality: technological alternatives for tunnel inspection
- 22 September 2025
- Published by Elsevier in Tunnelling and Underground Space Technology
- Vol. 168
Drone-based photogrammetry and virtual reality: technological alternatives for tunnel inspection
- 21 July 2025
- Published by Elsevier in Tunnelling and Underground Space Technology
- Vol. 165
Automated procedural modeling for tunnel inspection and digital twin development
- 21 July 2025
- Published by Elsevier in Tunnelling and Underground Space Technology
- Vol. 165
Automated procedural modeling for tunnel inspection and digital twin development
- Open Access
- 4 June 2025
- Published by MDPI AG in Applied Mechanics
- Vol. 6 (2) , 41
Tunnel Inspection Review: Normative Practices and Non-Destructive Method Advancements for Tunnels with Concrete Cover
Guaranteeing tunnel integrity is an important issue for several countries worldwide. Due to the continuous increase in the number of tunnels, as well as the aging of old tunnels, several countries and companies have created manuals to standardize tunnel inspection and assessment. Most manuals still specify just visual procedures for tunnel inspection; however, because of underground conditions, the structural system of tunnels is often accessible only by one side, thus posing difficulties to the accurate evaluation of the structural conditions of the tunnel using only visual inspection. A possibility to improve the effectiveness of tunnel inspection is the use of non-destructive testing (NDT), which will assist in obtaining information about the inner condition behind the tunnel wall. The current advancements in the NDT methods allow them to be employed in all the different kinds of inspections (initial, routine, special inspection) suggested by the manuals. Therefore, in an attempt to help in the decision about the application of each method, this work provides an overview of some international practices for tunnel inspections and shows a review of different NDT methods (traditional and new methods) applied to tunnel inspections. Furthermore, this study describes their workability, advantages, and capability, and classifies the best fitting of each in the inspection procedures.
- 4 June 2025
- Published by MDPI AG in Applied Mechanics
- Vol. 6 (2) , 41
Open AccessTunnel Inspection Review: Normative Practices and Non-Destructive Method Advancements for Tunnels with Concrete Cover
Guaranteeing tunnel integrity is an important issue for several countries worldwide. Due to the continuous increase in the number of tunnels, as well as the aging of old tunnels, several countries and companies have created manuals to standardize tunnel inspection and assessment. Most manuals still specify just visual procedures for tunnel inspection; however, because of underground conditions, the structural system of tunnels is often accessible only by one side, thus posing difficulties to the accurate evaluation of the structural conditions of the tunnel using only visual inspection. A possibility to improve the effectiveness of tunnel inspection is the use of non-destructive testing (NDT), which will assist in obtaining information about the inner condition behind the tunnel wall. The current advancements in the NDT methods allow them to be employed in all the different kinds of inspections (initial, routine, special inspection) suggested by the manuals. Therefore, in an attempt to help in the decision about the application of each method, this work provides an overview of some international practices for tunnel inspections and shows a review of different NDT methods (traditional and new methods) applied to tunnel inspections. Furthermore, this study describes their workability, advantages, and capability, and classifies the best fitting of each in the inspection procedures.
- Open Access
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Revista IBRACON de Estruturas e Materiais
- Vol. 18 (2) , e18207
An overview of Brazilian concrete tunnel inspection practices and international procedures
The evaluation of the structural integrity of tunnels in Brazil poses significant challenges due to the absence of established guidelines, manuals, or regulatory documents regarding the inspection and maintenance protocols. This article thus endeavors to relate the best international practices with those currently employed in Brazil to contribute to possible improvements. A comprehensive comparative analysis of inspection methodologies is presented, encompassing the classification of pathologies, prescribed inspection intervals, training protocols for inspectors, and methodologies for assessing assets' criticality. The study aims to inform the development of recommendations tailored to the Brazilian context for effectively inspecting concrete tunnels. By combining global and local practices, this research seeks to enhance the efficiency and safety of tunnel infrastructure in Brazil.
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Revista IBRACON de Estruturas e Materiais
- Vol. 18 (2) , e18207
Open AccessAn overview of Brazilian concrete tunnel inspection practices and international procedures
The evaluation of the structural integrity of tunnels in Brazil poses significant challenges due to the absence of established guidelines, manuals, or regulatory documents regarding the inspection and maintenance protocols. This article thus endeavors to relate the best international practices with those currently employed in Brazil to contribute to possible improvements. A comprehensive comparative analysis of inspection methodologies is presented, encompassing the classification of pathologies, prescribed inspection intervals, training protocols for inspectors, and methodologies for assessing assets' criticality. The study aims to inform the development of recommendations tailored to the Brazilian context for effectively inspecting concrete tunnels. By combining global and local practices, this research seeks to enhance the efficiency and safety of tunnel infrastructure in Brazil.
- Open Access
- 2 December 2024
- Published by Softaliza Tecnologias LTDA in Ibero-Latin American Congress on Computational Methods in Engineering (CILAMCE)
Structural damage identification through machine learning approaches using FRFs
In this paper, experimental tests and numerical simulations are conducted to evaluate the performance of different models for structural damage identification and quantification. For this purpose, an aluminum beam in Laboratory conditions is utilized as a test structure. Firstly, impact tests are performed to identify the modal parameters and frequency response functions (FRFs) of the healthy structure. Then,different damages are induced in the beam by means of rectangular notches, and FRFs from each damage scenario are measured. Meanwhile, a simplified numerical model of finite elements of the beam is developed and calibrated with respect to experimental data. The calibrated model is used to generate a set of simulations representing the different damage scenarios induced experimentally. The damage is introduced in the numerical model by reducing the cross-sectional area. Normalized FRF amplitudes are used as the damage indexes. To increase the predictive capability of the models, uncertainties are introduced considering the FRF amplitudes as random variables. Afterward, different datasets are constructed and several well-established machine learning classifiers such as Decision Tree, SVM and KNN are trained to perform damage identification and quantification. Finally, experimental data measured on the damaged beam are used as input variables to evaluate the prediction capacity of the trained classifiers. Undamaged and damaged data are correctly classified by most of the classifiers. However, to quantify the degree of damage some shortcomings are found.
- 2 December 2024
- Published by Softaliza Tecnologias LTDA in Ibero-Latin American Congress on Computational Methods in Engineering (CILAMCE)
Open AccessStructural damage identification through machine learning approaches using FRFs
In this paper, experimental tests and numerical simulations are conducted to evaluate the performance of different models for structural damage identification and quantification. For this purpose, an aluminum beam in Laboratory conditions is utilized as a test structure. Firstly, impact tests are performed to identify the modal parameters and frequency response functions (FRFs) of the healthy structure. Then,different damages are induced in the beam by means of rectangular notches, and FRFs from each damage scenario are measured. Meanwhile, a simplified numerical model of finite elements of the beam is developed and calibrated with respect to experimental data. The calibrated model is used to generate a set of simulations representing the different damage scenarios induced experimentally. The damage is introduced in the numerical model by reducing the cross-sectional area. Normalized FRF amplitudes are used as the damage indexes. To increase the predictive capability of the models, uncertainties are introduced considering the FRF amplitudes as random variables. Afterward, different datasets are constructed and several well-established machine learning classifiers such as Decision Tree, SVM and KNN are trained to perform damage identification and quantification. Finally, experimental data measured on the damaged beam are used as input variables to evaluate the prediction capacity of the trained classifiers. Undamaged and damaged data are correctly classified by most of the classifiers. However, to quantify the degree of damage some shortcomings are found.
- 25 January 2024
- Published by Springer Nature
- p. 157-176
Digital Twins for Condition Assessment of Railway Infrastructures
- 25 January 2024
- Published by Springer Nature
- p. 157-176
Digital Twins for Condition Assessment of Railway Infrastructures
- 15 December 2023
- Published by Wiley in Structural Concrete
- Vol. 25 (3) , 1801-1818
Effect of ultra‐high performance concrete repair layer thickness on the behavior of concrete columns
The use of ultra‐high‐performance fiber reinforced concrete (UHPFRC) to repair or rehabilitate old concrete structures has been shown to be appropriate due to its properties, such as higher compressive strength, ductility, and durability than conventional concretes. One of the studied strengthening techniques is the reinforced concrete columns jacketing by UHPFRC. Some recent research evaluated some parameters, such as the repair thickness and the volumetric ratio of stirrups. However, other important parameters, such as UHPFRC jacketing thickness in different column cross‐sections and the concrete core compressive strength, need to be addressed. In addition, the analytical models presented in the literature are restricted to only one concrete grade. The present study aims to evaluate the behavior of short reinforced concrete columns strengthened with UHPFRC subjected to centered compression. Numerical analyses of three‐dimensional models were performed using the finite element method, validated, and calibrated using experimental results. The influence of the concrete core compressive strength, the UHPFRC jacketing thickness, and the shape of the cross‐section were evaluated. Numerical simulations concluded that the lower concrete core compressive strength columns showed the best relative increase performance. Moreover, the concrete core strength was inversely proportional to the resistance capacity of the repair system. In addition, the increase in repair thickness contributes to the axial strength of the column. Furthermore, the cross‐section influences the distribution of stresses and strains, showing the best performance for circular sections. Finally, regardless of cross‐section type, the proposed equations accurately predicted the numerical results.
- 15 December 2023
- Published by Wiley in Structural Concrete
- Vol. 25 (3) , 1801-1818
Effect of ultra‐high performance concrete repair layer thickness on the behavior of concrete columns
The use of ultra‐high‐performance fiber reinforced concrete (UHPFRC) to repair or rehabilitate old concrete structures has been shown to be appropriate due to its properties, such as higher compressive strength, ductility, and durability than conventional concretes. One of the studied strengthening techniques is the reinforced concrete columns jacketing by UHPFRC. Some recent research evaluated some parameters, such as the repair thickness and the volumetric ratio of stirrups. However, other important parameters, such as UHPFRC jacketing thickness in different column cross‐sections and the concrete core compressive strength, need to be addressed. In addition, the analytical models presented in the literature are restricted to only one concrete grade. The present study aims to evaluate the behavior of short reinforced concrete columns strengthened with UHPFRC subjected to centered compression. Numerical analyses of three‐dimensional models were performed using the finite element method, validated, and calibrated using experimental results. The influence of the concrete core compressive strength, the UHPFRC jacketing thickness, and the shape of the cross‐section were evaluated. Numerical simulations concluded that the lower concrete core compressive strength columns showed the best relative increase performance. Moreover, the concrete core strength was inversely proportional to the resistance capacity of the repair system. In addition, the increase in repair thickness contributes to the axial strength of the column. Furthermore, the cross‐section influences the distribution of stresses and strains, showing the best performance for circular sections. Finally, regardless of cross‐section type, the proposed equations accurately predicted the numerical results.
- Open Access
Influence of Wetting Conditions and Concrete Strength of Both Substrate and Repair Material on the Bond Capacity of Repaired Joints
Ultra-high performance concrete (UHPC) is an appropriate material to repair and rehabilitate aged structures due to its excellent properties, such as high compressive strength and durability. Several studies have demonstrated the effectiveness of applying UHPC in old buildings as a rehabilitation or repair material, but the bond between concretes needs more investigation. In this sense, the bond between normal-strength concrete (NSC) and UHPC is currently being studied. Three main parameters are responsible for ensuring a good bond: the surface treatment of the substrate (roughness), the wetting conditions, and the mechanical strength of the substrate. Thus, the present study investigated the bond between concretes experimentally. The concrete of the substrate was carried out in three grades: C25, C45, and C60. The repair concretes were C25, C45, C60, and UHPC. The following parameters were evaluated: wetting conditions, air surface dry (ASD), saturated surface dry (SSD), substrate strength, and repair concrete strength. All models received surface treatment by wire brushing. Slant shear and splitting tensile tests were performed to evaluate the mechanical behavior and the failure modes of the bond between concretes. The bond strength was classified and compared to existing predicting models. The results showed that most expressive strength gains occurred in SSD models with lower strength substrates and UHPC. Furthermore, the influence of surface wetting conditions becomes smaller as the strength of the substrate is reduced.
Open AccessInfluence of Wetting Conditions and Concrete Strength of Both Substrate and Repair Material on the Bond Capacity of Repaired Joints
Ultra-high performance concrete (UHPC) is an appropriate material to repair and rehabilitate aged structures due to its excellent properties, such as high compressive strength and durability. Several studies have demonstrated the effectiveness of applying UHPC in old buildings as a rehabilitation or repair material, but the bond between concretes needs more investigation. In this sense, the bond between normal-strength concrete (NSC) and UHPC is currently being studied. Three main parameters are responsible for ensuring a good bond: the surface treatment of the substrate (roughness), the wetting conditions, and the mechanical strength of the substrate. Thus, the present study investigated the bond between concretes experimentally. The concrete of the substrate was carried out in three grades: C25, C45, and C60. The repair concretes were C25, C45, C60, and UHPC. The following parameters were evaluated: wetting conditions, air surface dry (ASD), saturated surface dry (SSD), substrate strength, and repair concrete strength. All models received surface treatment by wire brushing. Slant shear and splitting tensile tests were performed to evaluate the mechanical behavior and the failure modes of the bond between concretes. The bond strength was classified and compared to existing predicting models. The results showed that most expressive strength gains occurred in SSD models with lower strength substrates and UHPC. Furthermore, the influence of surface wetting conditions becomes smaller as the strength of the substrate is reduced.