Zhiyu Ma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zhiyu Ma has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Ke Deng
National Gravitation Laboratory, MOE Key Laboratory of Fundamental Physical Quantities Measurement, School of Physics Huazhong University of Science and Technology Wuhan China
5 shared publications - Wenhao Yuan
National Gravitation Laboratory, MOE Key Laboratory of Fundamental Physical Quantities Measurement, and School of Physics, Huazhong University of Science and Technology , Wuhan 430074
4 shared publications - Jie Zhang
Huazhong University of Science and Technology
3 shared publications - Zehuang Lu
National Gravitation Laboratory, MOE Key Laboratory of Fundamental Physical Quantities Measurement, and School of Physics, Huazhong University of Science and Technology, Wuhan 430074, People’s Republic of China
3 shared publications B. Wang
MOE Key Laboratory of Fundamental Physical Quantities Measurement, Hubei Key Laboratory of Gravitation and Quantum Physics, PGMF and School of Physics, Huazhong University of Science and Technology, Wuhan 430074, People’s Republic of China
2 shared publicationsF. F. Wu
MOE Key Laboratory of Fundamental Physical Quantities Measurement, Hubei Key Laboratory of Gravitation and Quantum Physics, PGMF and School of Physics, Huazhong University of Science and Technology, Wuhan 430074, People’s Republic of China
2 shared publications
Latest Publications
- 14 July 2025
- Published by IOP Publishing in Metrologia
- Vol. 62 (4) , 045002
Absolute frequency measurement of an Al + ion optical clock through a GNSS link to the SI second
We report an absolute frequency measurement of the 27 Al + ion 1 S 0 ↔ 3 P 0 optical clock transition, through a GNSS link to International Atomic Time (TAI) to ensure the traceability to the International System of Units (SI) second. The data were taken over a 22 d period, with the absolute frequency measured to be 1 121 015 393 207 856(16) Hz, with a relative standard uncertainty of 1.4 × 10 − 14 . The result confirms the reliability of the 27 Al + ion as a secondary representation of the SI second and contributes to the process of redefining the SI second based on optical transitions.
- 14 July 2025
- Published by IOP Publishing in Metrologia
- Vol. 62 (4) , 045002
Absolute frequency measurement of an Al + ion optical clock through a GNSS link to the SI second
We report an absolute frequency measurement of the 27 Al + ion 1 S 0 ↔ 3 P 0 optical clock transition, through a GNSS link to International Atomic Time (TAI) to ensure the traceability to the International System of Units (SI) second. The data were taken over a 22 d period, with the absolute frequency measured to be 1 121 015 393 207 856(16) Hz, with a relative standard uncertainty of 1.4 × 10 − 14 . The result confirms the reliability of the 27 Al + ion as a secondary representation of the SI second and contributes to the process of redefining the SI second based on optical transitions.
- 1 December 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (12)
A compact and fast radio-frequency source for efficient Raman sideband cooling
A compact and fast radio-frequency (RF) source developed for Raman sideband cooling (RSBC) in trapped ion and cold atom experiments is presented. The source is based on direct digital synthesizer, advanced real-time infrastructure for quantum physics, and field programmable gate array. The source has a frequency switching speed of 40 ns and can output continuous μs-level time sequences for RSBC. The maximum output frequency of the source is 1.4 GHz. The RF source is capable of pre-writing data for eight channels. As a demonstration, the RF source is applied to our 25Mg+–27Al+ ion pair optical clock experiment. In order to cool down the ion pair to the vibrational ground state, two-order RSBC is applied to the 25Mg+ ion. As a result, the ion pair motions in the three X, Y, and Z directions are all cooled to the vibrational ground state efficiently, demonstrating the feasibility of this technique. The developed RF source can be widely implemented for other cold atom experiments.
- 1 December 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (12)
A compact and fast radio-frequency source for efficient Raman sideband cooling
A compact and fast radio-frequency (RF) source developed for Raman sideband cooling (RSBC) in trapped ion and cold atom experiments is presented. The source is based on direct digital synthesizer, advanced real-time infrastructure for quantum physics, and field programmable gate array. The source has a frequency switching speed of 40 ns and can output continuous μs-level time sequences for RSBC. The maximum output frequency of the source is 1.4 GHz. The RF source is capable of pre-writing data for eight channels. As a demonstration, the RF source is applied to our 25Mg+–27Al+ ion pair optical clock experiment. In order to cool down the ion pair to the vibrational ground state, two-order RSBC is applied to the 25Mg+ ion. As a result, the ion pair motions in the three X, Y, and Z directions are all cooled to the vibrational ground state efficiently, demonstrating the feasibility of this technique. The developed RF source can be widely implemented for other cold atom experiments.
- 1 May 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (5)
Noise characterization of an ultra-stable laser for optical clocks
We report on the development and performance evaluation of an ultra-stable laser for an 27Al+ optical clock. After a series of noise suppressions, especially the vibrational and temperature fluctuation noise, the 30 cm long cavity stabilized laser obtains a frequency instability of 1.3 × 10−16 @1 s. This result is predicted by noise summation and confirmed by the three-cornered hat method. The 27Al+ optical clock transition is also used to characterize the laser frequency noise, and consistent results are yielded. This is the first reported instance of using single ion optical clocks to measure the frequency noise of ultra-stable lasers, as far as we know. With the implementation of the ultra-stable clock laser, an ultra-narrow linewidth clock transition of 2.8 Hz is obtained.
- 1 May 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (5)
Noise characterization of an ultra-stable laser for optical clocks
We report on the development and performance evaluation of an ultra-stable laser for an 27Al+ optical clock. After a series of noise suppressions, especially the vibrational and temperature fluctuation noise, the 30 cm long cavity stabilized laser obtains a frequency instability of 1.3 × 10−16 @1 s. This result is predicted by noise summation and confirmed by the three-cornered hat method. The 27Al+ optical clock transition is also used to characterize the laser frequency noise, and consistent results are yielded. This is the first reported instance of using single ion optical clocks to measure the frequency noise of ultra-stable lasers, as far as we know. With the implementation of the ultra-stable clock laser, an ultra-narrow linewidth clock transition of 2.8 Hz is obtained.
- 8 April 2024
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 21 (4) , 044017
Quantum-logic-based - optical frequency standard for the redefinition of the SI secondOptical clocks have been demonstrated to be good choices to redefine the SI “second.” With this goal, we have constructed a quantum-logic-based ion optical clock with a fractional frequency uncertainty of . A ion is used as the logic ion for sympathetic cooling, state readout, and frequency-shift measurement of the ion. The stability of the optical clock is , measured with a self-comparison method.- 8 April 2024
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 21 (4) , 044017
Quantum-logic-based - optical frequency standard for the redefinition of the SI secondOptical clocks have been demonstrated to be good choices to redefine the SI “second.” With this goal, we have constructed a quantum-logic-based ion optical clock with a fractional frequency uncertainty of . A ion is used as the logic ion for sympathetic cooling, state readout, and frequency-shift measurement of the ion. The stability of the optical clock is , measured with a self-comparison method.- 27 February 2023
- Published by American Physical Society (APS) in Physical Review A
- Vol. 107 (2) , L020803
Precision measurement of -ion and transition frequenciesPrecision measurement of ion and doublet transition frequencies plays a significant part in the study of space-time variation of fundamental physical constant . Here, we report a precision measurement of ion and doublet transition frequencies using the decoherence-assisted spectroscopy method with the full use of spontaneous emission signals to improve the detection sensitivity. We obtain the transition frequencies of with uncertainties of 0.12 and 0.24 MHz, respectively, which are one third of that in [A. Ozawa et al., Nat. Commun. 8, 44 (2017)]. Simultaneously, we obtain the experimental and theoretical values of the hyperfine structure constants in this work. The differences between the measured magnetic dipole constants MHz, MHz and the theoretical values MHz, MHz are within , while the measured electric quadrupole constant MHz and the theoretical value of MHz shows a difference of more than , indicating that considerations of more physical effects in theoretical calculation, such as the possible capture of electron correlations, is required.- 27 February 2023
- Published by American Physical Society (APS) in Physical Review A
- Vol. 107 (2) , L020803
Precision measurement of -ion and transition frequenciesPrecision measurement of ion and doublet transition frequencies plays a significant part in the study of space-time variation of fundamental physical constant . Here, we report a precision measurement of ion and doublet transition frequencies using the decoherence-assisted spectroscopy method with the full use of spontaneous emission signals to improve the detection sensitivity. We obtain the transition frequencies of with uncertainties of 0.12 and 0.24 MHz, respectively, which are one third of that in [A. Ozawa et al., Nat. Commun. 8, 44 (2017)]. Simultaneously, we obtain the experimental and theoretical values of the hyperfine structure constants in this work. The differences between the measured magnetic dipole constants MHz, MHz and the theoretical values MHz, MHz are within , while the measured electric quadrupole constant MHz and the theoretical value of MHz shows a difference of more than , indicating that considerations of more physical effects in theoretical calculation, such as the possible capture of electron correlations, is required.