Kawther Ben Mabrouk
Research Subjects
Kawther Ben Mabrouk has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Thomas H. Kauffmann
LMOPS, Université de Lorraine, 2 rue E. Belin, Metz, 54070, FRANCE
4 shared publications H. Aroui
3 shared publicationsMarc D. Fontana
University of Lorraine and Supélec, Laboratoire Matériaux Optiques, Photonique et Systèmes - EA 4423, Metz, France
3 shared publications- Anouar Hajjaji
Photovoltaic Laboratory, Research and Technology Centre of Energy (CRTEn), Hammam-Lif 2050, Tunisia
2 shared publications - Johannes Orphal
Institute of Meteorology and Climate Research, Karlsruhe Institute of Technology, Karlsruhe, Germany
2 shared publications - Amal Bouich
Laboratory of Advanced Materials and Process Engineering, Faculty of Sciences, Ibn Tofail University, Kenitra, Morocco
1 shared publication
Latest Publications
- 11 November 2025
- Published by Springer Nature in Modeling Earth Systems and Environment
- Vol. 12 (1) , 1-14
Photocatalytic degradation of diclofenac in water using new composite ZnO-modified smectite/kaolinite clay
- 11 November 2025
- Published by Springer Nature in Modeling Earth Systems and Environment
- Vol. 12 (1) , 1-14
Photocatalytic degradation of diclofenac in water using new composite ZnO-modified smectite/kaolinite clay
- Open Access
Electrodeposition of BiVO4 Nanoparticles on TiO2 Nanotubes: Characterization and Synergetic Photocatalytic Degradation Activity of Amido Black Dye
To enhance the photocatalytic performance of TiO2 nanotubes (NTs) for the degradation of Amido Black as an organic pollutant, electrodeposition of bismuth vanadate (BiVO4) nanostructures was successfully applied. The effect of electrodeposited BiVO4 (25 s, 50 s, 150 s, 250 s), followed by a thermal treatment on TiO2-NTs, was studied. The structures of the as-prepared samples were characterized by X-ray diffraction (XRD). Morphological behavior was investigated using Scanning Electron Microscopy (SEM) and Transmission Electron Microscopy (TEM), both coupled with EDX. Optical characterizations were performed using photoluminescence and diffuse reflectance spectroscopy. The BiVO4/TiO2 NTs sample with 50 s deposition time gave the highest photocatalytic performance for Amido Black degradation, 99.4% after 150 min under UV light. This result has been achieved due to the structure and the optical properties of the sample. The heterojunction of both catalysts showed the synergetic effect on the photocatalytic performance where they remained stable after five cycling runs. Furthermore, quenching tests were conducted and proved that superoxide radicals (O2•) are the main active species during photodegradation process.
Open AccessElectrodeposition of BiVO4 Nanoparticles on TiO2 Nanotubes: Characterization and Synergetic Photocatalytic Degradation Activity of Amido Black Dye
To enhance the photocatalytic performance of TiO2 nanotubes (NTs) for the degradation of Amido Black as an organic pollutant, electrodeposition of bismuth vanadate (BiVO4) nanostructures was successfully applied. The effect of electrodeposited BiVO4 (25 s, 50 s, 150 s, 250 s), followed by a thermal treatment on TiO2-NTs, was studied. The structures of the as-prepared samples were characterized by X-ray diffraction (XRD). Morphological behavior was investigated using Scanning Electron Microscopy (SEM) and Transmission Electron Microscopy (TEM), both coupled with EDX. Optical characterizations were performed using photoluminescence and diffuse reflectance spectroscopy. The BiVO4/TiO2 NTs sample with 50 s deposition time gave the highest photocatalytic performance for Amido Black degradation, 99.4% after 150 min under UV light. This result has been achieved due to the structure and the optical properties of the sample. The heterojunction of both catalysts showed the synergetic effect on the photocatalytic performance where they remained stable after five cycling runs. Furthermore, quenching tests were conducted and proved that superoxide radicals (O2•) are the main active species during photodegradation process.
- 1 August 2019
- Published by Elsevier in Materials Science in Semiconductor Processing
- Vol. 98, 131-139
Effect of electrophoresis time deposition of colloidal gold nanoparticles on inducing the crystallization of amorphous Si thin films
- 1 August 2019
- Published by Elsevier in Materials Science in Semiconductor Processing
- Vol. 98, 131-139
Effect of electrophoresis time deposition of colloidal gold nanoparticles on inducing the crystallization of amorphous Si thin films
- 1 November 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19300395,p. 1-4
Raman probe for the simultaneous measurement of anion concentration in mixtures of salt solutions
We propose to detect by Raman spectrometry the presence of several anions in mixtures of salt solutions and to measure simultaneously their respective concentrations. In this study we show how chemometric methods based on statistical analysis like Principal Components Analysis (PCA) and Partial Least Square Regression (PLSR) can be applied for the spectra treatment. Unlike current water probes often based on conductivity, our new Raman sensor is able to identify simultaneously and in one single measurement several anions such as NO 3 - , SO 4 2- , HPO 4 2- or Cl - sought for the water pollution monitoring. Moreover our sensor gives rise to reliable, accurate and fast measurement (a few seconds) and can therefore be very useful for in situ water quality control applications.
- 1 November 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19300395,p. 1-4
Raman probe for the simultaneous measurement of anion concentration in mixtures of salt solutions
We propose to detect by Raman spectrometry the presence of several anions in mixtures of salt solutions and to measure simultaneously their respective concentrations. In this study we show how chemometric methods based on statistical analysis like Principal Components Analysis (PCA) and Partial Least Square Regression (PLSR) can be applied for the spectra treatment. Unlike current water probes often based on conductivity, our new Raman sensor is able to identify simultaneously and in one single measurement several anions such as NO 3 - , SO 4 2- , HPO 4 2- or Cl - sought for the water pollution monitoring. Moreover our sensor gives rise to reliable, accurate and fast measurement (a few seconds) and can therefore be very useful for in situ water quality control applications.
- 1 November 2013
- Published by Elsevier in Journal of Quantitative Spectroscopy and Radiative Transfer
- Vol. 130, 273-283
Line-mixing effect on NH3 line intensities
- 1 November 2013
- Published by Elsevier in Journal of Quantitative Spectroscopy and Radiative Transfer
- Vol. 130, 273-283
Line-mixing effect on NH3 line intensities
- 11 September 2013
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 44 (11) , 1603-1608
Raman study of cation effect on sulfate vibration modes in solid state and in aqueous solutions
Raman spectra of potassium, sodium, and ammonium sulfates (K2SO4, Na2SO4, and (NH4)2SO4) are reported and analyzed. These sulfates have been investigated under two states: solid (anhydrous and hydrated) salts and aqueous solutions. The effects of monovalent ions (K+, Na+, and NH4+) and hydration on the position of Raman lines assigned to internal vibrations of sulfate anion SO42− are discussed. In solid salts, the line position of each Raman peak is shown to decrease with increasing radius of the cation. The main ν1 mode of sulfate molecule is particularly affected. It is emphasized that this sensitivity in solid sulfates vanishes in aqueous solutions. As a consequence, this mode can be probed by Raman spectroscopy as the main signature of SO42− to determine its concentration within a single calibration. Copyright © 2013 John Wiley & Sons, Ltd.
- 11 September 2013
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 44 (11) , 1603-1608
Raman study of cation effect on sulfate vibration modes in solid state and in aqueous solutions
Raman spectra of potassium, sodium, and ammonium sulfates (K2SO4, Na2SO4, and (NH4)2SO4) are reported and analyzed. These sulfates have been investigated under two states: solid (anhydrous and hydrated) salts and aqueous solutions. The effects of monovalent ions (K+, Na+, and NH4+) and hydration on the position of Raman lines assigned to internal vibrations of sulfate anion SO42− are discussed. In solid salts, the line position of each Raman peak is shown to decrease with increasing radius of the cation. The main ν1 mode of sulfate molecule is particularly affected. It is emphasized that this sensitivity in solid sulfates vanishes in aqueous solutions. As a consequence, this mode can be probed by Raman spectroscopy as the main signature of SO42− to determine its concentration within a single calibration. Copyright © 2013 John Wiley & Sons, Ltd.
- Open Access
- 26 June 2013
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 450
Abilities of Raman sensor to probe pollutants in water
- 26 June 2013
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 450
Open AccessAbilities of Raman sensor to probe pollutants in water
- 24 May 2013
- Published by Royal Society of Chemistry (RSC)
- p. 40-67
Raman spectroscopic sensors for inorganic salts
Raman sensors are more and more used for various applications. In particular they were recently used for in situ and real time monitoring of inorganic substances in aqueous solution in the sea, in tanks or in vicinity of industrial sites. Among several advantages they provide the identification of many species with a fairly good component resolution and the accurate determination of their concentration. Raman probes are based upon different data treatment of the Raman spectra. Two main methods are emphasized here. In the first method suitable for diluted salts with polyatomic anions, the Raman spectrum exhibits a large and well resolved peak used as the direct signature of a peculiar anion to be detected. Salts with monoatomic anions are studied via their indirect influence on the large OH stretching band of the water. The advantages and limitations of each method are discussed and illustrated with some examples derived from our own experience. The process giving the quantification in the analysis of the species is described, with a particular attention devoted to the data treatment within the calibration procedure. Analysis with lineshape treatment and chemometric methods are both reported and discussed. A comparison with different approaches reported in the literature is provided. Finally, the main devices used for in situ monitoring are briefly described.
- 24 May 2013
- Published by Royal Society of Chemistry (RSC)
- p. 40-67
Raman spectroscopic sensors for inorganic salts
Raman sensors are more and more used for various applications. In particular they were recently used for in situ and real time monitoring of inorganic substances in aqueous solution in the sea, in tanks or in vicinity of industrial sites. Among several advantages they provide the identification of many species with a fairly good component resolution and the accurate determination of their concentration. Raman probes are based upon different data treatment of the Raman spectra. Two main methods are emphasized here. In the first method suitable for diluted salts with polyatomic anions, the Raman spectrum exhibits a large and well resolved peak used as the direct signature of a peculiar anion to be detected. Salts with monoatomic anions are studied via their indirect influence on the large OH stretching band of the water. The advantages and limitations of each method are discussed and illustrated with some examples derived from our own experience. The process giving the quantification in the analysis of the species is described, with a particular attention devoted to the data treatment within the calibration procedure. Analysis with lineshape treatment and chemometric methods are both reported and discussed. A comparison with different approaches reported in the literature is provided. Finally, the main devices used for in situ monitoring are briefly described.
- 1 December 2011
- Published by Elsevier in Journal of Quantitative Spectroscopy and Radiative Transfer
- Vol. 112 (18) , 2750-2761
N2 and O2 pressure broadening and pressure shift in the 4ν2 band of 16O12C32S
- 1 December 2011
- Published by Elsevier in Journal of Quantitative Spectroscopy and Radiative Transfer
- Vol. 112 (18) , 2750-2761
N2 and O2 pressure broadening and pressure shift in the 4ν2 band of 16O12C32S