Mrinmoy Sarker Turja
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mrinmoy Sarker Turja has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Ki-Doo Kim
Department of Electronics Engineering, Kookmin University, Seoul 02707, Republic of Korea
3 shared publications - Tae-Ho Kwon
Department of Electronics Engineering, Kookmin University, Seoul 02707, Republic of Korea
3 shared publications - Hyoungkeun Kim
Korea I.T.S. Co., Ltd., Gangnam, Seoul 06373, Republic of Korea
1 shared publication - Monira Islam
Department of Electrical and Electronic Engineering, Khulna University of Engineering & Technology, Khulna, Bangladesh
1 shared publication Omar Faruque
Khulna University of Engineering & Technology
1 shared publication- Salah Uddin Yusuf
Khulna University of Engineering & Technology (KUET)
1 shared publication
Latest Publications
- Open Access
- 24 August 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (9) , 1067
Design and Validation of a Monte Carlo Method for the Implementation of Noninvasive Wearable Devices for HbA1c Estimation Considering the Skin Effect
To diagnose diabetes early or to maintain stable blood glucose levels in diabetics, blood glucose levels should be frequently checked. However, the only way to check blood glucose levels regularly is to use invasive methods, such as pricking the fingertip or using a minimally invasive patch. These invasive methods pose several problems, including being painful and potentially causing secondary infections. This study focuses on noninvasively measuring glycated hemoglobin (HbA1c) using PPG signals. In particular, the study relates to a method and a hardware design technology for removing noise that may be present in a PPG signal due to skin contact with a noninvasive HbA1c measurement device. The proposed HbA1c measurement device consists of the first sensor (PPG sensor) module including an optical barrier and the second sensor (cylindrical sensor) module for removing the skin effect. We have developed a Monte Carlo method to implement accurate, noninvasive HbA1c measurement by considering different skin properties among different subjects. Implementing this model in wearable devices will allow end users to not only monitor their glycated hemoglobin levels but also control diabetes with higher accuracy without needing any blood samples. This will be a groundbreaking advancement in modern wearable medical devices.
- 24 August 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (9) , 1067
Open AccessDesign and Validation of a Monte Carlo Method for the Implementation of Noninvasive Wearable Devices for HbA1c Estimation Considering the Skin Effect
To diagnose diabetes early or to maintain stable blood glucose levels in diabetics, blood glucose levels should be frequently checked. However, the only way to check blood glucose levels regularly is to use invasive methods, such as pricking the fingertip or using a minimally invasive patch. These invasive methods pose several problems, including being painful and potentially causing secondary infections. This study focuses on noninvasively measuring glycated hemoglobin (HbA1c) using PPG signals. In particular, the study relates to a method and a hardware design technology for removing noise that may be present in a PPG signal due to skin contact with a noninvasive HbA1c measurement device. The proposed HbA1c measurement device consists of the first sensor (PPG sensor) module including an optical barrier and the second sensor (cylindrical sensor) module for removing the skin effect. We have developed a Monte Carlo method to implement accurate, noninvasive HbA1c measurement by considering different skin properties among different subjects. Implementing this model in wearable devices will allow end users to not only monitor their glycated hemoglobin levels but also control diabetes with higher accuracy without needing any blood samples. This will be a groundbreaking advancement in modern wearable medical devices.
- Open Access
- 8 February 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (4) , 1406
EMD-Based Noninvasive Blood Glucose Estimation from PPG Signals Using Machine Learning Algorithms
Effective management of diabetes requires accurate monitoring of blood glucose levels. Traditional invasive methods for such monitoring can be cumbersome and uncomfortable for patients. In this study, we introduce a noninvasive approach to estimate blood glucose levels using photoplethysmography (PPG) signals. We have focused on blood glucose prediction using wrist PPG signals and explored various PPG waveform-based features, including AC to DC ratio (AC/DC) and intrinsic mode function (IMF)-based features derived from empirical mode decomposition (EMD). To the best of our knowledge, no studies have been found using EMD-based features to estimate blood glucose levels noninvasively. Additionally, feature importance-based selection has also been used to further improve the accuracy of the proposed model. Among the four machine learning algorithms considered in this study, CatBoost consistently outperformed XGBoost, LightGBM, and random forest across a wide number of features. The best performing model, CatBoost, achieved Pearson’s r of 0.96, MSE 0.08, score 0.92, and MAE 8.01 when considering the top 50 features selected from both PPG waveform-based features and IMF-based features. The p-values for all models were <0.001, indicating statistically significant correlations. Overall, this study provides valuable insights into the feasibility and effectiveness of noninvasive blood glucose monitoring using advanced machine learning techniques.- 8 February 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (4) , 1406
Open AccessEMD-Based Noninvasive Blood Glucose Estimation from PPG Signals Using Machine Learning Algorithms
Effective management of diabetes requires accurate monitoring of blood glucose levels. Traditional invasive methods for such monitoring can be cumbersome and uncomfortable for patients. In this study, we introduce a noninvasive approach to estimate blood glucose levels using photoplethysmography (PPG) signals. We have focused on blood glucose prediction using wrist PPG signals and explored various PPG waveform-based features, including AC to DC ratio (AC/DC) and intrinsic mode function (IMF)-based features derived from empirical mode decomposition (EMD). To the best of our knowledge, no studies have been found using EMD-based features to estimate blood glucose levels noninvasively. Additionally, feature importance-based selection has also been used to further improve the accuracy of the proposed model. Among the four machine learning algorithms considered in this study, CatBoost consistently outperformed XGBoost, LightGBM, and random forest across a wide number of features. The best performing model, CatBoost, achieved Pearson’s r of 0.96, MSE 0.08, score 0.92, and MAE 8.01 when considering the top 50 features selected from both PPG waveform-based features and IMF-based features. The p-values for all models were <0.001, indicating statistically significant correlations. Overall, this study provides valuable insights into the feasibility and effectiveness of noninvasive blood glucose monitoring using advanced machine learning techniques. - Open Access
- 12 March 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (6) , 3626
Noninvasive In Vivo Estimation of HbA1c Based on the Beer–Lambert Model from Photoplethysmogram Using Only Two Wavelengths
Glycated hemoglobin (HbA1c) is the most important factor in diabetes control. Since HbA1c reflects the average blood glucose level over the preceding three months, it is unaffected by a patient’s activity level or diet before a test. Noninvasive HbA1c measurement reduces both the pain and complications associated with fingertip piercing to collect blood. Photoplethysmography is helpful for measuring HbA1c without blood samples. Herein, only two wavelengths (615 and 525 nm) were used to estimate HbA1c noninvasively, where two different ratio calibrations were applied and their performances were compared to a work that used three wavelengths. For the fingertip type, the Pearson’s r values for HbA1c estimates were 0.896 and 0.905, considering the ratio calibrations for the blood vessel and whole finger models, respectively. Using another value (HbA1c) calibration in addition to the ratio calibrations, we could improve this performance such that the Pearson’s r values of the HbA1c levels were 0.929 and 0.930 for the blood vessel and whole finger models, respectively. In a previous study, using three wavelengths, the Pearson’s r values were 0.916 and 0.959 for the blood vessel and whole finger models, respectively. Here, the RCF of the SpO2 estimation was 0.986 when the SpO2 ratio calibration was applied, while in a previous study, the RCF values of the SpO2 estimation were 0.983 and 0.986 for the blood vessel and whole finger models, respectively. Thus, we have shown that HbA1c estimation using only two wavelengths has a comparable performance to previous studies.
- 12 March 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (6) , 3626
Open AccessNoninvasive In Vivo Estimation of HbA1c Based on the Beer–Lambert Model from Photoplethysmogram Using Only Two Wavelengths
Glycated hemoglobin (HbA1c) is the most important factor in diabetes control. Since HbA1c reflects the average blood glucose level over the preceding three months, it is unaffected by a patient’s activity level or diet before a test. Noninvasive HbA1c measurement reduces both the pain and complications associated with fingertip piercing to collect blood. Photoplethysmography is helpful for measuring HbA1c without blood samples. Herein, only two wavelengths (615 and 525 nm) were used to estimate HbA1c noninvasively, where two different ratio calibrations were applied and their performances were compared to a work that used three wavelengths. For the fingertip type, the Pearson’s r values for HbA1c estimates were 0.896 and 0.905, considering the ratio calibrations for the blood vessel and whole finger models, respectively. Using another value (HbA1c) calibration in addition to the ratio calibrations, we could improve this performance such that the Pearson’s r values of the HbA1c levels were 0.929 and 0.930 for the blood vessel and whole finger models, respectively. In a previous study, using three wavelengths, the Pearson’s r values were 0.916 and 0.959 for the blood vessel and whole finger models, respectively. Here, the RCF of the SpO2 estimation was 0.986 when the SpO2 ratio calibration was applied, while in a previous study, the RCF values of the SpO2 estimation were 0.983 and 0.986 for the blood vessel and whole finger models, respectively. Thus, we have shown that HbA1c estimation using only two wavelengths has a comparable performance to previous studies.
- 26 January 2023
- Published by Springer Nature
- p. 435-445
Efficient Malaria Cell Image Classification Using Deep Convolutional Neural Network
- 26 January 2023
- Published by Springer Nature
- p. 435-445
Efficient Malaria Cell Image Classification Using Deep Convolutional Neural Network