  • Open Access

    Comparison of Electron Density and Absorption Dose Values of Artificial Boluses as Tissue Substitutes

    by D. R. Putri, F. K. Hentihu, R. J. Stevenly, E. R. Putri

    According to the Skin Cancer Foundation (SCF), approximately 1.8 million new cases of Squamous Cell Carcinoma (SCC) were reported globally in 2023. Radiotherapy remains a common treatment modality for SCC. However, delivering the maximum dose directly to the skin surface is often impeded by the skin-sparing effect of high-energy photon and electron beams. To overcome this limitation, a bolus, a tissue-equivalent material, is applied to bring the dose closer to the surface. This study aims to evaluate the electron density values derived from CT images and the absorbed doses of boluses fabricated from three different materials: resin Lycal 1079 (a propylene glycol-based compound), silicone rubber (polydimethylsiloxane), and plasticine (a mixture of stearate salt and glycerin). Dosimetric measurements were conducted using 6 MV photon beams and 12 MeV electron beams. Image analysis was performed using ImageJ and Matlab softwares. The irradiation setup employed a Source-to-Surface Distance (SSD) of 100 cm and a 10 × 10 cm² field size. Relative Electron Density (RED) values obtained from ImageJ for the resin and silicone rubber boluses were 1.007 and 1.188, respectively, while Matlab yielded RED values of 1.094 for resin and 1.194 for silicone rubber. For the plasticine bolus, both software tools produced a consistent RED value of 1.101. The findings indicate that beam energy has a significant impact on the absorbed dose at various phantom depths. Furthermore, all bolus materials increased the absorbed dose compared to setups without a bolus. Among the three materials, the resin bolus exhibited the most favorable characteristics, with a RED value closely approximating that of breast and skin tissue, highlighting its potential as an effective and economical tissue-equivalent bolus for clinical radiotherapy applications.

  • Open Access

    Brain Tumor Segmentation in MR Images Using Swin Transformer

    by A. Nur, K. Nurhanafi, E. R. Putri

    Brain tumors are abnormal tissue growths in the brain. These brain tumors can have a negative impact on human health, one of which can interfere with brain functions such as vision, balance, and so on. Therefore, early detection needs to be done, one of which is by using medical imaging modalities, i.e., MRI. However, analyzing MRI scans requires careful observation and a high level of proficiency. Thus, medical image segmentation is required. Segmentation is important in medical image analysis as it allows medical experts to distinguish between abnormal and normal tissues. This study aims to determine the ability of the swin transformer architecture in segmenting brain tumor MR images. The image data used was BraTS 2021 data with a total of 1,250 images. The data were divided into three, i.e., training set, validation set, and testing set with a ratio of 70:15:15. Swin Transformer provided two main concepts, i.e., hierarchical feature maps and attention window shifts. The Swin Transformer initially was divided the image into small patches, which were then converted into vector form. After that, it was passed through W-MSA for local area and SW-MSA for cross window area. Next, multiple patches were merged into one, so that the image resolution gradually decreased, and then restored back to the original resolution. Based on this, the segmentation results were evaluated using a confusion matrix using DSC, IoU, and sensitivity metrics. The results of brain tumors MR image segmentation with Swin Transformer obtained evaluation values, i.e., 0.97313 for DSC, 0.94767 for IoU, and 0.96450 for sensitivity. It can be concluded that the Swin Tranformer can effectively segment brain tumor MR images.


  • Open Access

    Radiation Dose and Image Quality of Bladder Cancer Patients Analysis on Abdominal CT-Scan Examinations

    by R. Anthon, S. H. Intifadhah, E. R. Putri

    The bladder is a subperitoneal, hollow muscular organ that acts as areservoir for urine and located in the lower abdomen. Bladder cancer is one of health issues that can affect many people each year. Bladder cancer ranks as the 10th most common cancer worldwide. Early management includes cancer screening using abdominal CT-Scan. The objective of this study was to analyze the radiation dose received by patients and the image quality of patients underwent abdominal CT scans based on the Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) values obtained. Data analysis management, specifically using quantitative analysis techniques, involved observing 20 bladder cancer patients with a total of 2,653 images. The IndoseCT software was used for analyzing the radiation dose to patients, while the IndoQCT software was used for analyzing image quality in CT-Abdomen examinations based on Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) values. The results showed that the radiation dose received by patients during CT-Abdomen examinations was higher than the dose output by the device. The maximum dose output by the device (CTDIvol) was 50.10 mGy, and the minimum was 6.70 mGy, while the maximum dose received by patients (SSDE) was 53.34 mGy, and the minimum was 9.34 mGy. The image quality results for CT-Abdomen examinations based on SNR and CNR values indicated that the image quality obtained was adequate for diagnostic purposes.


  • Open Access

    Brain Tumor Segmentation on MR and CT Images Using Fuzzy C-Means and Active Contour Methods

    by M. Hamid, A. Mu'TI, S. H. Intifadhah, E. R. Putri

    A brain tumor is a dangerous brain disease that can attack anyone. It can be described as the abnormal growth of cells in or around the brain, leading to impaired brain function. The first step in diagnosing a brain tumor is to perform an MRI (Magnetic Resonance Imaging) scan. The research aims to analyze the segmentation results of brain tumor MRI and CT (Computed Tomography) images using the Fuzzy C-Means and Active Contour methods. The evaluation is based on ROC parameters, including accuracy, dice score, precision, and sensitivity. The methodology involves analyzing data from secondary image sources, using MATLAB for the segmentation process, and evaluating the results of image segmentation by radiologists. Four ROC measurements were used for each method. The segmentation evaluation results for MRI images show that the Fuzzy C-Means method achieved a precision of 0.92; sensitivity of 0.64; dice score of 0.76; and accuracy of 0.61. The Active Contour method, on the other hand, obtained a precision of 0.97; a sensitivity of 0.99; a dice score of 0.98; and an accuracy of 0.96. For CT images, the Fuzzy C-Means method yielded a precision of 0.72; sensitivity of 0.98; dice score of 0.83; and accuracy of 0.71. The Active Contour method obtained a precision of 0.96; a sensitivity of 0.95; a dice score of 0.96; and an accuracy of 0.92. These results indicate that the Active Contour method, especially with MRI images, provides better segmentation performance. In conclusion, the segmentation results from the Active Contour method can be used as additional information for doctors in diagnosing the presence of tumors.

  • Open Access

    Estimation of Organ Dose, Effective Dose, and Cancer Risk in Abdominal CT Scan Patients

    by S. S. Putri, S. H. Intifadhah, E. R. Putri

    Computed tomography scan (CT scan) is a modality that is used to diagnose diseases inside the human body. In the scanning process, the patient will receive radiation from the CT scanner, so that it is necessary to calculate the amount of radiation dose. The purpose of this study was to determine the organ dose, effective dose, and cancer risk received by abdominal examination patients. Data taken from the results of abdominal examination patients at Radiology Installation of A.W. Sjahranie Regional Hospital Samarinda using 16-slice CT scan modality GE BRIVO type D3161T. The data collected included 150 patients, both female and male, with ages ranging from 15 to 79 years. Dosimetry parameters taken from CT scan results are the exposure factor (kV, mAs), scan length, computed tomography dosimetry indeks volume (CTDIvol), and dose length product (DLP) of the patient. CTDIvol and DLP of the patient are used to calculate the organ dose, effective dose, and cancer risk values of abdominal CT scan patients. Then the effective dose value received by the abdominal CT scan examination patient is compared with the Nuclear Energy Regulatory Agency of Indonesia (BAPETEN) standard based on the CTDIvol and DLP values of the patient, and also compared with the International Commission Radiological Protection (ICRP) standard. Based on the results of organ dose estimation calculations, the average value of the stomach is 0.82 mSv, the gonads are 0.54 mSv, and the bladder is 0.28 mSv. Meanwhile, the average value of effective dose received by abdominal examination patients is 5.28 mSv with an average cancer risk of 0.029 %. Based on the CTDIvol and DLP values of the patients, the 3rd quartile values of the patients were 8.25 mGy and 413.84 mGy.cm. This value is still below the value recommended by BAPETEN when viewed from the 2021 Diagnostic Reference Level (DRL) guidelines. The effective dose received by one patient exceeded the standard set by the ICRP. Meanwhile, the cancer risk received by patients is still in a low percentage.


  • Open Access

    Comparison of Cut Out Transmission Variations on a 10x10 cm2 Applicator for Linac Electron Beam

    by Alisya Oktafianingrum, Robert Janssen Stevenly, Pratiwi Sri Wardani, Erlinda Ratnasari Putri

    Comparison of Cut Out Transmission Variations on a 10x10 cm2 Applicator for Linac Electron Beam

  • Open Access

    Improving the Quality of CT Images of Stroke Patients Using the SSDE and K-Means Segmentation in the Radiology Installation of RSUD A.W. Sjahranie Samarinda

    by Erlinda Ratnasari Putri, Fransiska Lipa Payon, Ronel Arida Missinychrista, Devina Rayzy Perwitasari Sutaji Putri, Pratiwi Sri Wardani, Kadek Subagiada

    Stroke examination using a CT scan is a technique that produces 3D brain images without having to do surgery. The purpose of this study was to determine the dose received by each patient who underwent a CT-scan procedure and to improve the image quality of the results. Optimization of the dose for each patient is based on a comparison between the calculated SSDE value and the DRL in the form of CTDIvol and DLP, which are implemented in Indonesia. Improving the quality of CT-Scan images through digital processing using the segmentation method to determine the stroke area. The method used is K-Means segmentation. The results obtained for the SSDE value are the dose received by the patient which is higher than the dose issued by the device or the value. However, the SSDE, CTDIvol, and DLP values are still below the DRL standard range set by BAPETEN, so they are still within the safe inspection threshold. The average CTDIvol value, which is the output dose value of the device from 22 patients, was 41.84 mGy and the 75th percentile value was 42.7 mGy. The average DLP value is 1054.08 mGy.cm and the 75th percentile value of the DLP value is 964.13 mGy.cm. The average value of the SSDE value which is the value of the dose received by the patient is 43.39 mGy and the 75th percentile value is 42.440 mGy. Based on these results, the value of the dose received by the patient is higher than the value of the dose issued by the device. Segmentation using the K-Means method with the number of clusters k = 3 produces an accuracy of 86.3%. This means that the patient receives a dose of CT-Scan radiation within safe limits and his image can be processed properly, as evidenced by the high success of the segmentation process.


  • Open Access

    Determination of the Diagnostic Reference Level (DRL) in Samarinda Hospitals

    by R. Jannah, R. Munir, E. R. Putri

    The diagnostic reference level (DRL) is a form of investigative level used as a tool to help optimize protection to radiation exposure for diagnostic and interventional procedures. The purpose of this study was to determine the local DRL values for the examination of the abdomen, thorax, and head at radiology installations. The modality used was 128-slice CT scan. The numbers of patients whose data were used were 200 for abdominal examinations, 160 for thoracic examinations, and 100 for head examinations. Overall, the total patient whose data was used was 460. Data processing in this study was carried out with a quantitative analysis technique, namely descriptive statistics. This analysis technique used secondary data obtained from the results of recaptures or archival books for examination of the abdomen, thorax, and head. Data processing was carried out with a measure of diversity through the calculation of the third quartile in the data distribution. It was assumed that 75 % of patients performed examinations with a common diagnosis. The results of these calculations are visualized in the form of graphs of the relationship of computed tomography dose index volume (CTDIvol) with the number of patients and a graph of the relationship of dose length product (DLP) with the number of patients. In the abdominal examination, a CTDIvol of 12 mGy and a DLP of 1545.5 mGy·cm. In the thoracic examination, a CTDIvol of 11 mGy and a DLP of 903 mGy·cm were obtained. For the head examination, a CTDIvol of 34.25mGy and a DLP of 2190.25 mGy·cm were obtained. The conclusion obtained from this study is that the DRLs are relatively low, but they still need to be optimized by medical physicists.


  • Open Access

    Analysis of Radiation Exposure Level on Linen and Other Objects in Patient Rooms at Nuclear Medicine Installation

    by A. Putri, R. Zurma, R. Munir, E. R. Putri

    Analysis of radiation contamination levels has been carried out using an Atomtex surveymeter in the patient rooms after thyroid cancer ablation therapy, in the Nuclear Medicine Installation, Abdoel Wahab Sjahranie Hospital. This study aims to measure the level of radiation exposure based on the rate of radiation exposure and radiation contamination of objects in the patient rooms after ablation therapy, and to find out how long linen can be washed since the first measurement. Data collection was carried out once a week, on the same weekday, for five weeks for objects in the patient rooms by using the surveymeter at a fixed distances from the objects’ surfaces. Radiation contamination measurements for linen items were carried out for 3 d by aiming the surveymeter to container containing linen items from certain distances. Based on this study, the level of radiation exposure obtained is categorized as low because the value range is below 10 μSv/h. The radiation contamination for some objects are categorized as low-level exposure because the value is less than 3.7 Bq/cm2. Other objects tend to be in the moderate-level category because the value is more than 3.7 Bq/cm2 and less than 37 Bq/cm2. The values obtained refer to the standard issued by BATAN. It can be concluded that the patient rooms in the Nuclear Medicine Installation of Abdoel Wahab Sjahranie Hospital are safe.