Carl Petter Skaar Kulseng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Carl Petter Skaar Kulseng has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Silje Sommerfelt
Division of Obstetrics and Gynecology Akershus University Hospital Lørenskog Norway
4 shared publicationsAnne Eskild
Department of Obstetrics and Gynecology, Akershus University Hospital, Nordbyhagen, 1478, Norway; Institute of Clinical Medicine, University of Oslo, P.O. Box 1171, Blindern, 0318, Oslo, Norway
3 shared publicationsKjell-Inge Gjesdal
Sunnmøre MR-Klinikk, Langelandsvegen 15, 6010, Ålesund, Norway; Department of Diagnostic Imaging, Akershus University Hospital, Nordbyhagen, 1478, Norway
3 shared publicationsVigdis Hillestad
Department of Diagnostic Imaging, Akershus University Hospital, Nordbyhagen, 1478, Norway
3 shared publications- Anne Eskild
Department of Obstetrics and Gynecology Akershus University Hospital Lørenskog Norway
2 shared publications Helene Fjeldvik Peterson
Department of Obstetrics and Gynecology, Akershus University Hospital, Nordbyhagen, 1478, Norway; Institute of Clinical Medicine, University of Oslo, P.O. Box 1171, Blindern, 0318, Oslo, Norway
2 shared publications
Latest Publications
- Open Access
- 14 April 2025
- Published by Wiley in Acta Obstetricia et Gynecologica Scandinavica
- Vol. 104 (6) , 1135-1142
Placental size and umbilical vein volume blood flow
Introduction: The fetus receives oxygen and nutrition from the placenta through the umbilical vein. There is a large variation in placental size and placental size relative to fetal size (placental–fetal ratio). We studied whether placental size or placental–fetal ratio is related to blood flow in the umbilical vein.Material and Methods: We performed a prospective study at Akershus University Hospital in Norway and a total of 73 women were examined in gestational weeks 27 and 37. Fifty‐six women were examined at both time points. B‐mode ultrasound and Doppler ultrasonography were used to measure the umbilical vein volume blood flow per minute. Magnetic resonance imaging was used to measure placental and fetal volume. Pearson's and Spearman's correlation coefficients were applied for estimations of associations.Results: In gestational week 27, the umbilical vein volume blood flow was positively correlated with fetal size (Pearson's correlation coefficient r = 0.372, p = 0.003, and Spearman's correlation coefficient r = 0.384, p = 0.002), but not with placental size (Pearson's r = 0.130, p = 0.317, and Spearman's r = − 0.53, p = 0.687) or placental–fetal ratio (Pearson's r = − 0.61, p = 0.641, and Spearman's r = − 0.218, p = 0.092). In gestational week 37, we found positive correlations of the umbilical vein volume blood flow with fetal size (Pearson's r = 0.428, p = p p = 0.001, and Spearman's r = 0.643, p p = 0.066, and Spearman's r = 0.266, p = 0.028).Conclusions: A large placenta and a high placental–fetal ratio are associated with increased umbilical vein blood flow.
- 14 April 2025
- Published by Wiley in Acta Obstetricia et Gynecologica Scandinavica
- Vol. 104 (6) , 1135-1142
Open AccessPlacental size and umbilical vein volume blood flow
Introduction: The fetus receives oxygen and nutrition from the placenta through the umbilical vein. There is a large variation in placental size and placental size relative to fetal size (placental–fetal ratio). We studied whether placental size or placental–fetal ratio is related to blood flow in the umbilical vein.Material and Methods: We performed a prospective study at Akershus University Hospital in Norway and a total of 73 women were examined in gestational weeks 27 and 37. Fifty‐six women were examined at both time points. B‐mode ultrasound and Doppler ultrasonography were used to measure the umbilical vein volume blood flow per minute. Magnetic resonance imaging was used to measure placental and fetal volume. Pearson's and Spearman's correlation coefficients were applied for estimations of associations.Results: In gestational week 27, the umbilical vein volume blood flow was positively correlated with fetal size (Pearson's correlation coefficient r = 0.372, p = 0.003, and Spearman's correlation coefficient r = 0.384, p = 0.002), but not with placental size (Pearson's r = 0.130, p = 0.317, and Spearman's r = − 0.53, p = 0.687) or placental–fetal ratio (Pearson's r = − 0.61, p = 0.641, and Spearman's r = − 0.218, p = 0.092). In gestational week 37, we found positive correlations of the umbilical vein volume blood flow with fetal size (Pearson's r = 0.428, p = p p = 0.001, and Spearman's r = 0.643, p p = 0.066, and Spearman's r = 0.266, p = 0.028).Conclusions: A large placenta and a high placental–fetal ratio are associated with increased umbilical vein blood flow.
- Open Access
- 5 March 2025
- Published by Wiley in Acta Obstetricia et Gynecologica Scandinavica
- Vol. 104 (5) , 913-921
The association of placental to fetal ratio with pregnancy duration
Introduction: Our objective was to study the association of placental size, fetal size, and placental size relative to fetal size (placental to fetal ratio) at gestational week 27 with time to spontaneous delivery.Material and Methods: We included 100 pregnancies in a follow‐up study from gestational week 27 until spontaneous delivery. Placental and fetal volume (in cm3) were measured at gestational week 27 by magnetic resonance imaging (MRI), and the association of placental to fetal ratio (placental volume/fetal volume) with delivery after spontaneous onset of labor was estimated as hazard ratios (HR) by applying Cox regression models. Pregnancies with deliveries after planned cesarean section or induction of labor provided follow‐up time until these events. An HR lower than 1.0 indicates decreased risk of spontaneous delivery.Results: Mean placental volume was 532 cm3 (SD 136 cm3) at gestational week 27, and fetal volume was 961 cm3 (SD 112 cm3). This yielded a mean placental to fetal ratio of 0.55 (SD 0.12). The HR of spontaneous delivery decreased with increasing placental to fetal ratio (HR 0.013 (95% CI: 0.001–0.121), Wald statistic 14.704 (p < 0.001)), indicating a longer duration of pregnancy with a higher placental to fetal ratio at gestational week 27. The HR of spontaneous delivery also decreased with increasing placental size, but the association was less prominent than the HR associated with placental to fetal ratio (HR 0.997 [95% CI: 0.995–0.999], Wald statistic 7.638 [p = 0.006]). We estimated no association with fetal size (HR 1.001 [95% CI 0.999–1.003], Wald statistic 1.728 [p = 0.189]).Conclusions: Our findings suggest that the placental to fetal ratio at gestational week 27 may be an indicator of the remaining duration of pregnancy until the onset of spontaneous labor.
- 5 March 2025
- Published by Wiley in Acta Obstetricia et Gynecologica Scandinavica
- Vol. 104 (5) , 913-921
Open AccessThe association of placental to fetal ratio with pregnancy duration
Introduction: Our objective was to study the association of placental size, fetal size, and placental size relative to fetal size (placental to fetal ratio) at gestational week 27 with time to spontaneous delivery.Material and Methods: We included 100 pregnancies in a follow‐up study from gestational week 27 until spontaneous delivery. Placental and fetal volume (in cm3) were measured at gestational week 27 by magnetic resonance imaging (MRI), and the association of placental to fetal ratio (placental volume/fetal volume) with delivery after spontaneous onset of labor was estimated as hazard ratios (HR) by applying Cox regression models. Pregnancies with deliveries after planned cesarean section or induction of labor provided follow‐up time until these events. An HR lower than 1.0 indicates decreased risk of spontaneous delivery.Results: Mean placental volume was 532 cm3 (SD 136 cm3) at gestational week 27, and fetal volume was 961 cm3 (SD 112 cm3). This yielded a mean placental to fetal ratio of 0.55 (SD 0.12). The HR of spontaneous delivery decreased with increasing placental to fetal ratio (HR 0.013 (95% CI: 0.001–0.121), Wald statistic 14.704 (p < 0.001)), indicating a longer duration of pregnancy with a higher placental to fetal ratio at gestational week 27. The HR of spontaneous delivery also decreased with increasing placental size, but the association was less prominent than the HR associated with placental to fetal ratio (HR 0.997 [95% CI: 0.995–0.999], Wald statistic 7.638 [p = 0.006]). We estimated no association with fetal size (HR 1.001 [95% CI 0.999–1.003], Wald statistic 1.728 [p = 0.189]).Conclusions: Our findings suggest that the placental to fetal ratio at gestational week 27 may be an indicator of the remaining duration of pregnancy until the onset of spontaneous labor.
- Open Access
- 28 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 12 (1) , 283
Detecting Small Anatomical Structures in 3D Knee MRI Segmentation by Fully Convolutional Networks
Accurately identifying the pixels of small organs or lesions from magnetic resonance imaging (MRI) has a critical impact on clinical diagnosis. U-net is the most well-known and commonly used neural network for image segmentation. However, the small anatomical structures in medical images cannot be well recognised by U-net. This paper explores the performance of the U-net architectures in knee MRI segmentation to find a relative structure that can obtain high accuracies for both small and large anatomical structures. To maximise the utilities of U-net architecture, we apply three types of components, residual blocks, squeeze-and-excitation (SE) blocks, and dense blocks, to construct four variants of U-net, namely U-net variants. Among these variants, our experiments show that SE blocks can improve the segmentation accuracies of small labels. We adopt DeepLabv3plus architecture for 3D medical image segmentation by equipping SE blocks based on this discovery. The experimental results show that U-net with SE block achieves higher accuracy in parts of small anatomical structures. In contrast, DeepLabv3plus with SE block performs better on the average dice coefficient of small and large labels.
- 28 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 12 (1) , 283
Open AccessDetecting Small Anatomical Structures in 3D Knee MRI Segmentation by Fully Convolutional Networks
Accurately identifying the pixels of small organs or lesions from magnetic resonance imaging (MRI) has a critical impact on clinical diagnosis. U-net is the most well-known and commonly used neural network for image segmentation. However, the small anatomical structures in medical images cannot be well recognised by U-net. This paper explores the performance of the U-net architectures in knee MRI segmentation to find a relative structure that can obtain high accuracies for both small and large anatomical structures. To maximise the utilities of U-net architecture, we apply three types of components, residual blocks, squeeze-and-excitation (SE) blocks, and dense blocks, to construct four variants of U-net, namely U-net variants. Among these variants, our experiments show that SE blocks can improve the segmentation accuracies of small labels. We adopt DeepLabv3plus architecture for 3D medical image segmentation by equipping SE blocks based on this discovery. The experimental results show that U-net with SE block achieves higher accuracy in parts of small anatomical structures. In contrast, DeepLabv3plus with SE block performs better on the average dice coefficient of small and large labels.
- Open Access
- 30 November 2015
- Published by OsloMet - Oslo Metropolitan University in Radiography Open
- Vol. 2 (1) , 91-98
Positronemisjonstomografi (PET) i Norge
Positronemisjonstomografi (PET) er en bildediagnostisk undersøkelse med et stort klinisk potensiale [1]. Det er forventet et enormt behov for PET-undersøkelser i tiden fremover. Rapporten Estimering av behovet for PET/CT i 2020 på regionalt nivå [2] utarbeidet av Kunnskapssenteret på vegne av Nasjonalt råd for kvalitet og prioritering i helsetjenesten stipulerte at det vil være behov for opptil 14 slike scannere innen 2020. Fagmiljøet ser på utredning av cancer pulm, colorectal cancer, cancer prostata, lymfomer og cancer mammae som de viktigste indikasjonene for PET-undersøkelser i fremtiden. Det er forøvrig en relativt kostbar teknologi. En enkelt skanner koster omlag 20 millioner kroner. I tillegg kreves en syklotron for produksjon av radioaktivt materiale 25-35 millioner kroner, og den totale årlige driftsutgiften er beregnet til 16 – 17 millioner (Dkr) [3]. For å betjene en PET-scanner kreves radioaktive isotoper som må produseres i en syklotron. GE Healthcare produserer og forsyner de fleste PET-sentrene i Norge med radioaktive isotoper fra Norsk medisinsk syklotronsenter i Oslo. Dette krever nøye koordinering og er driftsøkonomisk kostbart. Haukeland Universitetssykehus i Bergen importerte i begynnelsen isotoper fra Oslo, men har nå tilgang til egen syklotron. Hensikten med denne fagartikkelen er å kartlegge historikken, dagens status og fremtidsplaner for aktiviteten ved de norske PET avdelingene.
- 30 November 2015
- Published by OsloMet - Oslo Metropolitan University in Radiography Open
- Vol. 2 (1) , 91-98
Open AccessPositronemisjonstomografi (PET) i Norge
Positronemisjonstomografi (PET) er en bildediagnostisk undersøkelse med et stort klinisk potensiale [1]. Det er forventet et enormt behov for PET-undersøkelser i tiden fremover. Rapporten Estimering av behovet for PET/CT i 2020 på regionalt nivå [2] utarbeidet av Kunnskapssenteret på vegne av Nasjonalt råd for kvalitet og prioritering i helsetjenesten stipulerte at det vil være behov for opptil 14 slike scannere innen 2020. Fagmiljøet ser på utredning av cancer pulm, colorectal cancer, cancer prostata, lymfomer og cancer mammae som de viktigste indikasjonene for PET-undersøkelser i fremtiden. Det er forøvrig en relativt kostbar teknologi. En enkelt skanner koster omlag 20 millioner kroner. I tillegg kreves en syklotron for produksjon av radioaktivt materiale 25-35 millioner kroner, og den totale årlige driftsutgiften er beregnet til 16 – 17 millioner (Dkr) [3]. For å betjene en PET-scanner kreves radioaktive isotoper som må produseres i en syklotron. GE Healthcare produserer og forsyner de fleste PET-sentrene i Norge med radioaktive isotoper fra Norsk medisinsk syklotronsenter i Oslo. Dette krever nøye koordinering og er driftsøkonomisk kostbart. Haukeland Universitetssykehus i Bergen importerte i begynnelsen isotoper fra Oslo, men har nå tilgang til egen syklotron. Hensikten med denne fagartikkelen er å kartlegge historikken, dagens status og fremtidsplaner for aktiviteten ved de norske PET avdelingene.
- Open Access
- 30 November 2015
- Published by OsloMet - Oslo Metropolitan University in Radiography Open
- Vol. 2 (1) , 1-14
Effective doses to staff and dose rates emitted from patients undergoing positron emission tomography utilizing 18F- Fluorodeoxglucose
IntroductionThe purpose of this two--folded quantitative study was to determine the radiation doses received by staff during 2014 at the PET--department at St. Olavs Hospital in Trondheim, Norway. Although studies show that the doses received by staff performing such examinations are far beneath the limits set by regulation, there was a need to determine how much radiation the staff at this clinic actually was exposed to. We investigated in detail both dose rates emitted by 18 F from different parts of the body to the surroundings along with effective doses to staff during 2014.MethodPart one - Dose rates from 20 patients undergoing FDG-PET/CT--scans were measured with dosimeter RadEye B20 (Thermo Scientific, USA) from five measuring points at three different stages of a standard whole body PET-scan utilizing 18 F-FDG.Part two - Effective doses to five radiographers and four bioengineers were registered daily during 2014. The effective dose measurements were done daily by the staff with personal dosimeter RadEye EPD MK2+ (Thermo Scientific, USA). The dosimeter was worn at chest level. The automatic injector Medrad Intego (Bayer, Germany) administrate the radioactive doses.ResultsPart one - Dose rates emitted from different parts of patients show significant differences. The highest dose rate was measured from the head and sternum of the patients. The knees emit the least dose rate of all body parts and was considerably lower from one meterdistance.Part two - The average effective doses were far below the recommended limits for occupational radiation. The total average effective dose per member of staff was 0.13 mSv in 2014 and the daily average dose was 4.91 μSv/day.ConclusionPart one - 18 F-FDG showed irregular distribution in the body, the lowest dose rates originated from the lower extremities and reflects the metabolism of glucose in the body at rest.Part two - We found significant differences between staff working with both CT and the radioisotope injection compared to the staff working solely with one of these tasks. Nevertheless, all effective- doses were safely within the guideline limits for occupational radiation.
- 30 November 2015
- Published by OsloMet - Oslo Metropolitan University in Radiography Open
- Vol. 2 (1) , 1-14
Open AccessEffective doses to staff and dose rates emitted from patients undergoing positron emission tomography utilizing 18F- Fluorodeoxglucose
IntroductionThe purpose of this two--folded quantitative study was to determine the radiation doses received by staff during 2014 at the PET--department at St. Olavs Hospital in Trondheim, Norway. Although studies show that the doses received by staff performing such examinations are far beneath the limits set by regulation, there was a need to determine how much radiation the staff at this clinic actually was exposed to. We investigated in detail both dose rates emitted by 18 F from different parts of the body to the surroundings along with effective doses to staff during 2014.MethodPart one - Dose rates from 20 patients undergoing FDG-PET/CT--scans were measured with dosimeter RadEye B20 (Thermo Scientific, USA) from five measuring points at three different stages of a standard whole body PET-scan utilizing 18 F-FDG.Part two - Effective doses to five radiographers and four bioengineers were registered daily during 2014. The effective dose measurements were done daily by the staff with personal dosimeter RadEye EPD MK2+ (Thermo Scientific, USA). The dosimeter was worn at chest level. The automatic injector Medrad Intego (Bayer, Germany) administrate the radioactive doses.ResultsPart one - Dose rates emitted from different parts of patients show significant differences. The highest dose rate was measured from the head and sternum of the patients. The knees emit the least dose rate of all body parts and was considerably lower from one meterdistance.Part two - The average effective doses were far below the recommended limits for occupational radiation. The total average effective dose per member of staff was 0.13 mSv in 2014 and the daily average dose was 4.91 μSv/day.ConclusionPart one - 18 F-FDG showed irregular distribution in the body, the lowest dose rates originated from the lower extremities and reflects the metabolism of glucose in the body at rest.Part two - We found significant differences between staff working with both CT and the radioisotope injection compared to the staff working solely with one of these tasks. Nevertheless, all effective- doses were safely within the guideline limits for occupational radiation.