Xiao Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xiao Yang has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Baoliang Wang
State Key Laboratory of Industrial Control Technology, College of Control Science and Engineering, Zhejiang University, Hangzhou, China
1 shared publication - Haifeng Ji
State Key Laboratory of Industrial Control Technology, College of Control Science and Engineering, Zhejiang University, Hangzhou, China
1 shared publication - Huajun Li
School of Automation, Hangzhou Dianzi University, Hangzhou, China
1 shared publication
Latest Publications
- Open Access
Distributed Optical Measurement System for Plate Fin Heat Exchanger
The acquirement of the flow information in plate-fin heat exchanger (PFHE) is limited by its metal structure and complex flow condition. This work develops a new distributed optical measurement system to obtain flow information and boiling intensity. The system utilizes numerous optical fibers installed at the surface of the PFHE to detect optical signals. The attenuation and fluctuation of the signals reflect the variation of the gas-liquid interfaces and can be further used to estimate the boiling intensity. Practical experiments of flow boiling in PFHE with different heating fluxes have been carried out. The results verify that the measurement system can obtain the flow condition. Meanwhile, according to the results, the boiling development in PFHE can be divided into four stages with the increase in the heating flux, including the unboiling stage, initiation stage, boiling developing stage, and fully developed stage.
Open AccessDistributed Optical Measurement System for Plate Fin Heat Exchanger
The acquirement of the flow information in plate-fin heat exchanger (PFHE) is limited by its metal structure and complex flow condition. This work develops a new distributed optical measurement system to obtain flow information and boiling intensity. The system utilizes numerous optical fibers installed at the surface of the PFHE to detect optical signals. The attenuation and fluctuation of the signals reflect the variation of the gas-liquid interfaces and can be further used to estimate the boiling intensity. Practical experiments of flow boiling in PFHE with different heating fluxes have been carried out. The results verify that the measurement system can obtain the flow condition. Meanwhile, according to the results, the boiling development in PFHE can be divided into four stages with the increase in the heating flux, including the unboiling stage, initiation stage, boiling developing stage, and fully developed stage.