Massimo Corain
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Massimo Corain has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Umberto Lavagnolo
Hand Surgery Unit, University Hospital of Verona (AOUI), Italy
2 shared publications Andrea Colombo
University Hospital of Verona (AOUI), Italy
1 shared publicationAndrea Sbarbati
Department of Neurological, Biomedical and Movement Sciences, Section of Anatomy and Histology, University of Verona, Italy
1 shared publicationAnna Andrioli
Department of Neurological, Biomedical and Movement Sciences, Section of Anatomy and Histology, University of Verona, Italy
1 shared publication- Filippo Pantaleoni
Department of Hand Surgery and Microsurgery, University Hospital of Modena, Modena, Italy
1 shared publication - Giovanna Petrella
Department of Hand Surgery and Microsurgery, University of Modena and Reggio Emilia, Policlinico di Modena, Largo del Pozzo 71, Modena, 41125, Italy
1 shared publication
Latest Publications
- 9 October 2026
- Published by SAGE Publications in HAND
Morpho-histological Analysis of the Ultrastructure of the Dupuytren Cord Subjected to Progressive Distraction Using an External Fixator
Background: This study aimed to provide a detailed morphological and ultrastructural characterization of Dupuytren disease cords in advanced stages, with particular attention to the effects of progressive mechanical distraction on extracellular matrix organization and tissue architecture. Methods: Six patients with stage IV Dupuytren disease affecting the fifth ray were included. Three underwent treatment with a distractible angular external fixator followed by open fasciectomy, while 3 controls received open fasciectomy alone. Excised cords were analyzed by light microscopy and scanning electron microscopy, with additional morphometric assessment of collagen organization. Results: Distracted samples showed increased cellularity, enhanced fascicular definition, and greater peripheral vascularization. At ultrastructural level, a more regular and modular arrangement of collagen was observed, with thicker and more widely spaced low-density regions compared with controls. Quantitative analysis confirmed a significant increase in thickness (9.23 ± 0.91 µm vs 7.33 ± 0.75 µm; P = .041) and spacing (21.3 ± 2.4 µm vs 13.4 ± 1.7 µm; P = .009), alongside a reduced linear fraction of these regions (52.4% ± 2.3% vs 59.5% ± 3.2%; P = .032). Conclusions: Progressive distraction induces substantial remodeling of Dupuytren disease cords, resulting in a more cellular and structurally organized extracellular matrix. These findings suggest that mechanical stimulation contributes not only to contracture correction but also to modification of the underlying fibrotic architecture, potentially improving surgical handling and providing a more favorable structural substrate for subsequent surgical intervention.
- 9 October 2026
- Published by SAGE Publications in HAND
Morpho-histological Analysis of the Ultrastructure of the Dupuytren Cord Subjected to Progressive Distraction Using an External Fixator
Background: This study aimed to provide a detailed morphological and ultrastructural characterization of Dupuytren disease cords in advanced stages, with particular attention to the effects of progressive mechanical distraction on extracellular matrix organization and tissue architecture. Methods: Six patients with stage IV Dupuytren disease affecting the fifth ray were included. Three underwent treatment with a distractible angular external fixator followed by open fasciectomy, while 3 controls received open fasciectomy alone. Excised cords were analyzed by light microscopy and scanning electron microscopy, with additional morphometric assessment of collagen organization. Results: Distracted samples showed increased cellularity, enhanced fascicular definition, and greater peripheral vascularization. At ultrastructural level, a more regular and modular arrangement of collagen was observed, with thicker and more widely spaced low-density regions compared with controls. Quantitative analysis confirmed a significant increase in thickness (9.23 ± 0.91 µm vs 7.33 ± 0.75 µm; P = .041) and spacing (21.3 ± 2.4 µm vs 13.4 ± 1.7 µm; P = .009), alongside a reduced linear fraction of these regions (52.4% ± 2.3% vs 59.5% ± 3.2%; P = .032). Conclusions: Progressive distraction induces substantial remodeling of Dupuytren disease cords, resulting in a more cellular and structurally organized extracellular matrix. These findings suggest that mechanical stimulation contributes not only to contracture correction but also to modification of the underlying fibrotic architecture, potentially improving surgical handling and providing a more favorable structural substrate for subsequent surgical intervention.
- 18 January 2026
- Published by SAGE Publications in HAND
- Vol. 21 (10) , 1668-1675
The Adaptive Proximal Scaphoid Implant: Long-Term Follow-Up
Background: Scaphoid proximal pole fracture with avascular necrosis is a surgical challenge, particularly in patients with high functional demand. An option is the pyrocarbon adaptive proximal scaphoid implant (APSI), replacing the necrotic proximal pole. Methods: A long-term follow-up study of the early cases treated in our department was conducted. Thirty-six patients with a median follow-up time of 19 years (range, 11-25) were included in the analysis, performing clinical and radiological evaluations. Results: Clinically, significant improvements were observed in mean pain Numeric Rating Scale (from 6.8 [SD 2.1] to 2 [2]), range of motion, grip strength measured with the Jamar dynamometer (from 18 [8] kg to 24 [9] kg), Disabilities of the Arm, Shoulder, and Hand score (from 66 [6.5] to 13.7 [6.4]), and Patient-Rated Wrist Evaluation score (from 73 [10] to 28 [12]). Radiographs showed good implant stability. No patient required implant removal. Conclusion: The APSI prosthesis proves effective long term in relieving pain, improving function, and preventing carpal collapse through stable biomechanical integration.
- 18 January 2026
- Published by SAGE Publications in HAND
- Vol. 21 (10) , 1668-1675
The Adaptive Proximal Scaphoid Implant: Long-Term Follow-Up
Background: Scaphoid proximal pole fracture with avascular necrosis is a surgical challenge, particularly in patients with high functional demand. An option is the pyrocarbon adaptive proximal scaphoid implant (APSI), replacing the necrotic proximal pole. Methods: A long-term follow-up study of the early cases treated in our department was conducted. Thirty-six patients with a median follow-up time of 19 years (range, 11-25) were included in the analysis, performing clinical and radiological evaluations. Results: Clinically, significant improvements were observed in mean pain Numeric Rating Scale (from 6.8 [SD 2.1] to 2 [2]), range of motion, grip strength measured with the Jamar dynamometer (from 18 [8] kg to 24 [9] kg), Disabilities of the Arm, Shoulder, and Hand score (from 66 [6.5] to 13.7 [6.4]), and Patient-Rated Wrist Evaluation score (from 73 [10] to 28 [12]). Radiographs showed good implant stability. No patient required implant removal. Conclusion: The APSI prosthesis proves effective long term in relieving pain, improving function, and preventing carpal collapse through stable biomechanical integration.
- 11 March 2023
- Published by Elsevier in Hand Surgery and Rehabilitation
- Vol. 42 (3) , 208-213
Shape-modified radial forearm flap: does it still have a role in upper extremity reconstruction?
- 11 March 2023
- Published by Elsevier in Hand Surgery and Rehabilitation
- Vol. 42 (3) , 208-213
Shape-modified radial forearm flap: does it still have a role in upper extremity reconstruction?