Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Subrata Mondal has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Finite element analysis of vertebroplasty in the osteoporotic T11‐L1 vertebral body: Effects of bone cement formulation

    by Subrata Mondal, David B. MacManus, Federica Banche‐Niclot, Chiara Vitale‐Brovarone, Sonia Fiorilli, Helen O. McCarthy, Nicholas Dunne

    Vertebral compression fractures are one of the most severe clinical consequences of osteoporosis and the most common fragility fracture afflicting 570 and 1070 out of 100,000 men and women worldwide, respectively. Vertebroplasty (VP), a minimally invasive surgical procedure that involves the percutaneous injection of bone cement, is one of the most efficacious methods to stabilise osteoporotic vertebral compression fractures. However, postoperative fracture has been observed in up to 30% of patients following VP. Therefore, this study aims to investigate the effect of different injectable bone cement formulations on the stress distribution within the vertebrae and intervertebral discs due to VP and consequently recommend the optimal cement formulation. To achieve this, a 3D finite element (FE) model of the T11‐L1 vertebral body was developed from computed tomography scan data of the spine. Osteoporotic bone was modeled by reducing the Young's modulus by 20% in the cortical bone and 74% in cancellous bone. The FE model was subjected to different physiological movements, such as extension, flexion, bending, and compression. The osteoporotic model caused a reduction in the average von Mises stress compared with the normal model in the T12 cancellous bone and an increment in the average von Mises stress value at the T12 cortical bone. The effects of VP using different formulations of a novel injectable bone cement were modeled by replacing a region of T12 cancellous bone with the materials. Due to the injection of the bone cement at the T12 vertebra, the average von Mises stresses on cancellous bone increased and slightly decreased on the cortical bone under all loading conditions. The novel class of bone cements investigated herein demonstrated an effective restoration of stress distribution to physiological levels within treated vertebrae, which could offer a potential superior alternative for VP surgery as their anti‐osteoclastogenic properties could further enhance the appeal of their fracture treatment and may contribute to improved patient recovery and long‐term well‐being.


  • Open Access

    Effect of Uniaxial Compression Frequency on Osteogenic Cell Responses in Dynamic 3D Cultures

    by Georgia-Ioanna Kontogianni, Konstantinos Loukelis, Amedeo Franco Bonatti, Elisa Batoni, Carmelo De Maria, Raasti Naseem, Kenneth Dalgarno, Giovanni Vozzi, David B. MacManus, Subrata Mondal, et al.

    The application of mechanical stimulation on bone tissue engineering constructs aims to mimic the native dynamic nature of bone. Although many attempts have been made to evaluate the effect of applied mechanical stimuli on osteogenic differentiation, the conditions that govern this process have not yet been fully explored. In this study, pre-osteoblastic cells were seeded on PLLA/PCL/PHBV (90/5/5 wt.%) polymeric blend scaffolds. The constructs were subjected every day to cyclic uniaxial compression for 40 min at a displacement of 400 μm, using three frequency values, 0.5, 1, and 1.5 Hz, for up to 21 days, and their osteogenic response was compared to that of static cultures. Finite element simulation was performed to validate the scaffold design and the loading direction, and to assure that cells inside the scaffolds would be subjected to significant levels of strain during stimulation. None of the applied loading conditions negatively affected the cell viability. The alkaline phosphatase activity data indicated significantly higher values at all dynamic conditions compared to the static ones at day 7, with the highest response being observed at 0.5 Hz. Collagen and calcium production were significantly increased compared to static controls. These results indicate that all of the examined frequencies substantially promoted the osteogenic capacity.


  • Open Access

    A computational analysis of a novel therapeutic approach combining an advanced medicinal therapeutic device and a fracture fixation assembly for the treatment of osteoporotic fractures: Effects of physiological loading, interface conditions, and fracture fixation materials

    by Subrata Mondal, David B. MacManus, Amedeo Franco Bonatti, Carmelo De Maria, Kenny Dalgarno, Maria Chatzinikolaidou, Aurora De Acutis, Giovanni Vozzi, Sonia Fiorilli, Chiara Vitale-Brovarone, et al.

    The occurrence of periprosthetic femoral fractures (PFF) has increased in people with osteoporosis due to decreased bone density, poor bone quality, and stress shielding from prosthetic implants. PFF treatment in the elderly is a genuine concern for orthopaedic surgeons as no effective solution currently exists. Therefore, the goal of this study was to determine whether the design of a novel advanced medicinal therapeutic device (AMTD) manufactured from a polymeric blend in combination with a fracture fixation plate in the femur is capable of withstanding physiological loads without failure during the bone regenerative process. This was achieved by developing a finite element (FE) model of the AMTD together with a fracture fixation assembly, and a femur with an implanted femoral stem. The response of both normal and osteoporotic bone was investigated by implementing their respective material properties in the model. Physiological loading simulating the peak load during standing, walking, and stair climbing was investigated. The results showed that the fixation assembly was the prime load bearing component for this configuration of devices. Within the fixation assembly, the bone screws were found to have the highest stresses in the fixation assembly for all the loading conditions. Whereas the stresses within the AMTD were significantly below the maximum yield strength of the device's polymeric blend material. Furthermore, this study also investigated the performance of different fixation assembly materials and found Ti-6Al-4V to be the optimal material choice from those included in this study.


  • Open Access

    Study of “Discard Rate” of Whole Human Blood: Useful Blood Center Quality Indicator

    by Gopeswar Mukherjee, Sandipan Ghosh, Sumitra Halder, Subrata Mondal

    Background: Blood is a valuable, life-saving material which should not be discarded or wasted to have the required blood supply to the patients. Aims and Objectives: The aim of the present study is to find out the major causes of blood discard from the blood center so that preventive strategies can be undertaken by proper training of blood center personnel, awareness of blood donor motivators. Materials and Methods: In this study, the number of discarded blood units and the total number of units collected have been taken from blood center registers for each year and then the discard rate has been calculated. Results: Discard rate has been found more in this study due to transfusion transmissible infections positive cases in comparison to discard due to insufficient quantity. No discard due to other causes recorded in the Blood Centre Registers. Conclusion: From this study, it is concluded that proper screening of blood donors by proper medical examination and donor counseling are very important in this connection. Moreover, proper training of the blood center personnel and blood donor motivators are equally important.