Swagat Pati
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Swagat Pati has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Abhijeet Choudhury
Department of Electrical and Electronics Engineering, ITER, Siksha O Anusandhan Deemed to be University, Bhubaneswar, India
8 shared publications - Sanjeeb Kumar Kar
Siksha ‘O’ Anusandhan (Deemed to be University)
8 shared publications - Renu Sharma
Department of Electrical Engineering, ITER, SOA Deemed to be University, Bhubaneswar, India
6 shared publications - Soumya Mohanty
Department of Electrical Engineering, ITER, Siksha O Anusandhan Deemed to be University, Bhubaneswar, India
5 shared publications Binod Kumar Sahu
Department of Electrical Engineering, ITER, Siksha O Anusandhan Deemed to be University, Bhubaneswar, India
3 shared publicationsFuta Osumanu
Department of Electrical/Electronic Engineering, Accra Technical University, Accra, Ghana
3 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by KEAI Publishing in Unconventional Resources
- Vol. 9
A review on microgrid control: Conventional, advanced and intelligent control approaches
- 1 January 2026
- Published by KEAI Publishing in Unconventional Resources
- Vol. 9
Open AccessA review on microgrid control: Conventional, advanced and intelligent control approaches
- Open Access
- 25 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 169098-169113
A Back-to-Back Converter-Based Electric Spring With an Improved Control Structure for Unbalanced Load Operations
This article proposes a back-to-back converter-based electric spring for the voltage and frequency regulation in a self-excited induction generator-based isolated generation system. The proposed electric spring topology gives the system seamless performance with linear, non-linear, and unbalanced load conditions. The electric spring in this work is equipped with a modified complex coefficient filter, which eliminates the harmonics and the unbalanced negative sequence component from the system currents caused by unbalanced loads. The performance of the proposed electric spring was evaluated with non-linear loads, unbalanced critical load, and unbalanced non-critical load. The proposed electric spring works effectively to regulate the system voltage and frequency within 2% tolerance limits. In the presence of non-linear loads, the THD of the generator current could be reduced to 1.97%, proving the electric spring’s efficacy as an active filter. The modified complex coefficient filter-based shunt side control strategy effectively eliminates the unbalanced current components from the system currents, which keeps the self-excited induction generator unaffected by load imbalances caused by both the critical load and non-critical load sides. The shunt side control strategy also effectively maintained the DC link voltage fluctuation within 16V, which is 6.4% of the rated value of 250V. The proposed minimum voltage injection control strategy to control the series converter was highly effective in maintaining a constant voltage of 230V during unbalanced non-critical load conditions. The real-time validation of the proposed work is done with OPAL-RT 4510 and 4520 platforms, and the detailed results and their analysis are presented in this work.
- 25 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 169098-169113
Open AccessA Back-to-Back Converter-Based Electric Spring With an Improved Control Structure for Unbalanced Load Operations
This article proposes a back-to-back converter-based electric spring for the voltage and frequency regulation in a self-excited induction generator-based isolated generation system. The proposed electric spring topology gives the system seamless performance with linear, non-linear, and unbalanced load conditions. The electric spring in this work is equipped with a modified complex coefficient filter, which eliminates the harmonics and the unbalanced negative sequence component from the system currents caused by unbalanced loads. The performance of the proposed electric spring was evaluated with non-linear loads, unbalanced critical load, and unbalanced non-critical load. The proposed electric spring works effectively to regulate the system voltage and frequency within 2% tolerance limits. In the presence of non-linear loads, the THD of the generator current could be reduced to 1.97%, proving the electric spring’s efficacy as an active filter. The modified complex coefficient filter-based shunt side control strategy effectively eliminates the unbalanced current components from the system currents, which keeps the self-excited induction generator unaffected by load imbalances caused by both the critical load and non-critical load sides. The shunt side control strategy also effectively maintained the DC link voltage fluctuation within 16V, which is 6.4% of the rated value of 250V. The proposed minimum voltage injection control strategy to control the series converter was highly effective in maintaining a constant voltage of 230V during unbalanced non-critical load conditions. The real-time validation of the proposed work is done with OPAL-RT 4510 and 4520 platforms, and the detailed results and their analysis are presented in this work.
- Open Access
- 17 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 165290-165302
An Improved Current Control Scheme for Reduced Switching Frequency in a Rooftop Grid-Interfaced PV System
This paper presents a novel modified unipolar-toggle hysteresis current control (UTHCC) strategy for a single-phase grid-connected photovoltaic (GCPV) rooftop system. The proposed UTHCC is designed to minimise the switching frequency and hence the switching losses in the GCPV rooftop system, thus improving its efficiency, without compromising the THD. In this work, the performance of the proposed scheme is compared with conventional HCC and unipolar-toggle (UT) modulation schemes. The comparison study is done through simulation and using a real-time platform, along with experimental validation of the same. The proposed UTHCC scheme was found to be capable of reducing the switching frequency by nearly 46% (theoretically) and by up to 32% through real-time and experimental validation, along with a reduction in switching losses, which is about 35% of that with conventional HCC. The proposed UTHCC scheme was also found to have 3.4% lower THD as compared to the UT modulation scheme. The proposed work is modelled in the MATLAB/Simulink platform and validated using the OPAL-RT 4510 real-time platform as well as an experimental setup.
- 17 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 165290-165302
Open AccessAn Improved Current Control Scheme for Reduced Switching Frequency in a Rooftop Grid-Interfaced PV System
This paper presents a novel modified unipolar-toggle hysteresis current control (UTHCC) strategy for a single-phase grid-connected photovoltaic (GCPV) rooftop system. The proposed UTHCC is designed to minimise the switching frequency and hence the switching losses in the GCPV rooftop system, thus improving its efficiency, without compromising the THD. In this work, the performance of the proposed scheme is compared with conventional HCC and unipolar-toggle (UT) modulation schemes. The comparison study is done through simulation and using a real-time platform, along with experimental validation of the same. The proposed UTHCC scheme was found to be capable of reducing the switching frequency by nearly 46% (theoretically) and by up to 32% through real-time and experimental validation, along with a reduction in switching losses, which is about 35% of that with conventional HCC. The proposed UTHCC scheme was also found to have 3.4% lower THD as compared to the UT modulation scheme. The proposed work is modelled in the MATLAB/Simulink platform and validated using the OPAL-RT 4510 real-time platform as well as an experimental setup.
- Open Access
- 6 April 2025
- Published by Elsevier in Green Energy and Intelligent Transportation
- Vol. 5 (2)
Power management using an improved EMS algorithm in a stand-alone hybrid PV-PEMFC microgrid with reduced converter count
- 6 April 2025
- Published by Elsevier in Green Energy and Intelligent Transportation
- Vol. 5 (2)
Open AccessPower management using an improved EMS algorithm in a stand-alone hybrid PV-PEMFC microgrid with reduced converter count
- Open Access
- 3 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 41471-41485
A Reduced DC-Link Voltage-Based NSC Topology for an On-Grid PEMFC Microgrid Capable of Handling Unbalanced Load Conditions and Grid Disturbances
This article presents a nine-switch converter-based on-grid proton exchange membrane fuel cell microgrid system and its control with a reduced DC-link voltage requirement for the NSC. With the proposed topology, the do link voltage requirement of the NSC could be reduced by nearly 33%. Apart from the DC link voltage reduction, this work proposes a minimum voltage injection-based control scheme, which helps achieve the claimed voltage reduction. This work has also proposed a self-tuned filter-based modified indirect current control scheme, which ensures a balanced grid current during unbalanced load conditions. The proposed system is evaluated under various grid and load-side disturbances. The performance of the proposed system, along with its associated control structures, is studied under nearly 28% grid voltage sag and 10% swell. The control structure delivers a constant load voltage and a steady grid power flow during grid voltage sag and swell. The proposed system also performed efficiently during load and generation side disturbances Such as load change, change in active power, and reactive power references. During unbalanced load conditions, the proposed modified indirect current control scheme effectively compensated for the load imbalance and resulted in balanced grid currents. The whole system is mathematically modeled in the Matlab/Simulink platform, and the system’s performance is validated using an OPAL-RT 4510 real-time platform.
- 3 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 41471-41485
Open AccessA Reduced DC-Link Voltage-Based NSC Topology for an On-Grid PEMFC Microgrid Capable of Handling Unbalanced Load Conditions and Grid Disturbances
This article presents a nine-switch converter-based on-grid proton exchange membrane fuel cell microgrid system and its control with a reduced DC-link voltage requirement for the NSC. With the proposed topology, the do link voltage requirement of the NSC could be reduced by nearly 33%. Apart from the DC link voltage reduction, this work proposes a minimum voltage injection-based control scheme, which helps achieve the claimed voltage reduction. This work has also proposed a self-tuned filter-based modified indirect current control scheme, which ensures a balanced grid current during unbalanced load conditions. The proposed system is evaluated under various grid and load-side disturbances. The performance of the proposed system, along with its associated control structures, is studied under nearly 28% grid voltage sag and 10% swell. The control structure delivers a constant load voltage and a steady grid power flow during grid voltage sag and swell. The proposed system also performed efficiently during load and generation side disturbances Such as load change, change in active power, and reactive power references. During unbalanced load conditions, the proposed modified indirect current control scheme effectively compensated for the load imbalance and resulted in balanced grid currents. The whole system is mathematically modeled in the Matlab/Simulink platform, and the system’s performance is validated using an OPAL-RT 4510 real-time platform.
- Open Access
- 1 January 2025
- Published by KEAI Publishing in Unconventional Resources
- Vol. 5
Performance analysis of PID and SMC for PEMFC-based grid integrated system using nine switch converter - A comparative study
- 1 January 2025
- Published by KEAI Publishing in Unconventional Resources
- Vol. 5
Open AccessPerformance analysis of PID and SMC for PEMFC-based grid integrated system using nine switch converter - A comparative study
- 5 December 2024
- Published by Elsevier in Computers and Electrical Engineering
- Vol. 122
Minimum grid involvement-based control of a grid-connected PV-battery system using nine switch converter
- 5 December 2024
- Published by Elsevier in Computers and Electrical Engineering
- Vol. 122
Minimum grid involvement-based control of a grid-connected PV-battery system using nine switch converter
- Open Access
- 26 February 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-21
Optimizing grid-connected PV systems with novel super-twisting sliding mode controllers for real-time power management
Over the past years, the use of renewable energy sources (RESs) has grown significantly as a means of providing clean energy to counteract the devastating effects of climate change. Reducing energy costs and pollution have been the primary causes of the rise in solar photovoltaic (PV) system integrations with the grid in recent years. A load that is locally connected to a GCPV requires both active and reactive power control. In order to control both active and reactive power, MAs and advanced controllers are essential. Researchers have used one of the recently developed MAs, known as the CAOA, which is based on mathematical arithmetic operators to tackle a few real-world optimization problems. Some disadvantages of CAOA include its natural tendency to converge to a local optimum and its limited capacity for exploration. By merging the PSO and CAOA methodologies, this article suggests the IAOA. To show how applicable IAOA is, its performance has been evaluated using four benchmark functions. The implementation of an IAOA-based ST-SMC for active and reactive power control is addressed in this article, which offers an innovative approach of research. In comparison to PSO-based ST-SMC and CAOA-based ST-SMC, the proposed IAOA-based ST-SMC appears to be superior, with settling time for active and reactive power control at a minimum of 0.01012 s and 0.5075 s. A real-time OPAL-RT 4510 simulator is used to validate the performance results of a 40 kW GCPV system after it has been investigated in the MATLAB environment.
- 26 February 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-21
Open AccessOptimizing grid-connected PV systems with novel super-twisting sliding mode controllers for real-time power management
Over the past years, the use of renewable energy sources (RESs) has grown significantly as a means of providing clean energy to counteract the devastating effects of climate change. Reducing energy costs and pollution have been the primary causes of the rise in solar photovoltaic (PV) system integrations with the grid in recent years. A load that is locally connected to a GCPV requires both active and reactive power control. In order to control both active and reactive power, MAs and advanced controllers are essential. Researchers have used one of the recently developed MAs, known as the CAOA, which is based on mathematical arithmetic operators to tackle a few real-world optimization problems. Some disadvantages of CAOA include its natural tendency to converge to a local optimum and its limited capacity for exploration. By merging the PSO and CAOA methodologies, this article suggests the IAOA. To show how applicable IAOA is, its performance has been evaluated using four benchmark functions. The implementation of an IAOA-based ST-SMC for active and reactive power control is addressed in this article, which offers an innovative approach of research. In comparison to PSO-based ST-SMC and CAOA-based ST-SMC, the proposed IAOA-based ST-SMC appears to be superior, with settling time for active and reactive power control at a minimum of 0.01012 s and 0.5075 s. A real-time OPAL-RT 4510 simulator is used to validate the performance results of a 40 kW GCPV system after it has been investigated in the MATLAB environment.
- Open Access
- 18 January 2024
- Published by Elsevier in e-Prime - Advances in Electrical Engineering, Electronics and Energy
- Vol. 7
Integration of a proton exchange membrane fuel cell system for voltage and frequency stabilization in a micro hydro system
- 18 January 2024
- Published by Elsevier in e-Prime - Advances in Electrical Engineering, Electronics and Energy
- Vol. 7
Open AccessIntegration of a proton exchange membrane fuel cell system for voltage and frequency stabilization in a micro hydro system
- Open Access
- 18 September 2023
- Published by Institution of Engineering and Technology (IET) in IET Energy Systems Integration
- Vol. 5 (4) , 491-511
A novel optimally tuned super twisting sliding mode controller for active and reactive power control in grid‐interfaced photovoltaic system
In photovoltaic (PV) systems, inverters play a crucial role for supplying electricity to meet the demand while maintaining power quality. For a local load connected to a grid‐interfaced photovoltaic (GIPV) system, active and reactive power control is necessary at the distribution level. Thus, the foremost purpose of this article is to get the best optimally designed robust controller for control of active and reactive power. A GIPV system with Improved Arithmetic Optimisation Algorithm (IAOA)‐based Super Twisting Sliding Mode Controller (ST‐SMC) methodology has been proposed in this article for active and reactive power management. The conventional PI controller in the GIPV system that is most frequently used has considerable undershoot and a long settling period. PI controller tuning parameters were also changed to account for the wide change in the reference pattern. Therefore, STSMC and SMC are used for ensuring robustness against external disturbances. The conventional SMC comes out to have a chattering issue. Furthermore, the proposed IAOA technique is validated through some benchmark functions. The proposed IAOA technique outperforms Particle Swarm Optimisation (PSO), Forensic Based Investigation (FBI), and Traditional Arithmetic Optimisation Algorithm (TAOA) in terms of the number of iterations and accurately achieving optimal solutions for active and reactive power control. The results show that the proposed IAOA‐based STSMC technique has an improved performance of settling time and undershoot for active and reactive power control. This article also presents stability analysis and robustness test of the above mentioned controllers to illustrate the effectiveness of each optimally designed controller. A 40 kW GIPV system performance is evaluated using the MATLAB environment, and the results are validated in a real‐time simulator platform OPAL‐RT 4510.
- 18 September 2023
- Published by Institution of Engineering and Technology (IET) in IET Energy Systems Integration
- Vol. 5 (4) , 491-511
Open AccessA novel optimally tuned super twisting sliding mode controller for active and reactive power control in grid‐interfaced photovoltaic system
In photovoltaic (PV) systems, inverters play a crucial role for supplying electricity to meet the demand while maintaining power quality. For a local load connected to a grid‐interfaced photovoltaic (GIPV) system, active and reactive power control is necessary at the distribution level. Thus, the foremost purpose of this article is to get the best optimally designed robust controller for control of active and reactive power. A GIPV system with Improved Arithmetic Optimisation Algorithm (IAOA)‐based Super Twisting Sliding Mode Controller (ST‐SMC) methodology has been proposed in this article for active and reactive power management. The conventional PI controller in the GIPV system that is most frequently used has considerable undershoot and a long settling period. PI controller tuning parameters were also changed to account for the wide change in the reference pattern. Therefore, STSMC and SMC are used for ensuring robustness against external disturbances. The conventional SMC comes out to have a chattering issue. Furthermore, the proposed IAOA technique is validated through some benchmark functions. The proposed IAOA technique outperforms Particle Swarm Optimisation (PSO), Forensic Based Investigation (FBI), and Traditional Arithmetic Optimisation Algorithm (TAOA) in terms of the number of iterations and accurately achieving optimal solutions for active and reactive power control. The results show that the proposed IAOA‐based STSMC technique has an improved performance of settling time and undershoot for active and reactive power control. This article also presents stability analysis and robustness test of the above mentioned controllers to illustrate the effectiveness of each optimally designed controller. A 40 kW GIPV system performance is evaluated using the MATLAB environment, and the results are validated in a real‐time simulator platform OPAL‐RT 4510.