Yuhao Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yuhao Huang has a total of 131 co-authors. Here are the top co-authors by number of shared publications:
- Dong Ni
Shenzhen University
9 shared publications - Haoran Dou
Centre for Computational Imaging and Modelling in Medicine (CIMIM), The Christabel Pankhurst Institute, The University of Manchester, Manchester, UK
5 shared publications Xin Yang
Medical Ultrasound Image Computing (MUSIC) Lab, School of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen, China
5 shared publicationsYuanji Zhang
Shenzhen Luohu People's Hospital (The Third Affiliated Hospital of Shenzhen University), Shenzhen, China
5 shared publicationsLian Liu
Medical Ultrasound Image Computing (MUSIC) Lab, School of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen, China
3 shared publications- Xin Yang
Shenzhen University
3 shared publications
Latest Publications
- 2 July 2026
- Published by Elsevier in Medical Image Analysis
- Vol. 113, 104201
FAA-Net: Fetal abdominal anomaly diagnosis in prenatal ultrasound via LLM-enhanced multi-instance learning
- 2 July 2026
- Published by Elsevier in Medical Image Analysis
- Vol. 113, 104201
FAA-Net: Fetal abdominal anomaly diagnosis in prenatal ultrasound via LLM-enhanced multi-instance learning
- 17 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. PP (21682194) , 1-16
OnUVS: An Online Motion Transfer Framework with Content-Texture Decoupling for High-Fidelity Ultrasound Video Synthesis
Ultrasound (US) imaging plays a crucial role in diagnosing heart and pelvic diseases, where sonographers tend to evaluate dynamic motion and structure. However, the scarcity of US videos for rare cases limits training opportunities for novice sonographers and deep learning models, hindering detection rates and clinical di agnostic applications. US video synthesis is a promising solution to this issue. Nevertheless, accurately imitating the intricate motion of the anatomy while preserving image f idelity presents a significant challenge. In this work, we propose OnUVS, a novel online feature-decoupling frame work for high-fidelity US video synthesis. First, to simulate realistic motion, we incorporate keypoints into anatomical learning through a weakly supervised training approach, which enhances motion representation and minimizes the need for fully annotated data. Second, we implement a dual decoder generator that effectively balances content and textural features of generated frames, significantly enhancing the image fidelity of US videos. Third, a multi-scale discriminator further refines the sharpness and fine details, ensuring high-fidelity video synthesis. Fourth, an online learning strategy is designed to smooth coherence between frames by constraining the keypoint trajectories during inference. Validation on echocardiographic and pelvic floor US datasets demonstrates that OnUVS outperforms existing methods, achieving a 22.08% improvement in motion consistency (FVD) and 25.04% in image fidelity (FID). To facilitate reproducibility, we publicly release the code of OnUVSat: https://github.com/LucyChen159/OnUVS.
- 17 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. PP (21682194) , 1-16
OnUVS: An Online Motion Transfer Framework with Content-Texture Decoupling for High-Fidelity Ultrasound Video Synthesis
Ultrasound (US) imaging plays a crucial role in diagnosing heart and pelvic diseases, where sonographers tend to evaluate dynamic motion and structure. However, the scarcity of US videos for rare cases limits training opportunities for novice sonographers and deep learning models, hindering detection rates and clinical di agnostic applications. US video synthesis is a promising solution to this issue. Nevertheless, accurately imitating the intricate motion of the anatomy while preserving image f idelity presents a significant challenge. In this work, we propose OnUVS, a novel online feature-decoupling frame work for high-fidelity US video synthesis. First, to simulate realistic motion, we incorporate keypoints into anatomical learning through a weakly supervised training approach, which enhances motion representation and minimizes the need for fully annotated data. Second, we implement a dual decoder generator that effectively balances content and textural features of generated frames, significantly enhancing the image fidelity of US videos. Third, a multi-scale discriminator further refines the sharpness and fine details, ensuring high-fidelity video synthesis. Fourth, an online learning strategy is designed to smooth coherence between frames by constraining the keypoint trajectories during inference. Validation on echocardiographic and pelvic floor US datasets demonstrates that OnUVS outperforms existing methods, achieving a 22.08% improvement in motion consistency (FVD) and 25.04% in image fidelity (FID). To facilitate reproducibility, we publicly release the code of OnUVSat: https://github.com/LucyChen159/OnUVS.
- Open Access
- 10 October 2025
- Published by Elsevier in eClinicalMedicine
- Vol. 89, 103552
Deep learning algorithms for identifying developmental dysplasia of the hip based on sonographic images: a retrospective, prospective, multicenter study in China
- 10 October 2025
- Published by Elsevier in eClinicalMedicine
- Vol. 89, 103552
Open AccessDeep learning algorithms for identifying developmental dysplasia of the hip based on sonographic images: a retrospective, prospective, multicenter study in China
- 17 July 2025
- Published by Elsevier in Medical Image Analysis
- Vol. 105, 103725
FetalFlex: Anatomy-guided diffusion model for flexible control on fetal ultrasound image synthesis
- 17 July 2025
- Published by Elsevier in Medical Image Analysis
- Vol. 105, 103725
FetalFlex: Anatomy-guided diffusion model for flexible control on fetal ultrasound image synthesis
- 22 March 2025
- Published by Elsevier in Medical Image Analysis
- Vol. 102, 103552
Flip Learning: Weakly supervised erase to segment nodules in breast ultrasound
- 22 March 2025
- Published by Elsevier in Medical Image Analysis
- Vol. 102, 103552
Flip Learning: Weakly supervised erase to segment nodules in breast ultrasound
- 3 February 2025
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 261, 108619
Standard plane localization using denoising diffusion model with multi-scale guidance
- 3 February 2025
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 261, 108619
Standard plane localization using denoising diffusion model with multi-scale guidance
- 18 November 2024
- Published by Springer Nature in Nature Methods
- Vol. 22 (1) , 18-19
A foundation model unlocks unified biomedical image analysis
- 18 November 2024
- Published by Springer Nature in Nature Methods
- Vol. 22 (1) , 18-19
A foundation model unlocks unified biomedical image analysis
- Top Cited Papers
- 7 December 2023
- Published by Elsevier in Medical Image Analysis
- Vol. 92, 103061
Segment anything model for medical images?
- 7 December 2023
- Published by Elsevier in Medical Image Analysis
- Vol. 92, 103061
Top Cited PapersSegment anything model for medical images?
- 21 October 2023
- Published by Elsevier in Medical Image Analysis
- Vol. 91, 103013
FetusMapV2: Enhanced fetal pose estimation in 3D ultrasound
- 21 October 2023
- Published by Elsevier in Medical Image Analysis
- Vol. 91, 103013
FetusMapV2: Enhanced fetal pose estimation in 3D ultrasound
- Open Access
Automatic Emergency Dust-Free solution on-board International Space Station with Bi-GRU (AED-ISS)
With a rising attention for the issue of PM2.5 or PM0.3, particulate matters have become not only a potential threat to both the environment and human, but also a harming existence to instruments onboard International Space Station (ISS). Our team is aiming to relate various concentration of particulate matters to magnetic fields, humidity, acceleration, temperature, pressure and CO2 concentration. Our goal is to establish an early warning system (EWS), which is able to forecast the levels of particulate matters and provides ample reaction time for astronauts to protect their instruments in some experiments or increase the accuracy of the measurements; In addition, the constructed model can be further developed into a prototype of a remote-sensing smoke alarm for applications related to fires. In this article, we will implement the Bi-GRU (Bidirectional Gated Recurrent Unit) algorithms that collect data for past 90 minutes and predict the levels of particulates which over 2.5 micrometer per 0.1 liter for the next 1 minute, which is classified as an early warning
Open AccessAutomatic Emergency Dust-Free solution on-board International Space Station with Bi-GRU (AED-ISS)
With a rising attention for the issue of PM2.5 or PM0.3, particulate matters have become not only a potential threat to both the environment and human, but also a harming existence to instruments onboard International Space Station (ISS). Our team is aiming to relate various concentration of particulate matters to magnetic fields, humidity, acceleration, temperature, pressure and CO2 concentration. Our goal is to establish an early warning system (EWS), which is able to forecast the levels of particulate matters and provides ample reaction time for astronauts to protect their instruments in some experiments or increase the accuracy of the measurements; In addition, the constructed model can be further developed into a prototype of a remote-sensing smoke alarm for applications related to fires. In this article, we will implement the Bi-GRU (Bidirectional Gated Recurrent Unit) algorithms that collect data for past 90 minutes and predict the levels of particulates which over 2.5 micrometer per 0.1 liter for the next 1 minute, which is classified as an early warning