Abed Mohamed Affoune
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Abed Mohamed Affoune has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Mohamed Lyamine Chelaghmia
Laboratory of Industrial Analysis and Material Engineering, Department of Process Engineering, University 8 May 1945 Guelma, Guelma, Algeria
7 shared publications - Mouna Nacef
Laboratory of Industrial Analysis and Material Engineering, Department of Process Engineering, University 8 May 1945 Guelma, BP 401, Guelma 24000, Algeria
6 shared publications Imene Atek
Laboratory of Process Engineering for Sustainable Development and Health Products, Preparatory Classes Department, National Polytechnic School of Constantine, Constantine 25000, Algeria
4 shared publicationsRafiaa Kihal
Laboratoire d'Analyses Industrielles et Génie des Matériaux Université 8 Mai 1945 Guelma 24000 BP 401 Guelma Algeria
4 shared publicationsAkifumi Yamada
Department of Chemistry, Faculty of Engineering, Nagaoka University of Technology, Kamitomioka 1603-1, Nagaoka, Niigata 940-2188, Japan
3 shared publicationsHassiba Rahal
3 shared publications
Latest Publications
- Open Access
- 16 December 2025
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 15 (59) , 50571-50581
Computational and experimental determination of electrochemical standard rate constant from cyclic voltammetry: insights into α + β ≠ 1 systems
A combined computational-experimental approach determines k 0 from cyclic voltammetry ( α + β ≠ 1), validated with the ferro/ferricyanide couple.
- 16 December 2025
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 15 (59) , 50571-50581
Open AccessComputational and experimental determination of electrochemical standard rate constant from cyclic voltammetry: insights into α + β ≠ 1 systems
A combined computational-experimental approach determines k 0 from cyclic voltammetry ( α + β ≠ 1), validated with the ferro/ferricyanide couple.
- Open Access
- 8 October 2025
- Published by Royal Society of Chemistry (RSC) in Chemical Science
- Vol. 16 (45) , 21562-21572
Exploring the determination of the standard rate constant in electrochemical metal deposition: theory and experiment
Interpolation equations from kinetic curves enable k 0 extraction from Δ E p in electrodeposition, accounting for α + β effects and experimental validation.
- 8 October 2025
- Published by Royal Society of Chemistry (RSC) in Chemical Science
- Vol. 16 (45) , 21562-21572
Open AccessExploring the determination of the standard rate constant in electrochemical metal deposition: theory and experiment
Interpolation equations from kinetic curves enable k 0 extraction from Δ E p in electrodeposition, accounting for α + β effects and experimental validation.
- 3 May 2022
- Published by Wiley in Electroanalysis
- Vol. 34 (11) , 1735-1744
In situ Growth of Ni(OH)2 Nanoparticles on 316L Stainless Steel Foam: An Efficient Three‐dimensional Non‐enzymatic Glucose Electrochemical Sensor in Real Human Blood Serum Samples
For the first time, nickel hydroxide nanoparticles (Ni(OH)2 NPs) grown on 316L stainless steel foam were used as a non‐enzymatic electrochemical glucose sensor. The Ni(OH)2/SSF‐316L was elaborated by applying a simple ultrafast CV method without nickel salts addition. Ni(OH)2/SSF‐316L was characterized by SEM and XRD. The electrochemical behavior was investigated by CV, EIS, and amperometric measurements. The fabricated sensor revealed higher sensitivity 1062 μA mM−1cm−2, wide linear range from 1.0 μM to 4.0 mM with a low detection limit of 2.0 μM and good selectivity. In addition, real sample analysis was performed for controlled glucose in real blood serum.
- 3 May 2022
- Published by Wiley in Electroanalysis
- Vol. 34 (11) , 1735-1744
In situ Growth of Ni(OH)2 Nanoparticles on 316L Stainless Steel Foam: An Efficient Three‐dimensional Non‐enzymatic Glucose Electrochemical Sensor in Real Human Blood Serum Samples
For the first time, nickel hydroxide nanoparticles (Ni(OH)2 NPs) grown on 316L stainless steel foam were used as a non‐enzymatic electrochemical glucose sensor. The Ni(OH)2/SSF‐316L was elaborated by applying a simple ultrafast CV method without nickel salts addition. Ni(OH)2/SSF‐316L was characterized by SEM and XRD. The electrochemical behavior was investigated by CV, EIS, and amperometric measurements. The fabricated sensor revealed higher sensitivity 1062 μA mM−1cm−2, wide linear range from 1.0 μM to 4.0 mM with a low detection limit of 2.0 μM and good selectivity. In addition, real sample analysis was performed for controlled glucose in real blood serum.
- Open Access
- 1 January 2019
- Published by National Library of Serbia in Journal of the Serbian Chemical Society
- Vol. 84 (1) , 41-53
Effects of thiourea on the kinetics and electrochemical nucleation of tin electrodeposition from stannous chloride bath in acidic medium
The effects of thiourea (TU) on the kinetics and electrochemical nucleation of tin from stannous chloride bath in acidic medium have been investigated by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and chronoamperometry. CV results showed that the tin reduction is a one-step reaction and indicated that TU inhibited the reduction of tin ions at high concentration. EIS analysis showed that the electrodeposition process of tin is affected by the addition of TU. The nucleation mechanism of tin was studied using both Sharifker?Hills (SH) and Palomar?Pardav? (PP) models. SH model indicated that hydrogen evolution and tin reduction occurred simultaneously. Non-dimensional current-time transients curves based on PP model revealed that the tin nucleation followed 3D progressive mechanism without TU and with 0.01 M TU, while the nucleation process changes to 3D instantaneous in presence of 0.1 M TU. However, at 1 M TU, the nucleation mechanism is located between instantaneous and progressive model. The proton reduction reaction was inhibited at all concentrations of TU. Quantitative determination showed that in the presence of TU, the diffusion coefficient of tin species, the hydrogen evolution rate constant, the nucleation rate constant and the number of active sites were decreased.
- 1 January 2019
- Published by National Library of Serbia in Journal of the Serbian Chemical Society
- Vol. 84 (1) , 41-53
Open AccessEffects of thiourea on the kinetics and electrochemical nucleation of tin electrodeposition from stannous chloride bath in acidic medium
The effects of thiourea (TU) on the kinetics and electrochemical nucleation of tin from stannous chloride bath in acidic medium have been investigated by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and chronoamperometry. CV results showed that the tin reduction is a one-step reaction and indicated that TU inhibited the reduction of tin ions at high concentration. EIS analysis showed that the electrodeposition process of tin is affected by the addition of TU. The nucleation mechanism of tin was studied using both Sharifker?Hills (SH) and Palomar?Pardav? (PP) models. SH model indicated that hydrogen evolution and tin reduction occurred simultaneously. Non-dimensional current-time transients curves based on PP model revealed that the tin nucleation followed 3D progressive mechanism without TU and with 0.01 M TU, while the nucleation process changes to 3D instantaneous in presence of 0.1 M TU. However, at 1 M TU, the nucleation mechanism is located between instantaneous and progressive model. The proton reduction reaction was inhibited at all concentrations of TU. Quantitative determination showed that in the presence of TU, the diffusion coefficient of tin species, the hydrogen evolution rate constant, the nucleation rate constant and the number of active sites were decreased.
- 27 November 2018
- Published by Wiley in Electroanalysis
- Vol. 31 (1) , 113-120
Electrochemical Investigation of Glucose on a Highly Sensitive Nickel‐Copper Modified Pencil Graphite Electrode
Novel nickel‐copper modified pencil graphite electrode (Ni−Cu/PGE) was fabricated and used as non‐enzymatic sensor for glucose determination. Ni and copper were electrodeposited on PGE using cyclic voltammetry. Morphology and composition of the modified PGE electrode were characterized by field‐emission gun scanning electron microscopy (FEG‐SEM), energy‐dispersive X‐ray spectroscopy (EDX) and Fourier transform infrared spectroscopy (FT‐IR). Electrochemical oxidation of glucose was evaluated by cyclic voltammetry as well as by amperometry. Electrochemical measurements indicate that the Ni−Cu/PGE exhibits a high sensitivity of 2951 μA mM−1 cm−2, and a low detection limit of 0.99 μM which are, respectively, three times higher and twice lower than that on Ni/PGE prepared in the same conditions. Moreover, Ni−Cu/PGE exhibits a wider linear range from 1 to 10000 μM with a rapid response time within 2 s. Moreover, Ni−Cu/PGE showed a remarkable stability. The electrode was successfully applied for determination of glucose concentration in human blood without significant interference from potential endogenic interferents. The good applicability of the elaborated sensor made Ni−Cu/PGE promising for the development of effective and inexpensive non‐enzymatic glucose sensor.
- 27 November 2018
- Published by Wiley in Electroanalysis
- Vol. 31 (1) , 113-120
Electrochemical Investigation of Glucose on a Highly Sensitive Nickel‐Copper Modified Pencil Graphite Electrode
Novel nickel‐copper modified pencil graphite electrode (Ni−Cu/PGE) was fabricated and used as non‐enzymatic sensor for glucose determination. Ni and copper were electrodeposited on PGE using cyclic voltammetry. Morphology and composition of the modified PGE electrode were characterized by field‐emission gun scanning electron microscopy (FEG‐SEM), energy‐dispersive X‐ray spectroscopy (EDX) and Fourier transform infrared spectroscopy (FT‐IR). Electrochemical oxidation of glucose was evaluated by cyclic voltammetry as well as by amperometry. Electrochemical measurements indicate that the Ni−Cu/PGE exhibits a high sensitivity of 2951 μA mM−1 cm−2, and a low detection limit of 0.99 μM which are, respectively, three times higher and twice lower than that on Ni/PGE prepared in the same conditions. Moreover, Ni−Cu/PGE exhibits a wider linear range from 1 to 10000 μM with a rapid response time within 2 s. Moreover, Ni−Cu/PGE showed a remarkable stability. The electrode was successfully applied for determination of glucose concentration in human blood without significant interference from potential endogenic interferents. The good applicability of the elaborated sensor made Ni−Cu/PGE promising for the development of effective and inexpensive non‐enzymatic glucose sensor.
- 1 June 2018
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 818, 35-43
Semi-analytical modelling of linear scan voltammetric responses for soluble-insoluble system: The case of metal deposition
- 1 June 2018
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 818, 35-43
Semi-analytical modelling of linear scan voltammetric responses for soluble-insoluble system: The case of metal deposition
- 27 February 2018
- Published by Wiley in Electroanalysis
- Vol. 30 (6) , 1117-1124
Facile Synthesis of Ni(OH)2 Modified Disposable Pencil Graphite Electrode and its Application for Highly Sensitive Non‐enzymatic Glucose Sensor
In this study, a low‐cost, disposable, sensitive and selective electrochemical sensor was developed for glucose determination, which is based on a pencil graphite electrode (PGE) modified with nickel hydroxide. Cyclic voltammetry was used to deposit nickel on PGE. The morphology and composition of the unmodified and modified PGE electrodes were characterized by field‐emission scanning electron microscopy (FE‐SEM), atomic force microscopy (AFM) and energy‐dispersive X‐ray spectroscopy (EDX). The performance of the as modified electrode towards the electrooxidation of glucose in alkaline media was evaluated with cyclic voltammetry and amperometry techniques. A linear relationship between the concentration of glucose and oxidation peak currents was observed in two concentration ranges of 0.004–3.5 mM and 3.5–9.0 mM. The detection limit was 2 μM at signal‐to‐noise ratio of 3. In addition to a fast response time (2/PGE sensor was successfully tested in the determination of glucose in human blood serum for the first time in the literature.
- 27 February 2018
- Published by Wiley in Electroanalysis
- Vol. 30 (6) , 1117-1124
Facile Synthesis of Ni(OH)2 Modified Disposable Pencil Graphite Electrode and its Application for Highly Sensitive Non‐enzymatic Glucose Sensor
In this study, a low‐cost, disposable, sensitive and selective electrochemical sensor was developed for glucose determination, which is based on a pencil graphite electrode (PGE) modified with nickel hydroxide. Cyclic voltammetry was used to deposit nickel on PGE. The morphology and composition of the unmodified and modified PGE electrodes were characterized by field‐emission scanning electron microscopy (FE‐SEM), atomic force microscopy (AFM) and energy‐dispersive X‐ray spectroscopy (EDX). The performance of the as modified electrode towards the electrooxidation of glucose in alkaline media was evaluated with cyclic voltammetry and amperometry techniques. A linear relationship between the concentration of glucose and oxidation peak currents was observed in two concentration ranges of 0.004–3.5 mM and 3.5–9.0 mM. The detection limit was 2 μM at signal‐to‐noise ratio of 3. In addition to a fast response time (2/PGE sensor was successfully tested in the determination of glucose in human blood serum for the first time in the literature.
- 1 February 2018
- Published by Elsevier in Chinese Journal of Chemical Engineering
- Vol. 26 (2) , 421-427
Electrodeposition and characterization of Cu2O thin films using sodium thiosulfate as an additive for photovoltaic solar cells
- 1 February 2018
- Published by Elsevier in Chinese Journal of Chemical Engineering
- Vol. 26 (2) , 421-427
Electrodeposition and characterization of Cu2O thin films using sodium thiosulfate as an additive for photovoltaic solar cells