Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jingjin Zhang has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Research Progress of Grating-Based X-Ray Phase-Contrast Imaging and Key Devices

    by Fangke Zong, Jun Yang, Jinchuan Guo, Jingjin Zhang, Yang Du, Chenggong Zhang

    X-ray phase-contrast imaging presents a significant advancement in the field of X-ray imaging, surpassing traditional X-ray absorption imaging in detecting hydrogen substances. It effectively addresses the limitations of the latter in providing contrast for imaging weakly absorbing objects, thereby opening up vast potential applications in biomedical research, materials science, and industrial inspection. This article initially explores the fundamental principles of X-ray phase-contrast imaging and several prevalent imaging techniques. Notably, imaging devices such as grating-based Talbot–Lau interferometers emerge as the most promising in phase-contrast imaging due to their exceptional compatibility and imaging quality. Furthermore, this article introduces key parameters for assessing the quality of grating phase-contrast imaging, specifically image noise and sensitivity, along with their calculation methods. These insights are valuable for optimizing grating-based phase-contrast imaging devices. Lastly, this article examines potential applications and advancements in the key components of X-ray phase-contrast imaging while addressing current challenges and future directions in its technological development. This article aims to provide insights and inspiration for scholars interested in this field.


  • Open Access

    The Experimental Study of the Validity of the Lagrange–Helmholtz Relationship in Geomagnetic Fields

    by Jing-Jin Zhang, Yu-Wei Xu, Zeng-Zhou Yi, Qin-Lao Yang, Jun-Kun Huang, Fang-Ke Zong

    Streak cameras, known for their ultra-high spatiotemporal resolution, rely heavily on the spatial resolution capabilities of their core component, the streak tube, to ensure engineering stability. However, factors such as assembly inaccuracies and external magnetic fields, including geomagnetic interference, often cause deformation and shifts in the imaging plane. To enhance equipment stability and accelerate engineering advancements, a dual approach involving hardware improvements and computational imaging-based software corrections is essential. Future image reconstruction efforts in software require robust benchmarks; however, existing benchmarks are predominantly validated under idealized conditions, neglecting real-world interference factors. This study, grounded in electron optical imaging principles, experimentally confirms that the Lagrange–Helmholtz relationship remains valid within streak tube systems under geomagnetic field influences. These findings affirm that the imaging plane retains spatial resolution consistency despite such environmental disturbances. Consequently, the need for specific image orientations during reconstruction can be eliminated, enabling the development of more robust and efficient image reconstruction algorithms.

  • Open Access

    Simulation Design of an Electron Gun for Microchannel Plate Scrubbing

    by Zengzhou Yi, Yuwei Xu, Jingjin Zhang

    The microchannel plate (MCP) is susceptible to the adsorption of substantial amounts of gas during its fabrication process. To mitigate this, a uniform electron source is essential for effective electron scrubbing and gas removal. Thermionic emission, a method of electron generation, can be employed to create the electron source. In this study, a flat spiral filament was designed and simulated using the CST Studio Suite electron simulation software to assess the cleaning performance of the electron gun. The impact of variations in electron gun parameters on the uniformity of the electron beam and current density was systematically analysed. The simulation results show that, with filament, grid, focusing sleeve, and anode voltages set to 200 V, 500 V, 250 V, and 300 V, respectively, a uniform electron beam with a diameter exceeding 30 mm can be achieved. In order to obtain the current density (5~50 nA/mm2) required for the MCP, the temperature of the filament should be 1800–2000 K through theoretical calculation. These findings offer valuable insights for designing a more efficient electron gun for MCP scrubbing.

  • Design and Simulation of a Compact Sub-Nanosecond Pulse Generator Based on Marx’s Circuit Theory of Field-Effect Transistors

    by Wenyong Fu, Xindong Duan, Junkun Huang, Jingjin Zhang, Quanliang Guo, Houzhi Cai

    High-voltage ultrafast pulses can be effectively used to control the gated traveling-wave amplitude division of microchannel plates. In view of that and according to the microstrip transmission theory, this study proposes a pulse generator based on the Marx circuit of a field-effect tube. In this study, detailed designs of the proposed pulse generator are presented and validated by simulations using the OrCAD PSpice. An experimental setup is constructed to demonstrate the viability of the proposed design. Finally, an optimized pulse with a 2.2-kV amplitude and a 220-ps width is generated. This article provides a reference for future design of advanced direct capacitor discharge pulse generator with adjustable pulse parameters using the silicon carbide field effect.


  • Open Access

    Design and Experimental Study of a Large Beam Waist Streak Tube in an ICF Experiment

    by Hou-Zhi Cai, Xuan Deng, Li-Hong Niu, Qin-Lao Yang, Jing-Jin Zhang

    In order to realize in situ multi-frame framing, this paper designed and developed a large-waist framing converter tube. The size ratio between the waist and the object was about 1.16:1. The subsequent test results showed that the static spatial resolution of the tube could reach 10 lp/mm (@ 72.5%) under the premise of this adjustment, and the transverse magnification could reach 2.9. Once the MCP (Micro Channel Plate) traveling wave gating unit is equipped at the output end, it is expected to promote the further development of in situ multi-frame framing technology.


  • Open Access

    Experimental Study on Measuring Petzval Image Plane of Streak Tube with Single Image

    by Houzhi Cai, Yong Wang, Fangke Zong, Lihong Niu, Qinlao Yang, Jingjin Zhang

    In the process of image reconstruction of compressed sensing algorithms, building a measurement matrix related to the parameters of the imaging system is necessary to improve its imaging quality. Additionally, building a compressed ultrafast imaging system based on a streak camera, which includes aberrations in the imaging system, is necessary. However, the aberration coefficient of the streak tube can be obtained only by numerical calculation based on the known internal structure of the streak tube, and it does not apply to a tube with an unknown structure. Based on the Lagrange–Helmholtz relation, which is widely established in electronic optical imaging systems, this study proposes a method to obtain the Petzval image plane of a streak tube by measuring only a single image without considering the internal structure of the streak tube. This method provides a reference for the construction of the measurement matrix in the application of the compressed sensing algorithm; additionally, it provides a test scheme for the performance index of the streak tube after assembly in commercial production to further optimize the assembly process and improve the yield of production.

  • Open Access

    An Experimental Study Measuring the Image Field Angle of an Electron Beam Using a Streak Tube

    by Houzhi Cai, Xuan Deng, Lihong Niu, Qinlao Yang, Jingjin Zhang

    The final stage of an inertial confinement fusion (ICF) experiment requires the diagnostic instruments to have the ability to obtain multiple images with high spatiotemporal resolution due to its extremely short duration. However, the influence of field curvature in the streak tube may lead to resolution differences between each image from single line-of-sight (SLOS) technology. In order to achieve high-precision adaptive adjustments, the direction and depth of adjustment should be determined rapidly, which means that the diagnostic instrument must work within the image depth of field of its detector imaging system, requiring it to measure the image field angle of the electron beam. Here, a method based on the streak tube using the combination of planar and spherical fluorescent screens to directly calculate the image field angle of the electron beam from the rear image quality has been proposed for the first time, and its effectiveness has been proved by experiments. It is expected to provide a basis for the diagnostic equipment in ICF experiments to achieve adaptive high-precision adjustment of the focusing voltage to obtain a series of high-resolution images.


  • Open Access

    Secondary Amplifier Sampling Component Design of an X-ray Framing Detector Based on a Streak Tube

    by Jing-Jin Zhang, Yu-Wei Xu, Fang-Ke Zong, Li-Hong Niu, Bao-Guo Lei, Qin-Lao Yang, Hou-Zhi Cai

    The development of inertial confinement fusion (ICF) experiments necessitates the diagnostic instrument to have multiple frames with a high spatial and temporal resolution for the two-dimensional detection of the hot spot at the implosion end of the ICF. The existing sampling two-dimensional imaging technology in the world has superior performance; however, its subsequent development requires a streak tube with large lateral magnification. In this work, an electron beam separation device was designed and developed for the first time. The device can be used without changing the structure of the streak tube. It can be combined directly with the corresponding device and matched with a special control circuit. Based on the original transverse magnification, 1.77 times the secondary amplification can be achieved, which is conducive to expanding the recording range of the technology. The experimental results showed that the static spatial resolution of the streak tube after the inclusion of the device can still reach 10 lp/mm.