Taras Samchenko
Research Subjects
Taras Samchenko has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Oleksandr Nuianzin
National University of Civil Protection of Ukraine
3 shared publications - Aleksey Ratushnyy
Інститут державного управління та наукових досліджень з цивільного захисту
2 shared publications Cherkassy Institute of Fire Safety Named after Chernobyl Heroes ofNational University of Civil Defense of Ukraine
2 shared publications- Олександр Добростан
Інститут державного управління та наукових досліджень з цивільного захисту
2 shared publications - Alla Ziuzko
Mykolayiv National Agrarian University
1 shared publication - Anna Borysova
Institute of Scientific Research on Civil Protection of the National University of Civil Protection of Ukraine
1 shared publication
Latest Publications
- 8 July 2024
- Published by National University of Civil Protection of Ukraine in Scientific bulletin: Сivil protection and fire safety
- No. 1(17),p. 58-70
СТВОРЕННЯ ВИПРОБУВАЛЬНОГО ОБЛАДНАННЯ ДЛЯ ВИЗНАЧЕННЯ ПОВЕДІНКИ ПОКРИТТІВ ДЛЯ ПІДЛОГ ПІД ЧАС ГОРІННЯ З ВИКОРИСТАННЯМ ДЖЕРЕЛА ТЕПЛОВОГО ВИПРОМІНЮВАННЯ
Показана актуальність робіт з проведення випробувань з визначення поведінки покриттів для підлог під час горіння з використанням джерела теплового випромінювання для створення передумов щодо підвищення рівня пожежної безпеки об'єктів будівництва в Україні. Підтверджена доцільність запровадження в Україні європейської пожежної класифікації щодо реакції на вогонь покриттів для підлог. Вперше в Україні, на рівні європейських підходів, розроблено конструкцію та робочу конструкторську документацію випробувального обладнання для визначення поведінки покриттів для підлог під час горіння з використанням джерела теплового випромінювання. Визначено його технічні характеристики. Обґрунтовано та експериментально підтверджено параметри пальника для запалювання зразка, радіаційної панелі та системи для вимірювання оптичної щільності диму. Технічні характеристики створеного випробувального обладнання дозволяють проводити випробування зразків всіх типів покриттів для підлог. Наведено необхідні для проведення випробувань засоби вимірювальної техніки. Наведено процедуру калібрування випробувального обладнання, процедуру проведення випробувань та вимоги з оцінки результатів випробувань. Підготовлено матеріали для проведення верифікації випробувального обладнання, результати якої засвідчуватимуть гарантовані розробником та виробником випробувального обладнання основні параметри, технічні характеристики та дійсні значення нормованих метрологічних показників для випробувань покриттів для підлог під час горіння з використанням джерела теплового випромінювання згідно з вимогами та методикою наведеними у ДСТУ EN ISO 9239-1:2022.
- 8 July 2024
- Published by National University of Civil Protection of Ukraine in Scientific bulletin: Сivil protection and fire safety
- No. 1(17),p. 58-70
СТВОРЕННЯ ВИПРОБУВАЛЬНОГО ОБЛАДНАННЯ ДЛЯ ВИЗНАЧЕННЯ ПОВЕДІНКИ ПОКРИТТІВ ДЛЯ ПІДЛОГ ПІД ЧАС ГОРІННЯ З ВИКОРИСТАННЯМ ДЖЕРЕЛА ТЕПЛОВОГО ВИПРОМІНЮВАННЯ
Показана актуальність робіт з проведення випробувань з визначення поведінки покриттів для підлог під час горіння з використанням джерела теплового випромінювання для створення передумов щодо підвищення рівня пожежної безпеки об'єктів будівництва в Україні. Підтверджена доцільність запровадження в Україні європейської пожежної класифікації щодо реакції на вогонь покриттів для підлог. Вперше в Україні, на рівні європейських підходів, розроблено конструкцію та робочу конструкторську документацію випробувального обладнання для визначення поведінки покриттів для підлог під час горіння з використанням джерела теплового випромінювання. Визначено його технічні характеристики. Обґрунтовано та експериментально підтверджено параметри пальника для запалювання зразка, радіаційної панелі та системи для вимірювання оптичної щільності диму. Технічні характеристики створеного випробувального обладнання дозволяють проводити випробування зразків всіх типів покриттів для підлог. Наведено необхідні для проведення випробувань засоби вимірювальної техніки. Наведено процедуру калібрування випробувального обладнання, процедуру проведення випробувань та вимоги з оцінки результатів випробувань. Підготовлено матеріали для проведення верифікації випробувального обладнання, результати якої засвідчуватимуть гарантовані розробником та виробником випробувального обладнання основні параметри, технічні характеристики та дійсні значення нормованих метрологічних показників для випробувань покриттів для підлог під час горіння з використанням джерела теплового випромінювання згідно з вимогами та методикою наведеними у ДСТУ EN ISO 9239-1:2022.
- Open Access
- 30 April 2024
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 2 (6 (128)) , 14-19
Development of conditions for obtaining oil from sunflower oil hydration waste
The object of the study is the process of treatment of sunflower phosphatide concentrate using sodium chloride solution. Hydration is a stage of oil refining. The waste of the process is a phosphatide concentrate, the disposal of which is dangerous to the environment. The concentrate contains valuable components – oil and phosphatides. An important task is to separate these components for effective use in various industries. The process of extracting oil from phosphatide concentrate by hydration in the presence of sodium chloride solution was investigated. The influence of the concentrate treatment conditions on the oil yield was determined. A sample of concentrate according to SOU 15.4-37-212:2004 (CAS 3436-44-0) was used: mass fraction of moisture and volatile substances – 2.8 %, mass fraction of phosphatides – 41.5 %. The concentrate was treated with sodium chloride solution with a concentration of (5–20) %. The hydration time was 25 min., the temperature was 45 °C, and the mass ratio of the sodium chloride solution to the concentrate was 1:1. Conditions for the concentrate treatment were determined: the concentration of sodium chloride solution was 15 %, settling time was 5 hours. At the same time, the yield of oil was 86.9 %. The parameters of the extracted oil were determined: acid value 2.8 mg KOH/g, peroxide value 3.2 ½ O mmol/kg, mass fraction of moisture and volatile substances 0.12 %. According to these indicators, the extracted oil corresponds to first-grade unrefined unfrozen sunflower oil according to DSTU 4492. The mass fraction of phosphorus-containing substances in terms of stearooleolecithin was 1.7 %, which slightly exceeds the standard value. The research results make it possible to process hydration waste and obtain oil, which is a raw material for the products of many industries. This will help solve the problem of disposal of environmentally hazardous waste and improve the state of the environment
- 30 April 2024
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 2 (6 (128)) , 14-19
Open AccessDevelopment of conditions for obtaining oil from sunflower oil hydration waste
The object of the study is the process of treatment of sunflower phosphatide concentrate using sodium chloride solution. Hydration is a stage of oil refining. The waste of the process is a phosphatide concentrate, the disposal of which is dangerous to the environment. The concentrate contains valuable components – oil and phosphatides. An important task is to separate these components for effective use in various industries. The process of extracting oil from phosphatide concentrate by hydration in the presence of sodium chloride solution was investigated. The influence of the concentrate treatment conditions on the oil yield was determined. A sample of concentrate according to SOU 15.4-37-212:2004 (CAS 3436-44-0) was used: mass fraction of moisture and volatile substances – 2.8 %, mass fraction of phosphatides – 41.5 %. The concentrate was treated with sodium chloride solution with a concentration of (5–20) %. The hydration time was 25 min., the temperature was 45 °C, and the mass ratio of the sodium chloride solution to the concentrate was 1:1. Conditions for the concentrate treatment were determined: the concentration of sodium chloride solution was 15 %, settling time was 5 hours. At the same time, the yield of oil was 86.9 %. The parameters of the extracted oil were determined: acid value 2.8 mg KOH/g, peroxide value 3.2 ½ O mmol/kg, mass fraction of moisture and volatile substances 0.12 %. According to these indicators, the extracted oil corresponds to first-grade unrefined unfrozen sunflower oil according to DSTU 4492. The mass fraction of phosphorus-containing substances in terms of stearooleolecithin was 1.7 %, which slightly exceeds the standard value. The research results make it possible to process hydration waste and obtain oil, which is a raw material for the products of many industries. This will help solve the problem of disposal of environmentally hazardous waste and improve the state of the environment
- Open Access
- 1 January 2024
- Published by National University of Civil Protection of Ukraine in Emergency Situations: Prevention and Liquidation
- Vol. 8 (1) , 139-150
STUDY OF FIRE TEMPERATURE MODES IN HORIZONTAL CABLE TUNNELS DEPENDING ON PARAMETERS AND FIRE LOAD
Based on the results of the work, the dependences describing the maximum temperature inside the cable tunnel during a fire, the duration of a fire in a certain local area of the cable tunnel, and the time to reach the maximum temperature inside the cable tunnel during a fire were obtained from the fire load, the cross-sectional area ofthe tunnel, and the speed of movement of air masses inside.In one of the CFD software complexes, a mathematical model of the cable tunnel, similar to the real one, was created. A computational experiment was conducted. Modeling, as a method of scientific research, makes it possible to conduct all the necessary experiments on determining the temperature regimes of fire in cable tunnels without performing materially expensive and time-consuming field experiments on models.Based on the results of the computationalexperiment and field tests, adequacy criteria were calculated (Student's t-test, Cochran's Q-test, Fisher's F-criterion). Based on the analysis, the adequacy of the used mathematical models was investigated.A full factorial experiment was designed and conducted. According to its results, regressions of the maximum temperature inside the cable tunnel during a fire, the duration of a fire in a certain local area of the cable tunnel, and the time of reaching the maximum temperature inside the cable tunnel during a fire were obtained.The temperature regime of the fire in cable tunnels with different sizes, aerodynamic parameters and fire load was determined, as well as the dependence on the specified parameters of the temperature regime of the fire.
- 1 January 2024
- Published by National University of Civil Protection of Ukraine in Emergency Situations: Prevention and Liquidation
- Vol. 8 (1) , 139-150
Open AccessSTUDY OF FIRE TEMPERATURE MODES IN HORIZONTAL CABLE TUNNELS DEPENDING ON PARAMETERS AND FIRE LOAD
Based on the results of the work, the dependences describing the maximum temperature inside the cable tunnel during a fire, the duration of a fire in a certain local area of the cable tunnel, and the time to reach the maximum temperature inside the cable tunnel during a fire were obtained from the fire load, the cross-sectional area ofthe tunnel, and the speed of movement of air masses inside.In one of the CFD software complexes, a mathematical model of the cable tunnel, similar to the real one, was created. A computational experiment was conducted. Modeling, as a method of scientific research, makes it possible to conduct all the necessary experiments on determining the temperature regimes of fire in cable tunnels without performing materially expensive and time-consuming field experiments on models.Based on the results of the computationalexperiment and field tests, adequacy criteria were calculated (Student's t-test, Cochran's Q-test, Fisher's F-criterion). Based on the analysis, the adequacy of the used mathematical models was investigated.A full factorial experiment was designed and conducted. According to its results, regressions of the maximum temperature inside the cable tunnel during a fire, the duration of a fire in a certain local area of the cable tunnel, and the time of reaching the maximum temperature inside the cable tunnel during a fire were obtained.The temperature regime of the fire in cable tunnels with different sizes, aerodynamic parameters and fire load was determined, as well as the dependence on the specified parameters of the temperature regime of the fire.
- Open Access
- 1 June 2023
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Ecological Engineering & Environmental Technology
- Vol. 24 (4) , 138-146
Increasing the Efficiency and Environmental Friendliness of Fire Resistance Assessment Tools for Load-Bearing Reinforced Concrete Building Structures
In this work, it is substantiated that it is possible to create a fire installation with parameters that will ensure higher environmental friendliness of the tests compared to large-sized furnaces. At the same time, its configuration will be universal, compact and capable of high reproducibility...
- 1 June 2023
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Ecological Engineering & Environmental Technology
- Vol. 24 (4) , 138-146
Open AccessIncreasing the Efficiency and Environmental Friendliness of Fire Resistance Assessment Tools for Load-Bearing Reinforced Concrete Building Structures
In this work, it is substantiated that it is possible to create a fire installation with parameters that will ensure higher environmental friendliness of the tests compared to large-sized furnaces. At the same time, its configuration will be universal, compact and capable of high reproducibility...
- Open Access
- 1 January 2023
- Published by National University of Civil Protection of Ukraine in Emergency Situations: Prevention and Liquidation
- Vol. 7 (1) , 23-32
SCIENTIFIC BASIS OF THE CREATION AND APPLICATION OFEQUIPMENT FOR TESTING ROOFS FOR RESISTANCE TO EXTERNAL FIRE INFLUENCE
This article examines and analyzes the domestic and foreign regulatory framework, guidelines and technical documents, information brochures, manuals, handbooks, test protocols and other literary sources, information on the Internet. In the countries of the European space, fire safety requirements have been established for roofs and roofing materials, both for roofing materials and for roofs as part of structures, which helps to limit the spread of fire in buildings and structures during a fire. It has been proven that there is a need to create equipment for testing resistance to external fire exposure in accordance with DSTU CEN/TS 1187:2016 (method 2) covering buildings (roofs) and establishing fire classification according to DSTU EN 13501-5:2016. A passport, a technical description, an operating manual, a program and a stand verification method have been developed. The initial verification of the stand was carried out and it was put into operation. Approbation of the test method was carried out on the created stand through experimental studies of five types of roofing materials that are widely used on construction sites in Ukraine using two bases (substrates) of combustible and non-combustible material at air flow speeds of 2 m/s and 4 m /s above the sample surface. According to the results of this work, it was established that the maximum relative deviation of the result of measuring the length of the damaged (charred) part of the samples is in the range from 1.2% to 23.3% - for the roof and from 0.7% to 27.5% - for the base. У даній статті розглядаються і аналізуються вітчизняна та закордонна нормативна база, керівні та технічні документи, інформаційні проспекти, посібники, довідники, протоколи випробувань та інші літературні джерела, інформація мережі Internet. У країнах Європейського простору до покрівель та покрівельних матеріалів встановлено вимоги з пожежної безпеки як до покрівельних матеріалів так і до покрівель в складі конструкцій, що сприяє обмеженню поширення вогню в будівлях та спорудах під час пожежі. Доведено, що існує необхідність створення обладнання для проведення випробувань з визначення стійкості до зовнішнього вогневого впливу згідно з ДСТУ CEN/TS 1187:2016 (метод 2) покриття будівель (покрівлі) та встановлення пожежної класифікації згідно з ДСТУ EN 13501-5:2016. Розроблено паспорт, технічний опис, інструкцію з експлуатацію, програму та методику верифікації стенду. Здійснено первинну верифікацію стенду та введено його в експлуатацію. Виконано апробацію методу випробувань на створеному стенді шляхом проведених експериментальних досліджень п’яти видів покрівельних матеріалів, які широко застосовують на будівельних об’єктах України з використанням двох основ (підкладок) з горючого та негорючого матеріалу за швидкості повітряного потоку 2 м/с та 4 м/с над поверхнею зразка. За результатами даної роботи встановлено, що максимальне відносне відхилення результату вимірювання довжини пошкодженої (обвугленої) частини зразків знаходиться в межах від 1,2 % до 23,3 % – для покрівлі і від 0,7 % до 27,5 % – для основи.
- 1 January 2023
- Published by National University of Civil Protection of Ukraine in Emergency Situations: Prevention and Liquidation
- Vol. 7 (1) , 23-32
Open AccessSCIENTIFIC BASIS OF THE CREATION AND APPLICATION OFEQUIPMENT FOR TESTING ROOFS FOR RESISTANCE TO EXTERNAL FIRE INFLUENCE
This article examines and analyzes the domestic and foreign regulatory framework, guidelines and technical documents, information brochures, manuals, handbooks, test protocols and other literary sources, information on the Internet. In the countries of the European space, fire safety requirements have been established for roofs and roofing materials, both for roofing materials and for roofs as part of structures, which helps to limit the spread of fire in buildings and structures during a fire. It has been proven that there is a need to create equipment for testing resistance to external fire exposure in accordance with DSTU CEN/TS 1187:2016 (method 2) covering buildings (roofs) and establishing fire classification according to DSTU EN 13501-5:2016. A passport, a technical description, an operating manual, a program and a stand verification method have been developed. The initial verification of the stand was carried out and it was put into operation. Approbation of the test method was carried out on the created stand through experimental studies of five types of roofing materials that are widely used on construction sites in Ukraine using two bases (substrates) of combustible and non-combustible material at air flow speeds of 2 m/s and 4 m /s above the sample surface. According to the results of this work, it was established that the maximum relative deviation of the result of measuring the length of the damaged (charred) part of the samples is in the range from 1.2% to 23.3% - for the roof and from 0.7% to 27.5% - for the base. У даній статті розглядаються і аналізуються вітчизняна та закордонна нормативна база, керівні та технічні документи, інформаційні проспекти, посібники, довідники, протоколи випробувань та інші літературні джерела, інформація мережі Internet. У країнах Європейського простору до покрівель та покрівельних матеріалів встановлено вимоги з пожежної безпеки як до покрівельних матеріалів так і до покрівель в складі конструкцій, що сприяє обмеженню поширення вогню в будівлях та спорудах під час пожежі. Доведено, що існує необхідність створення обладнання для проведення випробувань з визначення стійкості до зовнішнього вогневого впливу згідно з ДСТУ CEN/TS 1187:2016 (метод 2) покриття будівель (покрівлі) та встановлення пожежної класифікації згідно з ДСТУ EN 13501-5:2016. Розроблено паспорт, технічний опис, інструкцію з експлуатацію, програму та методику верифікації стенду. Здійснено первинну верифікацію стенду та введено його в експлуатацію. Виконано апробацію методу випробувань на створеному стенді шляхом проведених експериментальних досліджень п’яти видів покрівельних матеріалів, які широко застосовують на будівельних об’єктах України з використанням двох основ (підкладок) з горючого та негорючого матеріалу за швидкості повітряного потоку 2 м/с та 4 м/с над поверхнею зразка. За результатами даної роботи встановлено, що максимальне відносне відхилення результату вимірювання довжини пошкодженої (обвугленої) частини зразків знаходиться в межах від 1,2 % до 23,3 % – для покрівлі і від 0,7 % до 27,5 % – для основи.