Hansong Gao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hansong Gao has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Zichao Wen
Washington University in St. Louis - School of Medicine
3 shared publications Haonan Xu
Department of Obstetrics & Gynecology, Washington University School of Medicine, St. Louis, USA
2 shared publications- Hui Wang
Department of Physics, Washington University, St. Louis, USA
2 shared publications - Wenjie Wu
Department of Biomedical Engineering, Washington University, St. Louis, USA
2 shared publications - Yiqi Lin
Department of Obstetrics & Gynecology, Washington University School of Medicine, St. Louis, USA
2 shared publications Yong Wang
2 shared publications
Latest Publications
- Open Access
- 12 May 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 123
Enhancing uterine contraction detection in electromyometrial imaging based on spatial continuity of the electric field
- 12 May 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 123
Open AccessEnhancing uterine contraction detection in electromyometrial imaging based on spatial continuity of the electric field
- Open Access
- 28 April 2025
- Published by Elsevier in SSRN Electronic Journal
Enhancing Uterine Contraction Detection in Electromyometrial Imaging Based on Spatial Continuity of the Electric Field
Preterm birth remains a critical global health challenge, leading to high mortality rates and long-term morbidity. Uterine contractions are a key factor in the onset of preterm labor, making accurate detection of uterine contractions crucial in managing preterm labor risk. Electromyometrial Imaging (EMMI) is a non-invasive imaging technique that provides high-resolution, three-dimensional maps of electrical activity on the uterine surface, offering both spatial and temporal resolution for monitoring uterine contractions. However, existing methods for analyzing EMMI data are susceptible to environmental noise and motion artifacts. This study introduces a novel approach to process EMMI data, effectively addressing the limitations of existing analysis methods. Our approach integrates motion artifact removal and uterine contraction detection using a kernel change point detection method that leverages global information to estimate the number of uterine contractions and local information to preserve the spatial continuity of the electric field. By leveraging the spatial structure of the uterine surface, our approach enhances robustness and accuracy in identifying uterine contractions. Extensive experiments were conducted to evaluate our approach to existing methods using three distinct metrics. The results highlight the superior performance of our approach, making a significant advancement in uterine contraction detection using EMMI data. This improved methodology has the potential to enhance early identification and management of preterm labor risks, contributing to efforts to reduce preterm birth rates and improve neonatal outcomes.
- 28 April 2025
- Published by Elsevier in SSRN Electronic Journal
Open AccessEnhancing Uterine Contraction Detection in Electromyometrial Imaging Based on Spatial Continuity of the Electric Field
Preterm birth remains a critical global health challenge, leading to high mortality rates and long-term morbidity. Uterine contractions are a key factor in the onset of preterm labor, making accurate detection of uterine contractions crucial in managing preterm labor risk. Electromyometrial Imaging (EMMI) is a non-invasive imaging technique that provides high-resolution, three-dimensional maps of electrical activity on the uterine surface, offering both spatial and temporal resolution for monitoring uterine contractions. However, existing methods for analyzing EMMI data are susceptible to environmental noise and motion artifacts. This study introduces a novel approach to process EMMI data, effectively addressing the limitations of existing analysis methods. Our approach integrates motion artifact removal and uterine contraction detection using a kernel change point detection method that leverages global information to estimate the number of uterine contractions and local information to preserve the spatial continuity of the electric field. By leveraging the spatial structure of the uterine surface, our approach enhances robustness and accuracy in identifying uterine contractions. Extensive experiments were conducted to evaluate our approach to existing methods using three distinct metrics. The results highlight the superior performance of our approach, making a significant advancement in uterine contraction detection using EMMI data. This improved methodology has the potential to enhance early identification and management of preterm labor risks, contributing to efforts to reduce preterm birth rates and improve neonatal outcomes.
- Open Access
- 19 July 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-14
Whole cervix imaging of collagen, muscle, and cellularity in term and preterm pregnancy
Cervical softening and dilation are critical for the successful term delivery of a fetus, with premature changes associated with preterm birth. Traditional clinical measures like transvaginal ultrasound and Bishop scores fall short in predicting preterm births and elucidating the cervix’s complex microstructural changes. Here, we introduce a magnetic resonance diffusion basis spectrum imaging (DBSI) technique for non-invasive, comprehensive imaging of cervical cellularity, collagen, and muscle fibers. This method is validated through ex vivo DBSI and histological analyses of specimens from total hysterectomies. Subsequently, retrospective in vivo DBSI analysis at 32 weeks of gestation in ten term deliveries and seven preterm deliveries with inflammation-related conditions shows distinct microstructural differences between the groups, alongside significant correlations with delivery timing. These results highlight DBSI’s potential to improve understanding of premature cervical remodeling and aid in the evaluation of therapeutic interventions for at-risk pregnancies. Future studies will further assess DBSI’s clinical applicability.
- 19 July 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-14
Open AccessWhole cervix imaging of collagen, muscle, and cellularity in term and preterm pregnancy
Cervical softening and dilation are critical for the successful term delivery of a fetus, with premature changes associated with preterm birth. Traditional clinical measures like transvaginal ultrasound and Bishop scores fall short in predicting preterm births and elucidating the cervix’s complex microstructural changes. Here, we introduce a magnetic resonance diffusion basis spectrum imaging (DBSI) technique for non-invasive, comprehensive imaging of cervical cellularity, collagen, and muscle fibers. This method is validated through ex vivo DBSI and histological analyses of specimens from total hysterectomies. Subsequently, retrospective in vivo DBSI analysis at 32 weeks of gestation in ten term deliveries and seven preterm deliveries with inflammation-related conditions shows distinct microstructural differences between the groups, alongside significant correlations with delivery timing. These results highlight DBSI’s potential to improve understanding of premature cervical remodeling and aid in the evaluation of therapeutic interventions for at-risk pregnancies. Future studies will further assess DBSI’s clinical applicability.
- Open Access
- 14 March 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-13
Noninvasive electromyometrial imaging of human uterine maturation during term labor
Electromyometrial imaging (EMMI) was recently developed to image the three-dimensional (3D) uterine electrical activation during contractions noninvasively and accurately in sheep. Herein we describe the development and application of a human EMMI system to image and evaluate 3D uterine electrical activation patterns at high spatial and temporal resolution during human term labor. We demonstrate the successful integration of the human EMMI system during subjects’ clinical visits to generate noninvasively the uterine surface electrical potential maps, electrograms, and activation sequence through an inverse solution using up to 192 electrodes distributed around the abdomen surface. Quantitative indices, including the uterine activation curve, are developed and defined to characterize uterine surface contraction patterns. We thus show that the human EMMI system can provide detailed 3D images and quantification of uterine contractions as well as novel insights into the role of human uterine maturation during labor progression.
- 14 March 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-13
Open AccessNoninvasive electromyometrial imaging of human uterine maturation during term labor
Electromyometrial imaging (EMMI) was recently developed to image the three-dimensional (3D) uterine electrical activation during contractions noninvasively and accurately in sheep. Herein we describe the development and application of a human EMMI system to image and evaluate 3D uterine electrical activation patterns at high spatial and temporal resolution during human term labor. We demonstrate the successful integration of the human EMMI system during subjects’ clinical visits to generate noninvasively the uterine surface electrical potential maps, electrograms, and activation sequence through an inverse solution using up to 192 electrodes distributed around the abdomen surface. Quantitative indices, including the uterine activation curve, are developed and defined to characterize uterine surface contraction patterns. We thus show that the human EMMI system can provide detailed 3D images and quantification of uterine contractions as well as novel insights into the role of human uterine maturation during labor progression.