NDNikhil Deveshwar

Nikhil Deveshwar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nikhil Deveshwar has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Synthesizing raw multicoil MRI data with a deep generative framework

    by Nikhil Deveshwar, Abhejit Rajagopal, Michael Lustig, Peder E Z Larson

    PurposeDeep learning–based magnetic resonance imaging (MRI) reconstruction can enable faster imaging and improved image quality; however, clinical adoption is limited by the lack of diverse raw multicoil training datasets. In routine clinical workflows, multicoil k-space data needed for training are often discarded, and only magnitude images are retained. In addition, phase is not deterministically recoverable from magnitude, and storing full k-space is impractical.ApproachWe address these limitations by (1) using a deep generative model to produce multiple plausible synthetic phase images conditioned on a single magnitude image and (2) introducing a radiofrequency (RF) coil library to synthesize multicoil k-space from the generated complex-valued images.ResultsThe synthetic phase images resemble ground-truth phase as assessed by Fréchet inception distance, and the generated multicoil k-space effectively trains unrolled MRI reconstruction networks.ConclusionsThese results indicate that generative phase synthesis coupled with an RF coil library provides a practical alternative to real multicoil k-space for training reconstruction models.

  • Open Access

    Deep Learning-Based Tumor Segmentation of Murine Magnetic Resonance Images of Prostate Cancer Patient-Derived Xenografts

    by Satvik Nayak, Henry Salkever, Ernesto Diaz, Avantika Sinha, Nikhil Deveshwar, Madeline Hess, Matthew Gibbons, Sule Sahin, Abhejit Rajagopal, Peder E. Z. Larson, et al.

    Background/Objective: Longitudinal in vivo studies of murine xenograft models are widely utilized in oncology to study cancer biology and develop therapies. Magnetic resonance imaging (MRI) of these tumors is an invaluable tool for monitoring tumor growth and characterizing the tumors as well. Methods: In this work, a pipeline for automating the segmentation of xenografts in mouse models was developed. T2-weighted (T2-wt) MRI images from mice implanted with six different prostate cancer patient-derived xenografts (PDX) in the kidneys, liver, and tibia were used. The segmentation pipeline included a slice classifier to identify the slices that had tumors and subsequent training and validation using several U-Net-based segmentation architectures. Multiple combinations of the algorithm and training images for different sites were evaluated for inference quality. Results and Conclusions: The slice classifier network achieved 90% accuracy in identifying slices containing tumors. Among the various segmentation architectures tested, the dense residual recurrent U-Net achieved the highest performance in kidney tumors. When evaluated across the kidneys, tibia, and liver, this architecture performed the best when trained on all data as compared to training on only data from a single site (and inferring on a multi-site tumor images), achieving a Dice score of 0.924 across the test set.


  • Scan-Specific Self-Supervised Bayesian Deep Non-Linear Inversion for Undersampled MRI Reconstruction

    by Andrew P. Leynes, Nikhil Deveshwar, Srikantan S. Nagarajan, Peder E. Z. Larson

    Magnetic resonance imaging is subject to slow acquisition times due to the inherent limitations in data sampling. Recently, supervised deep learning has emerged as a promising technique for reconstructing sub-sampled MRI. However, supervised deep learning requires a large dataset of fully-sampled data. Although unsupervised or self-supervised deep learning methods have emerged to address the limitations of supervised deep learning approaches, they still require a database of images. In contrast, scan-specific deep learning methods learn and reconstruct using only the sub-sampled data from a single scan. Here, we introduce Scan-Specific Self-Supervised Bayesian Deep Non-Linear Inversion (DNLINV) that does not require an auto calibration scan region. DNLINV utilizes a Deep Image Prior-type generative modeling approach and relies on approximate Bayesian inference to regularize the deep convolutional neural network. We demonstrate our approach on several anatomies, contrasts, and sampling patterns and show improved performance over existing approaches in scan-specific calibrationless parallel imaging and compressed sensing.


  • Quantification of the in vivo brain ultrashort‐T2* component in healthy volunteers

    by Nikhil Deveshwar, Jingwen Yao, Misung Han, Nicholas Dwork, Xin Shen, Emil Ljungberg, Eduardo Caverzasi, Peng Cao, Roland Henry, Ari Green, et al.

    Purpose: Recent work has shown MRI is able to measure and quantify signals of phospholipid membrane‐bound protons associated with myelin in the human brain. This work seeks to develop an improved technique for characterizing this brain ultrashort‐ component in vivo accounting for weighting.Methods: Data from ultrashort echo time scans from 16 healthy volunteers with variable flip angles (VFA) were collected and fitted into an advanced regression model to quantify signal fraction, relaxation time, and frequency shift of the ultrashort‐ component.Results: The fitted components show intra‐subject differences of different white matter structures and significantly elevated ultrashort‐ signal fraction in the corticospinal tracts measured at 0.09 versus 0.06 in other white matter structures and significantly elevated ultrashort‐ frequency shift in the body of the corpus callosum at 1.5 versus 2.0 ppm in other white matter structures.Conclusion: The significantly different measured components and measured relaxation time of the ultrashort‐ component suggest that this method is picking up novel signals from phospholipid membrane‐bound protons.


  • Open Access

    Pulmonary Ventilation Analysis Using 1 H Ultra-Short Echo Time (UTE) Lung MRI: A Reproducibility Study

    by Fei Tan, Xucheng Zhu, Marilynn Chan, Nikhil Deveshwar, Matthew M. Willmering, Michael Lustig, Peder Eric Zufall Larson

    Purpose: To evaluate methods for quantification of pulmonary ventilation with ultrashort echo time (UTE) MRI. Methods: We performed a reproducibility study, acquiring two free-breathing 1 H UTE lung MRIs on the same day for six healthy volunteers. The 1) 3D + t cyclic b-spline and 2) symmetric image normalization (SyN) methods for image registration were applied after respiratory phase-resolved image reconstruction. Ventilation maps were calculated using 1) Jacobian determinant of the deformation fields minus one, termed regional ventilation, and 2) intensity percentage difference between the registered and fixed image, termed specific ventilation. We compared the reproducibility of all four method combinations via statistical analysis. Results: Split violin plots and Bland-Altman plots are shown for whole lungs and lung sections. The cyclic b-spline registration and Jacobian determinant regional ventilation quantification provide total ventilation volumes that match the segmentation tidal volume, smooth and uniform ventilation maps. The cyclic b-spline registration and specific ventilation combination yields the smallest standard deviation in the Bland-Altman plot. Conclusion: Cyclic registration performs better than SyN for respiratory phase-resolved 1 H UTE MRI ventilation quantification. Regional ventilation correlates better with segmentation lung volume, while specific ventilation is more reproducible.


  • Open Access

    Synthesizing Complex-Valued Multicoil MRI Data from Magnitude-Only Images

    by Nikhil Deveshwar, Abhejit Rajagopal, Sule Sahin, Efrat Shimron, Peder E. Z. Larson

    Despite the proliferation of deep learning techniques for accelerated MRI acquisition and enhanced image reconstruction, the construction of large and diverse MRI datasets continues to pose a barrier to effective clinical translation of these technologies. One major challenge is in collecting the MRI raw data (required for image reconstruction) from clinical scanning, as only magnitude images are typically saved and used for clinical assessment and diagnosis. The image phase and multi-channel RF coil information are not retained when magnitude-only images are saved in clinical imaging archives. Additionally, preprocessing used for data in clinical imaging can lead to biased results. While several groups have begun concerted efforts to collect large amounts of MRI raw data, current databases are limited in the diversity of anatomy, pathology, annotations, and acquisition types they contain. To address this, we present a method for synthesizing realistic MR data from magnitude-only data, allowing for the use of diverse data from clinical imaging archives in advanced MRI reconstruction development. Our method uses a conditional GAN-based framework to generate synthetic phase images from input magnitude images. We then applied ESPIRiT to derive RF coil sensitivity maps from fully sampled real data to generate multi-coil data. The synthetic data generation method was evaluated by comparing image reconstruction results from training Variational Networks either with real data or synthetic data. We demonstrate that the Variational Network trained on synthetic MRI data from our method, consisting of GAN-derived synthetic phase and multi-coil information, outperformed Variational Networks trained on data with synthetic phase generated using current state-of-the-art methods. Additionally, we demonstrate that the Variational Networks trained with synthetic k-space data from our method perform comparably to image reconstruction networks trained on undersampled real k-space data.