Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jonas Paul David has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Design of a Safe Active Orthosis for Full Assistance of the Human Knee Joint

    by Jonas Paul David, Johannes Schick, Robin Neubauer, Markus Glaser

    Ensuring user safety while enabling independent mobility is crucial to autonomous healthcare and rehabilitation robots, such as active lower-limb orthoses and exoskeletons. A key requirement for these devices is to provide full assistance without supervision; however, existing designs do not simultaneously satisfy autonomous operation and inherent safety. To address this gap, a novel safety principle, Safety by Design, and a corresponding system architecture for a fully assistive active knee orthosis are introduced. The proposed architecture is based on a comprehensive risk analysis for the use of active orthoses and exoskeletons and integrates redundancies for all safety-critical components while minimizing additional weight. This redundancy enables the orthosis to remain operational at reduced power in the event of component failure, improving both user safety and system reliability. The design supports safe, unsupervised operation by ambulatory users, enhancing independent patient mobility and the performance of the gait activities of level walking, stair climbing and sitting down/standing up. The proposed architecture is scalable and adaptable to a wide range of robotic devices. By improving robustness, efficiency, and safety, this work contributes to the advancement of autonomous biomedical robotic systems and wearable assistive devices.

  • Open Access

    Conceptualization of Cloud-Based Motion Analysis and Navigation for Wearable Robotic Applications

    by David Schick, Johannes Schick, Jonas Paul David, Robin Neubauer, Markus Glaser

    The behavior of pedestrians in a non-constrained environment is difficult to predict. In wearable robotics, this poses a challenge, since devices like lower-limb exoskeletons and active orthoses need to support different walking activities, including level walking and climbing stairs. While a fixed movement trajectory can be easily supported, switches between these activities are difficult to predict. Moreover, the demand for these devices is expected to rise in the years ahead. In this work, we propose a cloud software system for use in wearable robotics, based on geographical mapping techniques and Human Activity Recognition (HAR). The system aims to give context to the surrounding pedestrians by providing hindsight information. The system was partially implemented and tested. The results indicate a viable concept with great extensibility prospects.


  • Open Access

    SensAA – Design and Verification of a Cloud-based Wearable Biomechanical Data Acquisition System

    by Jonas Paul David, David Schick, Lorenz Rapp, Johannes Schick, Markus Glaser

    Exoskeletons designed to assist patients with activities of daily living are becoming increasingly popular, but still are subject to research. In order to gather requirements for the design of such systems, long-term gait observation of the patients over the course of multiple days in an environment of daily living are required. In this paper a wearable all-in-one data acquisition system for collecting and storing biomechanical data in everyday life is proposed. The system is designed to be cost efficient and easy to use, using off-the-shelf components and a cloud server system for centralized data storage. The measurement accuracy of the system was verified, by measuring the angle of the human knee joint at walking speeds between 3 and 12 km/h in reference to an optical motion analysis system. The acquired data was uploaded to a cloud database via a smartphone application. Verification results showed that the proposed toolchain works as desired. The system reached an RMSE from 2.9° to 8°, which is below most of the comparable system. The system provides a powerful, scalable platform for collecting and processing biomechanical data, which can help to automize the generation of an extensive database for human kinematics.


  • Open Access

    SensAA—Design and Verification of a Cloud-Based Wearable Biomechanical Data Acquisition System

    by Jonas Paul David, David Schick, Lorenz Rapp, Johannes Schick, Markus Glaser

    Exoskeletons designed to assist patients with activities of daily living are becoming increasingly popular, but still are subject to research. In order to gather requirements for the design of such systems, long-term gait observation of the patients over the course of multiple days in an environment of daily living are required. In this paper a wearable all-in-one data acquisition system for collecting and storing biomechanical data in everyday life is proposed. The system is designed to be cost efficient and easy to use, using off-the-shelf components and a cloud server system for centralized data storage. The measurement accuracy of the system was verified, by measuring the angle of the human knee joint at walking speeds between 3 and 12 km/h in reference to an optical motion analysis system. The acquired data were uploaded to a cloud database via a smartphone application. Verification results showed that the proposed toolchain works as desired. The system reached an RMSE from 2.9° to 8°, which is below that of most comparable systems. The system provides a powerful, scalable platform for collecting and processing biomechanical data, which can help to automize the generation of an extensive database for human kinematics.


  • Open Access

    SenGlove—A Modular Wearable Device to Measure Kinematic Parameters of The Human Hand

    by Jonas Paul David, Thomas Helbig, Hartmut Witte

    For technical or medical applications, the knowledge of the exact kinematics of the human hand is key to utilizing its capability of handling and manipulating objects and communicating with other humans or machines. The optimal relationship between the number of measurement parameters, measurement accuracy, as well as complexity, usability and cost of the measuring systems is hard to find. Biomechanic assumptions, the concepts of a biomechatronic system and the mechatronic design process, as well as commercially available components, are used to develop a sensorized glove. The proposed wearable introduced in this paper can measure 14 of 15 angular values of a simplified hand model. Additionally, five contact pressure values at the fingertips and inertial data of the whole hand with six degrees of freedom are gathered. Due to the modular design and a hand size examination based on anthropometric parameters, the concept of the wearable is applicable to a large variety of hand sizes and adaptable to different use cases. Validations show a combined root-mean-square error of 0.99° to 2.38° for the measurement of all joint angles on one finger, surpassing the human perception threshold and the current state-of-the-art in science and technology for comparable systems.


  • Open Access

    SenGlove - A Modular Wearable Device To Measure Kinematic Parameters Of The Human Hand

    by Jonas David, Thomas Helbig, Hartmut Witte

    For technical or medical applications, the knowledge of the exact kinematics of the human hand is key to utilizing its capability to handle and manipulate objects and to communicate with other humans or machines. The optimal relationship between the number of measurement parameters, measurement accuracy as well as complexity, usability and cost of the measuring systems is hard to find. Biomechanic assumptions, the concepts of a biomechatronic system and the mechatronic design process as well as commercially available components are used to develop a sensorized glove. The proposed wearable can measure 14 of 15 angular values of a simplified hand model introduced in this paper. Additionally, five contact pressure values at the fingertips and inertial data of the whole hand with a degree of freedom of six are gathered. Due to the modular design and a hand size examination based on anthropometric parameters, the concept of the wearable is applicable for a large variety of hand sizes and adaptable to different use cases. Validations show a combined root-mean-square error of 0.99° to 2.38° for the measurement of all joint angles at one finger, surpassing the human perception threshold and the current state of the art in science and technology for comparable systems.