TWTeo Puig Walz

Teo Puig Walz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Teo Puig Walz has a total of 38 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Perivascular Excitation Tunnelling: a Novel and Preventable Cause of Cardiac Reperfusion Arrhythmias

    by Enaam Chleilat, Teo Puig Walz, Bo Han, T Alexander Quinn, Peter Kohl, Callum M Zgierski-Johnston

    Background: Reperfusion after myocardial ischaemia can lead to deadly arrhythmias, in part due to heterogeneities in electrophysiology (EP) across affected tissue. There is a need to understand the spatiotemporal dynamics of ischaemia-reperfusion arrhythmias (IRA), so that reperfusion strategies to prevent them can be found. Methods: Langendorff-perfused rabbit isolated hearts were loaded with a voltage-sensitive dye. Epifluorescence imaging was used to track action potential propagation across the cardiac surface. The heart was simultaneously perfused ‘globally’ ( via the aorta) and ‘locally’ ( via cannulation of a single coronary artery) with an oxygenated physiological saline solution. Local perfusion was subsequently switched to and from solutions that mimic aspects of ischaemia (acidosis, hypoxia, hyperkalaemia, or a simulated ischaemia solution combining all three) or to no-flow. Subsequently, different reperfusion strategies were tested to reduce IRA re-entries. The most successful strategy for preventing re-entry was tested in Langendorff-perfused isolated pig hearts to assess the clinical relevance of the observed mechanism and treatment strategy. Results: Upon sudden reperfusion of the cannulated coronary artery in rabbit hearts we observed a preferential recovery of electrical excitability along the vessel’s main branch (‘perivascular excitation tunnelling’, PVET). This resulted in re-entry in roughly half of the hearts. Hyperkalaemia and hypoxia, but not acidosis, were sufficient to lead to conduction block, PVET, and re-entry, with both PVET and re-entry more frequently observed after hyperkalaemia than hypoxia. PVET was also present in pigs and PVET-based re-entries were successfully prevented in rabbit and pig hearts by two-step reperfusion, first of the distal majority of the previously ischaemic region, and then of the remaining tissue from the proximal point. With this strategy, any PVET that developed in the distal tissue was blocked by the still inexcitable proximal tissue. Upon reperfusion of the proximal tissue, there was a reduced path length for PVET. As a consequence, the associated excitable gap was too short for re-entrant excitation. Conclusions: We observed a novel arrhythmia mechanism upon coronary reperfusion (PVET), which suggests that preferential recovery of myocardial excitability along the reperfused vessel is an important mechanism underlying IRA formation. PVET-induced re-entry reliably occurred in both rabbit and pig hearts and could be prevented by two-step reperfusion. Graphical


  • Open Access

    Mechano‐electrical interactions and heterogeneities in wild‐type and drug‐induced long QT syndrome rabbits

    by Raphaela D. Lewetag, Saranda Nimani, Nicolò Alerni, Tibor Hornyik, Simon F. Jacobi, Robin Moss, Marius Menza, Nicolas Pilia, Teo P. Walz, Amir HajiRassouliha, et al.

    Electromechanical reciprocity – comprising electro‐mechanical (EMC) and mechano‐electric coupling (MEC) – provides cardiac adaptation to changing physiological demands. Understanding electromechanical reciprocity and its impact on function and heterogeneity in pathological conditions – such as (drug‐induced) acquired long QT syndrome (aLQTS) – might lead to novel insights in arrhythmogenesis. Our aim is to investigate how electrical changes impact on mechanical function (EMC) and vice versa (MEC) under physiological conditions and in aLQTS. To measure regional differences in EMC and MEC in vivo, we used tissue phase mapping cardiac MRI and a 24‐lead ECG vest in healthy (control) and IKr‐blocker E‐4031‐induced aLQTS rabbit hearts. MEC was studied in vivo by acutely increasing cardiac preload, and ex vivo by using voltage optical mapping (OM) in beating hearts at different preloads. In aLQTS, electrical repolarization (heart rate corrected RT‐interval, RTn370) was prolonged compared to control (P < 0.0001) with increased spatial and temporal RT heterogeneity (P < 0.01). Changing electrical function (in aLQTS) resulted in significantly reduced diastolic mechanical function and prolonged contraction duration (EMC), causing increased apico‐basal mechanical heterogeneity. Increased preload acutely prolonged RTn370 in both control and aLQTS hearts (MEC). This effect was more pronounced in aLQTS (P < 0.0001). Additionally, regional RT‐dispersion increased in aLQTS. Motion‐correction allowed us to determine APD‐prolongation in beating aLQTS hearts, but limited motion correction accuracy upon preload‐changes prevented a clear analysis of MEC ex vivo. Mechano‐induced RT‐prolongation and increased heterogeneity were more pronounced in aLQTS than in healthy hearts. Acute MEC effects may play an additional role in LQT‐related arrhythmogenesis, warranting further mechanistic investigations. image Key points: Electromechanical reciprocity comprising excitation‐contraction coupling (EMC) and mechano‐electric feedback loops (MEC) is essential for physiological cardiac function. Alterations in electrical and/or mechanical heterogeneity are known to have potentially pro‐arrhythmic effects. In this study, we aimed to investigate how electrical changes impact on the mechanical function (EMC) and vice versa (MEC) both under physiological conditions (control) and in acquired long QT syndrome (aLQTS). We show that changing the electrical function (in aLQTS) results in significantly altered mechanical heterogeneity via EMC and, vice versa, that increasing the preload acutely prolongs repolarization duration and increases electrical heterogeneity, particularly in aLQTS as compared to control. Our results substantiate the hypothesis that LQTS is an ‛electro‐mechanical’, rather than a ‘purely electrical’, disease and suggest that acute MEC effects may play an additional role in LQT‐related arrhythmogenesis.


  • Open Access

    Influence of the Nature of Aminoalcohol on ZnO Films Formed by Sol-Gel Methods

    by Anna Vilà, Alberto Gómez-Núñez, Xavier Alcobé, Sergi Palacios, Teo Puig Walz, Concepción López

    Here we present comparative studies of: (i) the formation of ZnO thin films via the sol-gel method using zinc acetate dihydrate (ZAD), 2-methoxyethanol (ME) as solvent, and the aminoalcohols (AA): ethanolamine, (S)-(+)-2-amino-1-propanol, (S)-(+)-2-amino-3-methyl-1-butanol, 2-aminophenol, and aminobenzyl alcohol, and (ii) elemental analyses, infrared spectroscopy, X-ray diffraction, scanning electron microscopy, absorption and emission spectra of films obtained after deposition by drop coating on glass surface, and thermal treatments at 300, 400, 500 and 600 °C. The results obtained provide conclusive evidences of the influence of the AA used (aliphatic vs. aromatic) on the ink stability (prior to deposition), and on the composition, structures, morphologies, and properties of films after calcination, in particular, those due to the different substituents, H, Me, or iPr, and to the presence or the absence of a –CH2 unit. Aliphatic films, more stable and purer than aromatic ones, contained the ZnO wurtzite form for all annealing temperatures, while the cubic sphalerite (zinc-blende) form was also detected after using aromatic AAs. Films having frayed fibers or quartered layers or uniform yarns evolved to “neuron-like” patterns. UV and photoluminescence studies revealed that these AAs also affect the optical band gap, the structural defects, and photo-optical properties of the films.


  • Dynamically Resolving and Abstracting Markov Models for System Resilience Analysis

    by Ivo Häring, Nikhilesh Sandela, Teo Puig Walz, Georg Vogelbacher, Alexander Richter, Aishvarya Kumar Jain, Mayur Dhanani, Sunil Mopuru, Konstantin Kirchheim, Fabian Höflinger, et al.

  • Overall Markov Diagram Design and Simulation Example for Scalable Safety Analysis of Autonomous Vehicles

    by Ivo Häring, Sunil Kumar Reddy Mopuru, Teo Puig Walz, Mayur Dhanani, Nikhilesh Sandela, Jörg Finger, Georg Vogelbacher, Fabian Höflinger, Aishvarya Kumar Jain, Alexander Richter, et al.