Martina Moglioni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Martina Moglioni has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
- Alessandra Retico
National Institute for Nuclear Physics (INFN), Pisa Division, 56127 Pisa, Italy
4 shared publications - Francesco Pennazio
Istituto Nazionale di Fisica Nucleare Sezione di Torino, Via Pietro Giuria 1, Turin, Piedmont, 10125, Italy
4 shared publications Elisa Fiorina
Istituto Nazionale di Fisica Nucleare, Sezione di Torino, Via Pietro Giuria 1, 10125 Torino, Italy
3 shared publications- Maria Giuseppina Bisogni
Department of Physics, University of Pisa and INFN Sezione di Pisa, Pisa, Italy
3 shared publications - Piergiorgio Cerello
Istituto Nazionale di Fisica Nucleare Sezione di Torino, Via Pietro Giuria 1, Turin, Piedmont, 10125, Italy
3 shared publications - Veronica Ferrero
Universita degli Studi di Torino, Via Pietro Giuria 1, Turin, Piedmont, 10124, Italy
3 shared publications
Latest Publications
- Open Access
- 13 April 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (9) , 095004
Micro CT calibration accuracy for pre-clinical studies in ion therapy
Objective: Accurate estimation of tissue stopping power ratios (SPR) from computed tomography (CT) data is essential in charged particle therapy (CPT), yet it remains a major source of range uncertainties. While various SPR calibration methods have been developed for clinical CT scanners, they are not tailored to cone beam type Micro CT scanners commonly used in pre-clinical studies involving small animals. This work aims to assess how different clinical SPR calibration methods influence range predictions in small animal CPT pre-clinical trials, evaluated at both the voxel and organ levels. Approach: A small animal calibration phantom was imaged with a Micro CT at X-ray tube voltages between 45 kV and 70 kV. The images were used in two single energy (SECT), a stoichiometric and a simplified method, and one stoichiometric dual energy (DECT) calibration method. The accuracy of SPR predictions for each method was evaluated using simulated CT images of murine head, thorax, and abdomen virtual phantoms derived from in vivo data. Main results: Both SECT methods were found to yield comparable accuracy in the head and abdomen areas. Root mean squared (RMS) errors to the nominal SPR values were found to be 5.04% and 4.22% in the head phantom and 2.31% and 2.61% in the abdomen phantom, for the stoichiometric and simplified SECT method, respectively. RMS errors in the lung phantom were found to be 16.42% and 35.80%. The stoichiometric DECT method was found to improve accuracy in the lung phantom to 12.37% while in the head phantom it achieved 19.37% and in the abdomen 6.42%. Significance: This is the first report of treatment plan agnostic low-kV Micro CT SPR calibration accuracy. It can provide a reference for expected SPR and range uncertainties in pre-clinical CPT trials.
- 13 April 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (9) , 095004
Open AccessMicro CT calibration accuracy for pre-clinical studies in ion therapy
Objective: Accurate estimation of tissue stopping power ratios (SPR) from computed tomography (CT) data is essential in charged particle therapy (CPT), yet it remains a major source of range uncertainties. While various SPR calibration methods have been developed for clinical CT scanners, they are not tailored to cone beam type Micro CT scanners commonly used in pre-clinical studies involving small animals. This work aims to assess how different clinical SPR calibration methods influence range predictions in small animal CPT pre-clinical trials, evaluated at both the voxel and organ levels. Approach: A small animal calibration phantom was imaged with a Micro CT at X-ray tube voltages between 45 kV and 70 kV. The images were used in two single energy (SECT), a stoichiometric and a simplified method, and one stoichiometric dual energy (DECT) calibration method. The accuracy of SPR predictions for each method was evaluated using simulated CT images of murine head, thorax, and abdomen virtual phantoms derived from in vivo data. Main results: Both SECT methods were found to yield comparable accuracy in the head and abdomen areas. Root mean squared (RMS) errors to the nominal SPR values were found to be 5.04% and 4.22% in the head phantom and 2.31% and 2.61% in the abdomen phantom, for the stoichiometric and simplified SECT method, respectively. RMS errors in the lung phantom were found to be 16.42% and 35.80%. The stoichiometric DECT method was found to improve accuracy in the lung phantom to 12.37% while in the head phantom it achieved 19.37% and in the abdomen 6.42%. Significance: This is the first report of treatment plan agnostic low-kV Micro CT SPR calibration accuracy. It can provide a reference for expected SPR and range uncertainties in pre-clinical CPT trials.
- 12 August 2024
- Published by Elsevier in Physica Medica
- Vol. 125, 104493
In-beam PET treatment monitoring of carbon therapy patients: Results of a clinical trial at CNAO
- 12 August 2024
- Published by Elsevier in Physica Medica
- Vol. 125, 104493
In-beam PET treatment monitoring of carbon therapy patients: Results of a clinical trial at CNAO
- Open Access
- 15 March 2024
- Published by Elsevier in Physica Medica
- Vol. 120, 103329
Using the gamma-index analysis for inter-fractional comparison of in-beam PET images for head-and-neck treatment monitoring in proton therapy: A Monte Carlo simulation study
- 15 March 2024
- Published by Elsevier in Physica Medica
- Vol. 120, 103329
Open AccessUsing the gamma-index analysis for inter-fractional comparison of in-beam PET images for head-and-neck treatment monitoring in proton therapy: A Monte Carlo simulation study
- Open Access
- 13 March 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (6) , 065011
Synthetic CT imaging for PET monitoring in proton therapy: a simulation study
Objective. This study addresses a fundamental limitation of in-beam positron emission tomography (IB-PET) in proton therapy: the lack of direct anatomical representation in the images it produces. We aim to overcome this shortcoming by pioneering the application of deep learning techniques to create synthetic control CT images (sCT) from combining IB-PET and planning CT scan data. Approach. We conducted simulations involving six patients who underwent irradiation with proton beams. Leveraging the architecture of a visual transformer (ViT) neural network, we developed a model to generate sCT images of these patients using the planning CT scans and the inter-fractional simulated PET activity maps during irradiation. To evaluate the model’s performance, a comparison was conducted between the sCT images produced by the ViT model and the authentic control CT images—serving as the benchmark. Main results. The structural similarity index was computed at a mean value across all patients of 0.91, while the mean absolute error measured 22 Hounsfield Units (HU). Root mean squared error and peak signal-to-noise ratio values were 56 HU and 30 dB, respectively. The Dice similarity coefficient exhibited a value of 0.98. These values are comparable to or exceed those found in the literature. More than 70% of the synthetic morphological changes were found to be geometrically compatible with the ones reported in the real control CT scan. Significance. Our study presents an innovative approach to surface the hidden anatomical information of IB-PET in proton therapy. Our ViT-based model successfully generates sCT images from inter-fractional PET data and planning CT scans. Our model’s performance stands on par with existing models relying on input from cone beam CT or magnetic resonance imaging, which contain more anatomical information than activity maps.
- 13 March 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (6) , 065011
Open AccessSynthetic CT imaging for PET monitoring in proton therapy: a simulation study
Objective. This study addresses a fundamental limitation of in-beam positron emission tomography (IB-PET) in proton therapy: the lack of direct anatomical representation in the images it produces. We aim to overcome this shortcoming by pioneering the application of deep learning techniques to create synthetic control CT images (sCT) from combining IB-PET and planning CT scan data. Approach. We conducted simulations involving six patients who underwent irradiation with proton beams. Leveraging the architecture of a visual transformer (ViT) neural network, we developed a model to generate sCT images of these patients using the planning CT scans and the inter-fractional simulated PET activity maps during irradiation. To evaluate the model’s performance, a comparison was conducted between the sCT images produced by the ViT model and the authentic control CT images—serving as the benchmark. Main results. The structural similarity index was computed at a mean value across all patients of 0.91, while the mean absolute error measured 22 Hounsfield Units (HU). Root mean squared error and peak signal-to-noise ratio values were 56 HU and 30 dB, respectively. The Dice similarity coefficient exhibited a value of 0.98. These values are comparable to or exceed those found in the literature. More than 70% of the synthetic morphological changes were found to be geometrically compatible with the ones reported in the real control CT scan. Significance. Our study presents an innovative approach to surface the hidden anatomical information of IB-PET in proton therapy. Our ViT-based model successfully generates sCT images from inter-fractional PET data and planning CT scans. Our model’s performance stands on par with existing models relying on input from cone beam CT or magnetic resonance imaging, which contain more anatomical information than activity maps.
- 15 March 2023
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1051, 168206
MLS analysis of INSIDE in-beam PET images for the detection of morphological changes in patients treated with protontherapy
- 15 March 2023
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1051, 168206
MLS analysis of INSIDE in-beam PET images for the detection of morphological changes in patients treated with protontherapy