A. V. Fomin
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
A. V. Fomin has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- R. B. Shaimov
Center Zreniya
3 shared publications - Timur Bulatovich Shaimov
Center Zreniya
3 shared publications - Venera A. Shaimova
Academy of Postgraduate Education of Federal Medical Biological Agency; Center Zreniya
3 shared publications - G. R. Islamova
Center Zreniya
2 shared publications S.KH. Kuchkildina
OOO Centr Zreniya
2 shared publications- Vladimir N. Trubilin
Diagnostic Department of Ophthalmological Center of Federal Medical-Biological Agency; Academy of Postgraduate Education of Federal Medical and Biological Agency
2 shared publications
Latest Publications
- 28 August 2023
- Published by Media Sphere Publishing Group in Russian Annals of Ophthalmology
- Vol. 139 (4) , 65-70
Subthreshold micropulse laser treatment of the foveal region in chronic central serous chorioretinopathy (case study)
The article presents a clinical case of subthreshold micropulse laser (SML) treatment of chronic central serous chorioretinopathy (CSC) in the left eye of a 44-year-old female patient K. with dye allergy. The patient first noticed a gray spot, distortion of objects in February, 2018. During 2018—2020 she suffered 5 relapses, repeated unsuccessful conservative treatment, and completed a course of antiangiogenic therapy in the form of three monthly intravitreal injections of ranibizumab. After experiencing stress on 11.08.20 she noted acute deterioration. Laser treatment was carried out on 20.09.20 with the Navilas 577s navigation system (wavelength 577 nm). After the power titration and calculation, the contact-free subthreshold micropulse laser treatment was carried out without anesthesia in three zones: 200 mW for fovea, 240 mW for parafovea and 340 mW for periphovea. Other settings: pulse duration — 200 ms, spot diameter — 100 µm, duty cycle — 5%. Total number of laser pulses — 1000. The retina reattached completely despite the patient having previously recovered from the coronavirus infection and the use of corticosteroids.
- 28 August 2023
- Published by Media Sphere Publishing Group in Russian Annals of Ophthalmology
- Vol. 139 (4) , 65-70
Subthreshold micropulse laser treatment of the foveal region in chronic central serous chorioretinopathy (case study)
The article presents a clinical case of subthreshold micropulse laser (SML) treatment of chronic central serous chorioretinopathy (CSC) in the left eye of a 44-year-old female patient K. with dye allergy. The patient first noticed a gray spot, distortion of objects in February, 2018. During 2018—2020 she suffered 5 relapses, repeated unsuccessful conservative treatment, and completed a course of antiangiogenic therapy in the form of three monthly intravitreal injections of ranibizumab. After experiencing stress on 11.08.20 she noted acute deterioration. Laser treatment was carried out on 20.09.20 with the Navilas 577s navigation system (wavelength 577 nm). After the power titration and calculation, the contact-free subthreshold micropulse laser treatment was carried out without anesthesia in three zones: 200 mW for fovea, 240 mW for parafovea and 340 mW for periphovea. Other settings: pulse duration — 200 ms, spot diameter — 100 µm, duty cycle — 5%. Total number of laser pulses — 1000. The retina reattached completely despite the patient having previously recovered from the coronavirus infection and the use of corticosteroids.
- Open Access
- 26 March 2023
- Published by Skobelkin State Scientific Center of Laser Medicine in Laser Medicine
- Vol. 26 (3-4) , 56-67
Improving TransPRK surgery with Microscan Visum 1100 Hz device for myopia correction
Transepithelial photorefractive keratectomy (TransPRK) with excimer laser “Microscan Visum” (1100 Hz) is a one-stage surgery which does not require changing the sequence of stages for epithelium removal and ablation of cornea stromal part. The “know-how” of Russian excimer laser manufacturers allows to significantly reduce corneal tissue overheating during TransPRK surgery. A new approach to TransPRK surgery consists in simultaneous use of Platoscan program, age nomogram and size of epithelium initial thickness.Purpose: to assess functional outcomes and changes in the corneal epithelium thickness after TransPRK surgery in patients with myopia in the period from 1 month to 1 year.Material and methods. Sixty-six eyes of 33 patients were included in the trial. Average patients’ age was 25.6 ± 6.8 (mean 17–40); 18 men and 15 women. The average spherical component was –2.57 ± 1.54 diopters (from –0.75 to –5.75). The average cylindrical component before surgery was –0.79 ± 0.71 diopters (from 0.00 to –3.5); 45 eyes with mild myopia, 21 eyes with moderate myopia. Epithelium thickness was measured with RTVue-xR Avanti device (Optovue, USA). Calculations were made using Platoscan program and age nomogram (OOO “Opto-systems”, Russia). Assessment of functional outcomes was made using generally accepted standards in refractive surgery.Results. TransPRK has shown its high efficacy, safety, predictability and accuracy in patients with myopia correction. Analysis of OCT findings of the anterior segment using epithelial maps showed that there is no complete restoration of epithelium thickness both in cornea center and in cornea periphery in 7-mm zone by the end of the first month after TransPRK surgery. In one month after TransPRK, epithelium thickness restored by 86.64 % in the center and by 87.99 % in 7-mm zone. Complete restoration of epithelium thickness in the center and in periphery was reached in 6 months. Corneal epithelium thickness in the surgical field increased by 7.9 % both in the center and in periphery in 12 months after the surgery. The ratio of epithelium initial thickness in the center and in periphery to the total cornea thickness before and after the surgery was 10–12 % for the entire study period.
- 26 March 2023
- Published by Skobelkin State Scientific Center of Laser Medicine in Laser Medicine
- Vol. 26 (3-4) , 56-67
Open AccessImproving TransPRK surgery with Microscan Visum 1100 Hz device for myopia correction
Transepithelial photorefractive keratectomy (TransPRK) with excimer laser “Microscan Visum” (1100 Hz) is a one-stage surgery which does not require changing the sequence of stages for epithelium removal and ablation of cornea stromal part. The “know-how” of Russian excimer laser manufacturers allows to significantly reduce corneal tissue overheating during TransPRK surgery. A new approach to TransPRK surgery consists in simultaneous use of Platoscan program, age nomogram and size of epithelium initial thickness.Purpose: to assess functional outcomes and changes in the corneal epithelium thickness after TransPRK surgery in patients with myopia in the period from 1 month to 1 year.Material and methods. Sixty-six eyes of 33 patients were included in the trial. Average patients’ age was 25.6 ± 6.8 (mean 17–40); 18 men and 15 women. The average spherical component was –2.57 ± 1.54 diopters (from –0.75 to –5.75). The average cylindrical component before surgery was –0.79 ± 0.71 diopters (from 0.00 to –3.5); 45 eyes with mild myopia, 21 eyes with moderate myopia. Epithelium thickness was measured with RTVue-xR Avanti device (Optovue, USA). Calculations were made using Platoscan program and age nomogram (OOO “Opto-systems”, Russia). Assessment of functional outcomes was made using generally accepted standards in refractive surgery.Results. TransPRK has shown its high efficacy, safety, predictability and accuracy in patients with myopia correction. Analysis of OCT findings of the anterior segment using epithelial maps showed that there is no complete restoration of epithelium thickness both in cornea center and in cornea periphery in 7-mm zone by the end of the first month after TransPRK surgery. In one month after TransPRK, epithelium thickness restored by 86.64 % in the center and by 87.99 % in 7-mm zone. Complete restoration of epithelium thickness in the center and in periphery was reached in 6 months. Corneal epithelium thickness in the surgical field increased by 7.9 % both in the center and in periphery in 12 months after the surgery. The ratio of epithelium initial thickness in the center and in periphery to the total cornea thickness before and after the surgery was 10–12 % for the entire study period.
- 16 March 2023
- Published by Media Sphere Publishing Group in Russian Annals of Ophthalmology
- Vol. 139 (1) , 93-98
Widefield optical coherence tomography as an effective method for detecting imperceptible flap retinal tears (clinical observation)
Certain late peripheral ruptures after acute posterior vitreous detachment (PVD) may remain undetected during the initial examination of the fundus due to the presence of vitreous hemorrhages and other factors, but they can lead to rhegmatogenic retinal detachment in the future. Hence, it is necessary to conduct an additional thorough examination using optical coherence tomography (OCT) of the vitreoretinal interface periphery in the presence of tear predictors: retinal and vitreal hemorrhages, vitreous pigment cells (“tobacco dust”) in the anterior segment of the vitreous body, as well as hyper-reflective dots (“starry sky”) in the vitreous body according to OCT scans of patients with acute symptomatic detachment of the hyaloid membrane. The article presents the case of a patient with a clinically imperceptible flap tear detected during acute posterior vitreous detachment. Widefield OCT of the vitreoretinal interface was performed by “sliding” from the center to the periphery of the retina, and revealed a flap tear located next to a dot retinal hemorrhage. OCT scanning of the retinal periphery is an effective modern diagnostic method in the ophthalmological clinical practice.
- 16 March 2023
- Published by Media Sphere Publishing Group in Russian Annals of Ophthalmology
- Vol. 139 (1) , 93-98
Widefield optical coherence tomography as an effective method for detecting imperceptible flap retinal tears (clinical observation)
Certain late peripheral ruptures after acute posterior vitreous detachment (PVD) may remain undetected during the initial examination of the fundus due to the presence of vitreous hemorrhages and other factors, but they can lead to rhegmatogenic retinal detachment in the future. Hence, it is necessary to conduct an additional thorough examination using optical coherence tomography (OCT) of the vitreoretinal interface periphery in the presence of tear predictors: retinal and vitreal hemorrhages, vitreous pigment cells (“tobacco dust”) in the anterior segment of the vitreous body, as well as hyper-reflective dots (“starry sky”) in the vitreous body according to OCT scans of patients with acute symptomatic detachment of the hyaloid membrane. The article presents the case of a patient with a clinically imperceptible flap tear detected during acute posterior vitreous detachment. Widefield OCT of the vitreoretinal interface was performed by “sliding” from the center to the periphery of the retina, and revealed a flap tear located next to a dot retinal hemorrhage. OCT scanning of the retinal periphery is an effective modern diagnostic method in the ophthalmological clinical practice.
- Open Access
- 1 January 2018
- Published by Media Sphere Publishing Group in Russian Annals of Ophthalmology
- Vol. 134 (1) , 56-62
Evaluation of YAG-laser vitreolysis effectiveness based on quantitative characterization of vitreous floaters
Medical article медицинская статья
- 1 January 2018
- Published by Media Sphere Publishing Group in Russian Annals of Ophthalmology
- Vol. 134 (1) , 56-62
Open AccessEvaluation of YAG-laser vitreolysis effectiveness based on quantitative characterization of vitreous floaters
Medical article медицинская статья