Ana Macarro-Merino
Ana Macarro-Merino has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- José Ignacio Fernández-Vigo
Ophthalmology, Hospital Universitario Clinico San Carlos, Madrid, Spain
7 shared publications - Lucía De-Pablo-Gómez-De-Liaño
Department of Ophthalmology, Hospital Universitario 12 de Octubre, 28041 Madrid, Spain
6 shared publications - Barbara Burgos-Blasco
Department of Ophthalmology, Hospital Clínico San Carlos, Madrid, Spain
4 shared publications - Ignacio Almorín-Fernández-Vigo
Centro Internacional de Oftalmología Avanzada, 06010 Badajoz, Spain
4 shared publications - Inés Sánchez-Guillén
Department of Ophthalmology, Hospital Perpetuo Socorro, 06010 Badajoz, Spain
4 shared publications - Beatriz De-Pablo-Gómez-De-Liaño
Hospital Central de la Cruz Roja San José y Santa Adela
2 shared publications
Latest Publications
- Open Access
- 1 March 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (5) , 733
Agreement Between Two Swept-Source Optical Coherence Tomography Devices in Assessing Glistening on the Intraocular Lens In Vivo
Background/Objectives: To analyze the agreement between two swept-source optical coherence tomography (SS-OCT) devices in assessing glistening on intraocular lenses (IOL). Methods: Patients who had previously undergone cataract surgery were included. They were sequentially examined using two SS-OCT devices: Anterion (Heidelberg Engineering Inc., Heidelberg, Germany) and Triton (Topcon, Inc., Tokyo, Japan). Six corresponding scans from both devices were compared, and glistening, observed as hyperreflective foci (HRF), was manually counted. The total number of HRF and the degree of glistening were measured and categorized into four groups. The agreement between the two devices was analyzed using the intraclass correlation coefficient (ICC). Results: A total of 333 eyes from 285 patients were evaluated. The mean age was 76.5 ± 8.0 years (range: 45–95). The median number of HRF detected in a single scan was 1.1 (IQR 0.0–10.2, range 0–176) using Triton and 2.7 (IQR 0.2–20.1, range 0–250) using Anterion. The ICC across different scans ranged from 0.8 to 0.9, indicating strong agreement between the two devices. Bland–Altman plots showed better concordance in lenses with low glistening grades, while higher grades revealed greater discrepancies, with Anterion detecting significantly more HRF than Triton. Among all factors studied, only postsurgical time was associated with glistening. Conclusions: Two different SS-OCT devices can detect and quantify glistening in IOLs. The concordance between them was high, particularly for lower glistening grades. However, in higher grades, Anterion detected significantly more HRF than Triton.
- 1 March 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (5) , 733
Open AccessAgreement Between Two Swept-Source Optical Coherence Tomography Devices in Assessing Glistening on the Intraocular Lens In Vivo
Background/Objectives: To analyze the agreement between two swept-source optical coherence tomography (SS-OCT) devices in assessing glistening on intraocular lenses (IOL). Methods: Patients who had previously undergone cataract surgery were included. They were sequentially examined using two SS-OCT devices: Anterion (Heidelberg Engineering Inc., Heidelberg, Germany) and Triton (Topcon, Inc., Tokyo, Japan). Six corresponding scans from both devices were compared, and glistening, observed as hyperreflective foci (HRF), was manually counted. The total number of HRF and the degree of glistening were measured and categorized into four groups. The agreement between the two devices was analyzed using the intraclass correlation coefficient (ICC). Results: A total of 333 eyes from 285 patients were evaluated. The mean age was 76.5 ± 8.0 years (range: 45–95). The median number of HRF detected in a single scan was 1.1 (IQR 0.0–10.2, range 0–176) using Triton and 2.7 (IQR 0.2–20.1, range 0–250) using Anterion. The ICC across different scans ranged from 0.8 to 0.9, indicating strong agreement between the two devices. Bland–Altman plots showed better concordance in lenses with low glistening grades, while higher grades revealed greater discrepancies, with Anterion detecting significantly more HRF than Triton. Among all factors studied, only postsurgical time was associated with glistening. Conclusions: Two different SS-OCT devices can detect and quantify glistening in IOLs. The concordance between them was high, particularly for lower glistening grades. However, in higher grades, Anterion detected significantly more HRF than Triton.
- 16 January 2026
- Published by Elsevier in Journal Français d'Ophtalmologie
- Vol. 49 (2) , 104773
Iridocorneal angle changes after implantable collamer lens (ICL) implantation: A 10-year follow-up study
- 16 January 2026
- Published by Elsevier in Journal Français d'Ophtalmologie
- Vol. 49 (2) , 104773
Iridocorneal angle changes after implantable collamer lens (ICL) implantation: A 10-year follow-up study
- Open Access
- 19 September 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (18) , 2385
Clinical Applications of Anterior Segment Optical Coherence Tomography in Managing Phakic and Secondary Intraocular Lens Implants: A Comprehensive Review
Anterior segment optical coherence tomography (AS-OCT) has emerged as a crucial imaging technique in ophthalmology, particularly for evaluating intraocular structures and the behavior of phakic and secondary intraocular lenses (IOLs). This narrative review summarizes the latest findings and clinical applications of OCT regarding phakic and secondary IOLs, focusing on their effectiveness, safety, and factors influencing performance. Through a comprehensive analysis of current literature, we explore how OCT facilitates the assessment of IOLs on key anatomical parameters—such as vault, angle configuration, lens centration, tilt, and haptic positioning—essential for optimizing surgical outcomes and minimizing postoperative complications. In phakic IOLs, including posterior chamber lenses such as the Implantable Collamer Lens (ICL, STAAR Surgical, Monrovia, CA, USA) and iris-fixated lenses, such as Artiflex (Ophtec BV, Groningen, The Netherlands), OCT enables precise evaluation of the anterior segment, aiding both candidate selection and long-term monitoring. In secondary implants for aphakia—especially iris-fixated lenses like Artisan (Ophtec BV, Groningen, The Netherlands) and sutureless scleral-fixated lenses such as the Carlevale IOL (Soleko, Rome, Italy)—or those implanted via the Yamane technique, OCT provides high-resolution visualization of haptic fixation, IOL stability, and potential complications, including tilt or decentration. This review also highlights comparative insights between fixation techniques, underscores the need for standardized OCT protocols, and discusses the integration of artificial intelligence tools. In summary, the routine use of OCT in the preoperative and postoperative management of phakic and secondary IOLs has been increasingly incorporated into clinical practice, as it enhances clinical decision-making and improves patient outcomes.
- 19 September 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (18) , 2385
Open AccessClinical Applications of Anterior Segment Optical Coherence Tomography in Managing Phakic and Secondary Intraocular Lens Implants: A Comprehensive Review
Anterior segment optical coherence tomography (AS-OCT) has emerged as a crucial imaging technique in ophthalmology, particularly for evaluating intraocular structures and the behavior of phakic and secondary intraocular lenses (IOLs). This narrative review summarizes the latest findings and clinical applications of OCT regarding phakic and secondary IOLs, focusing on their effectiveness, safety, and factors influencing performance. Through a comprehensive analysis of current literature, we explore how OCT facilitates the assessment of IOLs on key anatomical parameters—such as vault, angle configuration, lens centration, tilt, and haptic positioning—essential for optimizing surgical outcomes and minimizing postoperative complications. In phakic IOLs, including posterior chamber lenses such as the Implantable Collamer Lens (ICL, STAAR Surgical, Monrovia, CA, USA) and iris-fixated lenses, such as Artiflex (Ophtec BV, Groningen, The Netherlands), OCT enables precise evaluation of the anterior segment, aiding both candidate selection and long-term monitoring. In secondary implants for aphakia—especially iris-fixated lenses like Artisan (Ophtec BV, Groningen, The Netherlands) and sutureless scleral-fixated lenses such as the Carlevale IOL (Soleko, Rome, Italy)—or those implanted via the Yamane technique, OCT provides high-resolution visualization of haptic fixation, IOL stability, and potential complications, including tilt or decentration. This review also highlights comparative insights between fixation techniques, underscores the need for standardized OCT protocols, and discusses the integration of artificial intelligence tools. In summary, the routine use of OCT in the preoperative and postoperative management of phakic and secondary IOLs has been increasingly incorporated into clinical practice, as it enhances clinical decision-making and improves patient outcomes.
- Open Access
- 25 November 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (23) , 7125
Influence of Biometric and Corneal Tomographic Parameters on Normative Corneal Aberrations Measured by Root Mean Square
Background/Objectives: To determine the impact of corneal and biometry parameters on the normative root mean square (RMS) values of corneal aberrations measured at a 6 mm diameter. Methods: The RMS values for corneal aberrations (anterior, posterior, and total) were measured along with corneal parameters using Scheimpflug tomography on 770 normal subjects. The biometric parameters were measured with an optical biometer. A multiple linear regression model was used to assess the effect of these parameters on the RMS values for corneal aberrations. Results: The mean RMS values for low-order (LOAs) and high-order 6 mm aberrations (HOAs) were 1.883 ± 0.797 µm and 0.484 ± 0.173 µm, respectively, and for the anterior and posterior cornea, the values were 0.775 ± 0.166 µm and 0.189 ± 0.036 µm, respectively. For the anterior cornea, the main predictors of the RMS LOAs (R2 = 69.8%) were anterior corneal astigmatism (ACA) and anterior corneal elevation (Ele F) on the apex (both p < 0.0001) and for the RMS HOAs (R2 = 33.3%) the main predictors were age, ACA, and Ele F on the thinnest point (all p < 0.0001). For the posterior cornea, considering only the posterior corneal variables, the main predictors of the RMS LOAs (R2 = 63.4%) were posterior corneal astigmatism and posterior corneal elevation (Ele B) on the thinnest point and apex (all p < 0.0001) and for the RMS HOAs (R2 = 46%) the main predictors were the mean posterior keratometry and Ele B on the thinnest point and apex (all p < 0.0001). Conclusions: Normative data of RMS values for corneal aberrations measured over 6 mm are influenced by age and several corneal parameters, which should be considered when evaluating the diagnostic ability of the RMS values.
- 25 November 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (23) , 7125
Open AccessInfluence of Biometric and Corneal Tomographic Parameters on Normative Corneal Aberrations Measured by Root Mean Square
Background/Objectives: To determine the impact of corneal and biometry parameters on the normative root mean square (RMS) values of corneal aberrations measured at a 6 mm diameter. Methods: The RMS values for corneal aberrations (anterior, posterior, and total) were measured along with corneal parameters using Scheimpflug tomography on 770 normal subjects. The biometric parameters were measured with an optical biometer. A multiple linear regression model was used to assess the effect of these parameters on the RMS values for corneal aberrations. Results: The mean RMS values for low-order (LOAs) and high-order 6 mm aberrations (HOAs) were 1.883 ± 0.797 µm and 0.484 ± 0.173 µm, respectively, and for the anterior and posterior cornea, the values were 0.775 ± 0.166 µm and 0.189 ± 0.036 µm, respectively. For the anterior cornea, the main predictors of the RMS LOAs (R2 = 69.8%) were anterior corneal astigmatism (ACA) and anterior corneal elevation (Ele F) on the apex (both p < 0.0001) and for the RMS HOAs (R2 = 33.3%) the main predictors were age, ACA, and Ele F on the thinnest point (all p < 0.0001). For the posterior cornea, considering only the posterior corneal variables, the main predictors of the RMS LOAs (R2 = 63.4%) were posterior corneal astigmatism and posterior corneal elevation (Ele B) on the thinnest point and apex (all p < 0.0001) and for the RMS HOAs (R2 = 46%) the main predictors were the mean posterior keratometry and Ele B on the thinnest point and apex (all p < 0.0001). Conclusions: Normative data of RMS values for corneal aberrations measured over 6 mm are influenced by age and several corneal parameters, which should be considered when evaluating the diagnostic ability of the RMS values.
- Open Access
- 22 November 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (23) , 7070
The Clinical Usefulness of Evaluating the Lens and Intraocular Lenses Using Optical Coherence Tomography: An Updated Literature Review
The Lens Dysfunction Syndrome includes two widespread ocular disorders: presbyopia and cataract. Understanding its etiology, onset, progression, impact, prevention, and treatment remains a significant scientific challenge. The lens is a fundamental structure of the ocular dioptric system that allows for focus adjustment or accommodation to view objects at different distances. Its opacification, primarily related to aging, leads to the development of cataracts. Traditionally, lens alterations have been diagnosed using a slit lamp and later with devices based on the Scheimpflug camera. However, both methods have significant limitations. In recent years, optical coherence tomography (OCT) has become a valuable tool for assessing the lens and pseudophakic intraocular lenses (IOLs) in clinical practice, providing a highly detailed non-invasive evaluation of these structures. Its clinical utility has been described in assessing the shape, location or position, and size of the lens, as well as in determining the degree and type of cataract and its various components. Regarding pseudophakic IOLs, OCT allows for the accurate assessment of their position and centering, as well as for detecting possible complications, including the presence of glistening or IOL opacification. Furthermore, OCT enables the evaluation of the posterior capsule and its associated pathologies, including late capsular distension syndrome. This review highlights the key applications of OCT in the assessment of the lens and pseudophakic IOLs.
- 22 November 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (23) , 7070
Open AccessThe Clinical Usefulness of Evaluating the Lens and Intraocular Lenses Using Optical Coherence Tomography: An Updated Literature Review
The Lens Dysfunction Syndrome includes two widespread ocular disorders: presbyopia and cataract. Understanding its etiology, onset, progression, impact, prevention, and treatment remains a significant scientific challenge. The lens is a fundamental structure of the ocular dioptric system that allows for focus adjustment or accommodation to view objects at different distances. Its opacification, primarily related to aging, leads to the development of cataracts. Traditionally, lens alterations have been diagnosed using a slit lamp and later with devices based on the Scheimpflug camera. However, both methods have significant limitations. In recent years, optical coherence tomography (OCT) has become a valuable tool for assessing the lens and pseudophakic intraocular lenses (IOLs) in clinical practice, providing a highly detailed non-invasive evaluation of these structures. Its clinical utility has been described in assessing the shape, location or position, and size of the lens, as well as in determining the degree and type of cataract and its various components. Regarding pseudophakic IOLs, OCT allows for the accurate assessment of their position and centering, as well as for detecting possible complications, including the presence of glistening or IOL opacification. Furthermore, OCT enables the evaluation of the posterior capsule and its associated pathologies, including late capsular distension syndrome. This review highlights the key applications of OCT in the assessment of the lens and pseudophakic IOLs.
- Open Access
- 26 May 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (11) , 3686
Reply to Stanojcic et al. Comment on “Fernández-Vigo et al. Objective Classification of Glistening in Implanted Intraocular Lenses Using Optical Coherence Tomography: Proposal for a New Classification and Grading System. J. Clin. Med. 2023, 12, 2351”
We appreciate the comments made by Stanojcic et al.
- 26 May 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (11) , 3686
Open AccessReply to Stanojcic et al. Comment on “Fernández-Vigo et al. Objective Classification of Glistening in Implanted Intraocular Lenses Using Optical Coherence Tomography: Proposal for a New Classification and Grading System. J. Clin. Med. 2023, 12, 2351”
We appreciate the comments made by Stanojcic et al.
- Open Access
- 25 May 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (11) , 3664
Normative Topographic Anterior and Posterior Corneal Astigmatism: Axis Distribution and Its Relations with Ocular and Biometric Parameters
Corneal astigmatism correction is a key factor when planning refractive treatment for ametropies with intraocular lenses. We aim to obtain normative anterior and posterior corneal astigmatism (ACA and PCA, respectively) data in a local population and to describe their axis distribution and their association with other parameters. A total of 795 patients with no ocular diseases were evaluated with corneal tomography and optical biometry. Only data of the right eye were included. Mean ACA and PCA were 1.01 ± 0.79 and 0.34 ± 0.17 D, respectively. Vertical steep axis distribution was 73.5% for ACA and 93.3% for PCA. Axis orientation between ACA and PCA matched best for vertical orientation (especially 90° to 120°). Vertical ACA orientation frequency decreased with age, with a more positive sphere and less ACA. Vertical PCA orientation frequency increased with higher PCA. Eyes with vertical ACA orientation were younger and showed a greater white-to-white (WTW) measurement, anterior corneal elevations, ACA and PCA. Eyes with vertical PCA orientation were younger and showed greater anterior corneal elevations and PCA. Normative ACA and PCA data in a Spanish population were presented. Steep axis orientations presented differences with age, WTW, anterior corneal elevations and astigmatism.
- 25 May 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (11) , 3664
Open AccessNormative Topographic Anterior and Posterior Corneal Astigmatism: Axis Distribution and Its Relations with Ocular and Biometric Parameters
Corneal astigmatism correction is a key factor when planning refractive treatment for ametropies with intraocular lenses. We aim to obtain normative anterior and posterior corneal astigmatism (ACA and PCA, respectively) data in a local population and to describe their axis distribution and their association with other parameters. A total of 795 patients with no ocular diseases were evaluated with corneal tomography and optical biometry. Only data of the right eye were included. Mean ACA and PCA were 1.01 ± 0.79 and 0.34 ± 0.17 D, respectively. Vertical steep axis distribution was 73.5% for ACA and 93.3% for PCA. Axis orientation between ACA and PCA matched best for vertical orientation (especially 90° to 120°). Vertical ACA orientation frequency decreased with age, with a more positive sphere and less ACA. Vertical PCA orientation frequency increased with higher PCA. Eyes with vertical ACA orientation were younger and showed a greater white-to-white (WTW) measurement, anterior corneal elevations, ACA and PCA. Eyes with vertical PCA orientation were younger and showed greater anterior corneal elevations and PCA. Normative ACA and PCA data in a Spanish population were presented. Steep axis orientations presented differences with age, WTW, anterior corneal elevations and astigmatism.
- Open Access
- 17 March 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (6) , 2351
Objective Classification of Glistening in Implanted Intraocular Lenses Using Optical Coherence Tomography: Proposal for a New Classification and Grading System
Purpose: To propose a classification of the glistening in intraocular lenses (IOL) using swept-source optical coherence tomography (SS-OCT) by means of a simple, objective and reproducible method that allows the quantification of the presence and severity of glistening. Methods: A cross-sectional study on a sample of 150 eyes of 150 patients who underwent cataract surgery in at least 600 days before the exam and attended a routine examination. Each subject was examined by SS-OCT after pupil dilation, identifying the presence of glistening or hyperreflective foci (HRF) in the central area of the IOL. The degree of glistening was classified into four categories: 0: ≤5 HRF; 1: 6 to 15 HRF; 2: 16 to 30 HRF; and 3: >30 HRF. The intra and interobserver reproducibility (intraclass correlation coefficient, ICC) in the quantification and classification of the glistening were calculated. The correlation between the horizontal and vertical scan of the IOL was also assessed. Results: Glistening was present in the IOL in 42.7% of the patients. The mean number of HRF or glistening microvacuoles was 10.4 ± 26.2 (range 0 to 239). In total, 63.3% of the IOLs had a grade 0, 20% grade a 1, 6.7% grade a 2 and 10% a grade 3. The intraobserver and interobserver reproducibility were very high, both for the absolute quantification of the glistening (ICC ≥ 0.994) and for the severity scale (ICC ≥ 0.967). There was an excellent correlation in the quantification of the IOL glistening between the horizontal and vertical scans (R ≥ 0.834; p < 0.001). Conclusions: The use of SS-OCT makes it possible to identify, quantify and classify IOL glistening in a simple, objective and reproducible way. This technique could provide relevant information for the study of the glistening on IOLs.
- 17 March 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (6) , 2351
Open AccessObjective Classification of Glistening in Implanted Intraocular Lenses Using Optical Coherence Tomography: Proposal for a New Classification and Grading System
Purpose: To propose a classification of the glistening in intraocular lenses (IOL) using swept-source optical coherence tomography (SS-OCT) by means of a simple, objective and reproducible method that allows the quantification of the presence and severity of glistening. Methods: A cross-sectional study on a sample of 150 eyes of 150 patients who underwent cataract surgery in at least 600 days before the exam and attended a routine examination. Each subject was examined by SS-OCT after pupil dilation, identifying the presence of glistening or hyperreflective foci (HRF) in the central area of the IOL. The degree of glistening was classified into four categories: 0: ≤5 HRF; 1: 6 to 15 HRF; 2: 16 to 30 HRF; and 3: >30 HRF. The intra and interobserver reproducibility (intraclass correlation coefficient, ICC) in the quantification and classification of the glistening were calculated. The correlation between the horizontal and vertical scan of the IOL was also assessed. Results: Glistening was present in the IOL in 42.7% of the patients. The mean number of HRF or glistening microvacuoles was 10.4 ± 26.2 (range 0 to 239). In total, 63.3% of the IOLs had a grade 0, 20% grade a 1, 6.7% grade a 2 and 10% a grade 3. The intraobserver and interobserver reproducibility were very high, both for the absolute quantification of the glistening (ICC ≥ 0.994) and for the severity scale (ICC ≥ 0.967). There was an excellent correlation in the quantification of the IOL glistening between the horizontal and vertical scans (R ≥ 0.834; p < 0.001). Conclusions: The use of SS-OCT makes it possible to identify, quantify and classify IOL glistening in a simple, objective and reproducible way. This technique could provide relevant information for the study of the glistening on IOLs.