Xiaoyu Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xiaoyu Li has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Mingyang Hou
School of Microelectronics and Communication Engineering, Chongqing University, Chongqing, 400044, China
8 shared publications - Zhi Yu
School of Microelectronics and Communication Engineering, Chongqing University, Chongqing, China
8 shared publications - Zhiyong Huang
School of Microelectronics and Communication Engineering, Chongqing University, Chongqing, 400044, China; Key Laboratory of Dependable Service Computing in Cyber Physical Society (Chongqing University), Ministry of Education of China, Chongqing University, Chongqing, 400044, China
7 shared publications - Yan Yan
Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
6 shared publications - Yushi Liu
Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, China
6 shared publications - Jiahong Wang
The Second Medical Center, Health Management Institute, National Clinical Research Center for Geriatric Diseases, Chinese PLA General Hospital, Beijing, 100853, China
5 shared publications
Latest Publications
- Open Access
- 4 August 2026
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 14, e83889
Prediction of Blood Transfusion Need and Dose in Patients With Upper Gastrointestinal Bleeding: Retrospective Multicenter Prediction Model Study
Background: Transfusion thresholds in upper gastrointestinal bleeding are debated; hemoglobin cutoffs of 70‐80 g/L are widely cited yet inconsistently applied. Common risk scores offer limited individualized guidance and rarely provide calibrated, interpretable predictions for transfusion decisions. Objective: This study aimed to develop and validate a two-stage, clinically constrained gradient-boosting framework (Medically Constrained Gradient Boosting [MCGB]) that predicts transfusion need and estimates transfusion dose with quantified uncertainty and to implement a prototype recommendation system for clinical use. Methods: We analyzed a retrospective multicenter cohort of 849 adults with endoscopically confirmed upper gastrointestinal bleeding admitted to 3 hospitals in Chongqing, China (January 2019 to August 2025). Predictors available before the transfusion decision included demographics, first recorded vital signs, initial laboratory indices, and clinician-adjudicated etiology. Stage 1 used a calibrated classifier with prespecified monotonic constraints and stability-screened, clinically justified interactions. Stage 2 modeled transfusion dose via quantile predictions with conformal adjustment to generate 95% prediction intervals. Performance was assessed using a cross-site hold-out design. Overall, 2 hospitals were used as the development cohort, within which stratified 5-fold cross-validation was performed for model development, hyperparameter tuning, interaction screening, and calibration. The remaining hospital was held out as an independent test cohort for final evaluation. Hospital-wise alternating external testing was further conducted as a supplementary robustness analysis to assess performance stability across institutions. Classification performance was evaluated using discrimination metrics (area under the receiver operating characteristic curve and area under the precision-recall curve), calibration metrics, and decision-curve analysis; regression performance was evaluated using R ², mean absolute error, and prediction-interval coverage. A graphical user interface was implemented to enable clinicians to input patient data and obtain calibrated predictions of transfusion probability and corresponding dose recommendations. Results: MCGB achieved strong discrimination and good calibration across subgroups (area under the receiver operating characteristic curve=0.97 and area under the precision-recall curve=0.91). At a reference probability threshold of .50, sensitivity, specificity, and F 1 -scores were 0.99, 0.87, and 0.85, respectively, providing a representative operating point for comparison. For dose prediction among transfused patients, MCGB achieved R ² of 0.95 and mean absolute error 0.04; 95% prediction-interval coverage was 0.94, indicating accurate point estimates with reliable uncertainty quantification. The software prototype further demonstrated feasibility of real-time decision support at the bedside. Conclusions: MCGB provides calibrated, interpretable predictions of transfusion need and individualized dose in upper gastrointestinal bleeding and may support bedside decision-making and blood-bank planning, with a prototype interface demonstrating potential for clinical deployment. External validation in additional settings is warranted to confirm generalizability.
- 4 August 2026
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 14, e83889
Open AccessPrediction of Blood Transfusion Need and Dose in Patients With Upper Gastrointestinal Bleeding: Retrospective Multicenter Prediction Model Study
Background: Transfusion thresholds in upper gastrointestinal bleeding are debated; hemoglobin cutoffs of 70‐80 g/L are widely cited yet inconsistently applied. Common risk scores offer limited individualized guidance and rarely provide calibrated, interpretable predictions for transfusion decisions. Objective: This study aimed to develop and validate a two-stage, clinically constrained gradient-boosting framework (Medically Constrained Gradient Boosting [MCGB]) that predicts transfusion need and estimates transfusion dose with quantified uncertainty and to implement a prototype recommendation system for clinical use. Methods: We analyzed a retrospective multicenter cohort of 849 adults with endoscopically confirmed upper gastrointestinal bleeding admitted to 3 hospitals in Chongqing, China (January 2019 to August 2025). Predictors available before the transfusion decision included demographics, first recorded vital signs, initial laboratory indices, and clinician-adjudicated etiology. Stage 1 used a calibrated classifier with prespecified monotonic constraints and stability-screened, clinically justified interactions. Stage 2 modeled transfusion dose via quantile predictions with conformal adjustment to generate 95% prediction intervals. Performance was assessed using a cross-site hold-out design. Overall, 2 hospitals were used as the development cohort, within which stratified 5-fold cross-validation was performed for model development, hyperparameter tuning, interaction screening, and calibration. The remaining hospital was held out as an independent test cohort for final evaluation. Hospital-wise alternating external testing was further conducted as a supplementary robustness analysis to assess performance stability across institutions. Classification performance was evaluated using discrimination metrics (area under the receiver operating characteristic curve and area under the precision-recall curve), calibration metrics, and decision-curve analysis; regression performance was evaluated using R ², mean absolute error, and prediction-interval coverage. A graphical user interface was implemented to enable clinicians to input patient data and obtain calibrated predictions of transfusion probability and corresponding dose recommendations. Results: MCGB achieved strong discrimination and good calibration across subgroups (area under the receiver operating characteristic curve=0.97 and area under the precision-recall curve=0.91). At a reference probability threshold of .50, sensitivity, specificity, and F 1 -scores were 0.99, 0.87, and 0.85, respectively, providing a representative operating point for comparison. For dose prediction among transfused patients, MCGB achieved R ² of 0.95 and mean absolute error 0.04; 95% prediction-interval coverage was 0.94, indicating accurate point estimates with reliable uncertainty quantification. The software prototype further demonstrated feasibility of real-time decision support at the bedside. Conclusions: MCGB provides calibrated, interpretable predictions of transfusion need and individualized dose in upper gastrointestinal bleeding and may support bedside decision-making and blood-bank planning, with a prototype interface demonstrating potential for clinical deployment. External validation in additional settings is warranted to confirm generalizability.
- 11 March 2026
- Published by Elsevier in Medical Image Analysis
- Vol. 111, 104037
Eliminating domain-related confounding factors in cross-domain one-shot medical image segmentation via causal inference
- 11 March 2026
- Published by Elsevier in Medical Image Analysis
- Vol. 111, 104037
Eliminating domain-related confounding factors in cross-domain one-shot medical image segmentation via causal inference
- 21 February 2026
- Published by Elsevier in Pattern Recognition
- Vol. 177
Enhancing Radiography-Report foundation model via Multi-View masked contrastive learning
- 21 February 2026
- Published by Elsevier in Pattern Recognition
- Vol. 177
Enhancing Radiography-Report foundation model via Multi-View masked contrastive learning
- 26 December 2025
- Published by Elsevier in Knowledge-Based Systems
- Vol. 335
BACFormer: A robust boundary-aware transformer for medical image segmentation
- 26 December 2025
- Published by Elsevier in Knowledge-Based Systems
- Vol. 335
BACFormer: A robust boundary-aware transformer for medical image segmentation
- 13 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems for Video Technology
- Vol. 36 (4) , 5301-5314
Overcoming Limitations in One-Shot Semantic Segmentation via Adaptive Visual-Text Guided Prototype Relationship Optimization
The scarcity of high-quality annotated data in medical imaging significantly constrains the performance of deep learning-based segmentation models. While few-shot medical image segmentation (FSMIS) has emerged as a promising solution, existing methods exhibit critical limitations when handling scenarios with inter-class similarity between foreground-background regions and intra-class heterogeneity within foreground objects. Current prototype-based approaches focus primarily on the holistic extraction of the prototype from support images, failing to distinguish subtle anatomical variations and complex feature representations effectively. The AVT-ProNet features three innovative components: 1) An Adaptive Visual-Text Prototype Generation (AVPG) module leveraging CLIP’s cross-modal guide capabilities through adaptive prompting strategies; 2) a graph-based multiregion prototyping relationship optimization (GMPRO) module establishing structural relationships between decomposed subregion prototypes via graph neural networks; 3) a foreground-background prototyping contrast learning (FBPCL) strategy implementing dual-space optimization through inter-class separation and intra-class compactness. The synergistic integration of multi-modal guidance, structural relationship modeling, and contrastive prototype refinement enables our framework to overcome existing limitations in FSMIS. Comprehensive evaluations across multiple clinical scenarios (CHAOS, SABS, and CMR datasets under diverse training configurations) demonstrate superior performance over state-of-the-art approaches, including PANet, CAT-Net, DMAP, and recent PAMI baselines, Source code is available at https://github.com/394481125/AVT-ProNet.
- 13 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems for Video Technology
- Vol. 36 (4) , 5301-5314
Overcoming Limitations in One-Shot Semantic Segmentation via Adaptive Visual-Text Guided Prototype Relationship Optimization
The scarcity of high-quality annotated data in medical imaging significantly constrains the performance of deep learning-based segmentation models. While few-shot medical image segmentation (FSMIS) has emerged as a promising solution, existing methods exhibit critical limitations when handling scenarios with inter-class similarity between foreground-background regions and intra-class heterogeneity within foreground objects. Current prototype-based approaches focus primarily on the holistic extraction of the prototype from support images, failing to distinguish subtle anatomical variations and complex feature representations effectively. The AVT-ProNet features three innovative components: 1) An Adaptive Visual-Text Prototype Generation (AVPG) module leveraging CLIP’s cross-modal guide capabilities through adaptive prompting strategies; 2) a graph-based multiregion prototyping relationship optimization (GMPRO) module establishing structural relationships between decomposed subregion prototypes via graph neural networks; 3) a foreground-background prototyping contrast learning (FBPCL) strategy implementing dual-space optimization through inter-class separation and intra-class compactness. The synergistic integration of multi-modal guidance, structural relationship modeling, and contrastive prototype refinement enables our framework to overcome existing limitations in FSMIS. Comprehensive evaluations across multiple clinical scenarios (CHAOS, SABS, and CMR datasets under diverse training configurations) demonstrate superior performance over state-of-the-art approaches, including PANet, CAT-Net, DMAP, and recent PAMI baselines, Source code is available at https://github.com/394481125/AVT-ProNet.
- 11 September 2025
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 272, 109026
Adaptive gas supply system for membrane oxygenator using online model identification and control in normothermic machine perfusion
- 11 September 2025
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 272, 109026
Adaptive gas supply system for membrane oxygenator using online model identification and control in normothermic machine perfusion
- Open Access
- 10 September 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Medically-Constrained Gradient Boosting for Predicting Blood Transfusion Need and Dose in Upper Gastrointestinal Bleeding (Preprint)
BACKGROUND Transfusion thresholds in upper gastrointestinal bleeding (UGIB) are debated; hemoglobin cutoffs of 70–80 g/L are widely cited yet inconsistently applied. Common risk scores offer limited individualized guidance and rarely provide calibrated, interpretable predictions for transfusion decisions. OBJECTIVE To develop and validate a two-stage, clinically constrained gradient-boosting framework (Medically-Constrained Gradient Boosting, MGCB) that predicts transfusion need and estimates transfusion dose with quantified uncertainty, and to implement a prototype recommendation system for clinical use. METHODS We analyzed a retrospective multicenter cohort of 849 adults with endoscopically confirmed UGIB admitted to three hospitals in Chongqing, China (January 2019–August 2025). Predictors available before the transfusion decision included demographics, first recorded vital signs, initial laboratory indices, and clinician-adjudicated etiology. Stage 1 used a calibrated classifier with prespecified monotonic constraints and stability-screened, clinically justified interactions. Stage 2 modeled transfusion dose via quantile predictions with conformal adjustment to generate 95% prediction intervals. Performance was assessed using stratified five-fold cross-validation with discrimination (AUROC, AUPRC), calibration metrics and decision-curve analysis; regression performance included R², mean absolute error (MAE), and prediction-interval coverage. A graphical user interface was implemented to allow clinician input of patient data and to return calibrated transfusion probabilities and dose recommendations. RESULTS MGCB achieved strong discrimination and good calibration across subgroups (AUROC 0.97; AUPRC 0.91). At a probability threshold of 0.50, sensitivity, specificity, and F1 score were 0.99, 0.87, and 0.85, respectively. For dose prediction among transfused patients, MGCB achieved R² 0.95 and MAE 0.04; 95% prediction-interval coverage was 0.94, indicating accurate point estimates with reliable uncertainty quantification. The software prototype further demonstrated feasibility of real-time decision support at the bedside. CONCLUSIONS MGCB provides calibrated, interpretable predictions of transfusion need and individualized dose in UGIB and may support bedside decision-making and blood-bank planning, with a prototype interface demonstrating potential for clinical deployment. External validation in additional settings is warranted to confirm generalizability. CLINICALTRIAL Not applicable. This study does not involve a registered clinical trial or systematic review.
- 10 September 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessMedically-Constrained Gradient Boosting for Predicting Blood Transfusion Need and Dose in Upper Gastrointestinal Bleeding (Preprint)
BACKGROUND Transfusion thresholds in upper gastrointestinal bleeding (UGIB) are debated; hemoglobin cutoffs of 70–80 g/L are widely cited yet inconsistently applied. Common risk scores offer limited individualized guidance and rarely provide calibrated, interpretable predictions for transfusion decisions. OBJECTIVE To develop and validate a two-stage, clinically constrained gradient-boosting framework (Medically-Constrained Gradient Boosting, MGCB) that predicts transfusion need and estimates transfusion dose with quantified uncertainty, and to implement a prototype recommendation system for clinical use. METHODS We analyzed a retrospective multicenter cohort of 849 adults with endoscopically confirmed UGIB admitted to three hospitals in Chongqing, China (January 2019–August 2025). Predictors available before the transfusion decision included demographics, first recorded vital signs, initial laboratory indices, and clinician-adjudicated etiology. Stage 1 used a calibrated classifier with prespecified monotonic constraints and stability-screened, clinically justified interactions. Stage 2 modeled transfusion dose via quantile predictions with conformal adjustment to generate 95% prediction intervals. Performance was assessed using stratified five-fold cross-validation with discrimination (AUROC, AUPRC), calibration metrics and decision-curve analysis; regression performance included R², mean absolute error (MAE), and prediction-interval coverage. A graphical user interface was implemented to allow clinician input of patient data and to return calibrated transfusion probabilities and dose recommendations. RESULTS MGCB achieved strong discrimination and good calibration across subgroups (AUROC 0.97; AUPRC 0.91). At a probability threshold of 0.50, sensitivity, specificity, and F1 score were 0.99, 0.87, and 0.85, respectively. For dose prediction among transfused patients, MGCB achieved R² 0.95 and MAE 0.04; 95% prediction-interval coverage was 0.94, indicating accurate point estimates with reliable uncertainty quantification. The software prototype further demonstrated feasibility of real-time decision support at the bedside. CONCLUSIONS MGCB provides calibrated, interpretable predictions of transfusion need and individualized dose in UGIB and may support bedside decision-making and blood-bank planning, with a prototype interface demonstrating potential for clinical deployment. External validation in additional settings is warranted to confirm generalizability. CLINICALTRIAL Not applicable. This study does not involve a registered clinical trial or systematic review.
- 2 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29 (10) , 7312-7325
MSCD-VM-UNet: A Vision Mamba Combining Multi-Scale Global and Local Feature Extraction With Cross-Domain Feature Fusion for Medical Image Segmentation
Accurate segmentation of tissues and lesions is essential for diagnosis and treatment. State Space Models (SSMs) have gained attention for their linear complexity and ability to model long-range dependencies. However, the existing Mamba architecture relies on direct skip connections, which limits its ability to integrate multi-scale and multi-level features and handle boundary details effectively. To address these limitations, we propose the MSCD-VM-UNet architecture, which incorporates three novel modules: the Spatial Group Multi-Scale Attention Module (SGMAM), the Cross-Domain Feature Fusion Module (CDFFM), and the Attention-Based Feature Injection Module (ABFIM). The SGMAM captures multi-scale global and local information and adaptively adjusts feature importance to highlight key regions while suppressing noise. The CDFFM enhances boundary and detail handling by aligning semantic features from both the frequency and spatial domains. The ABFIM utilizes attention mechanisms to adaptively fuse and weigh features from different scales and semantics, promoting feature collaboration and improving the model's robustness in complex tasks. Experiments on multiple datasets show that these modules significantly enhance the accuracy of MSCD-VM-UNet, setting a new benchmark for medical image segmentation. Our code will be made available at https://github.com/StphenWang/MSCD-VM-UNet.
- 2 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29 (10) , 7312-7325
MSCD-VM-UNet: A Vision Mamba Combining Multi-Scale Global and Local Feature Extraction With Cross-Domain Feature Fusion for Medical Image Segmentation
Accurate segmentation of tissues and lesions is essential for diagnosis and treatment. State Space Models (SSMs) have gained attention for their linear complexity and ability to model long-range dependencies. However, the existing Mamba architecture relies on direct skip connections, which limits its ability to integrate multi-scale and multi-level features and handle boundary details effectively. To address these limitations, we propose the MSCD-VM-UNet architecture, which incorporates three novel modules: the Spatial Group Multi-Scale Attention Module (SGMAM), the Cross-Domain Feature Fusion Module (CDFFM), and the Attention-Based Feature Injection Module (ABFIM). The SGMAM captures multi-scale global and local information and adaptively adjusts feature importance to highlight key regions while suppressing noise. The CDFFM enhances boundary and detail handling by aligning semantic features from both the frequency and spatial domains. The ABFIM utilizes attention mechanisms to adaptively fuse and weigh features from different scales and semantics, promoting feature collaboration and improving the model's robustness in complex tasks. Experiments on multiple datasets show that these modules significantly enhance the accuracy of MSCD-VM-UNet, setting a new benchmark for medical image segmentation. Our code will be made available at https://github.com/StphenWang/MSCD-VM-UNet.
- 1 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Geoscience and Remote Sensing
- Vol. 63 (01962892) , 1-14
MCECF: A Multiscale Complementary Enhanced Context Fusion Network for Remote Sensing Change Detection
Remote sensing change detection (RSCD) holds significant research value in remote sensing image processing. In recent years, many researchers have achieved remarkable results in RSCD tasks using methods based on CNNs or Transformers. Considering the limited receptive field of CNN models and the high computational cost of Transformers, many researchers have combined the two approaches, yielding promising results. However, most current RSCD-based models focus solely on change and temporal information, overlooking their complementary relationship. Additionally, some multi-scale feature fusion methods emphasize enhancing individual scales while neglecting the correlations between different scales. To address the above issues, we propose a multi-scale complementary enhanced context fusion network (MCECF). The network first introduces a global-local context aggregation module (GLCAM) to capture global-local context information while extracting multi-level feature maps. Subsequently, a complementary enhancement difference module (CEDM) is employed to complementarily aggregate the captured change and temporal information of bi-temporal remote sensing image features. To fully leverage the correlations between multi-scale features, a progressive decoder comprising a supervised spatial attention (SSA) mechanism and a multi-scale complementary enhanced fusion module (MCEFM) was developed. Moreover, to tackle the disparity between changed and unchanged regions, a dual-branch dynamic attention fusion module (DAFM) was designed to enhance the model’s adaptability to diverse scenarios. We conducted comparative experiments on five RSCD datasets against nine SOTA methods, and the results confirmed the effectiveness of the proposed MCECF in RSCD tasks. Our code will be made available at https://github.com/kakuqikaduo/MCECF.
- 1 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Geoscience and Remote Sensing
- Vol. 63 (01962892) , 1-14
MCECF: A Multiscale Complementary Enhanced Context Fusion Network for Remote Sensing Change Detection
Remote sensing change detection (RSCD) holds significant research value in remote sensing image processing. In recent years, many researchers have achieved remarkable results in RSCD tasks using methods based on CNNs or Transformers. Considering the limited receptive field of CNN models and the high computational cost of Transformers, many researchers have combined the two approaches, yielding promising results. However, most current RSCD-based models focus solely on change and temporal information, overlooking their complementary relationship. Additionally, some multi-scale feature fusion methods emphasize enhancing individual scales while neglecting the correlations between different scales. To address the above issues, we propose a multi-scale complementary enhanced context fusion network (MCECF). The network first introduces a global-local context aggregation module (GLCAM) to capture global-local context information while extracting multi-level feature maps. Subsequently, a complementary enhancement difference module (CEDM) is employed to complementarily aggregate the captured change and temporal information of bi-temporal remote sensing image features. To fully leverage the correlations between multi-scale features, a progressive decoder comprising a supervised spatial attention (SSA) mechanism and a multi-scale complementary enhanced fusion module (MCEFM) was developed. Moreover, to tackle the disparity between changed and unchanged regions, a dual-branch dynamic attention fusion module (DAFM) was designed to enhance the model’s adaptability to diverse scenarios. We conducted comparative experiments on five RSCD datasets against nine SOTA methods, and the results confirmed the effectiveness of the proposed MCECF in RSCD tasks. Our code will be made available at https://github.com/kakuqikaduo/MCECF.
- Open Access
- 1 January 2023
- Published by Wiley in Journal of Sensors
- Vol. 2023 (1)
A Combination of Vision‐ and Sensor‐Based Defect Classifications in Extrusion‐Based Additive Manufacturing
Additive manufacturing, also known as 3D printing, has been facing the problem of inconsistent processing defects and product quality as a transformative technology, thus hindering its wide application in industry and other fields. In this context, machine learning (ML) algorithms are increasingly used for automatic classification of process data to achieve computer‐aided defect detection. Specifically, in this paper, two data‐driven classification prediction models are built by monitoring the sensing signals (temperature and vibration data) and interlayer images during the printing process, using the fused deposition model (FDM) as the base case, and the prediction results of the two machine learning models are fused for prediction. The experimental results show that by fusing the prediction results of the two models, the classification accuracy is significantly higher than the prediction results of a single model. These findings can benefit researchers studying FDM with the goal of producing systems that self‐adjust online for quality assurance.
- 1 January 2023
- Published by Wiley in Journal of Sensors
- Vol. 2023 (1)
Open AccessA Combination of Vision‐ and Sensor‐Based Defect Classifications in Extrusion‐Based Additive Manufacturing
Additive manufacturing, also known as 3D printing, has been facing the problem of inconsistent processing defects and product quality as a transformative technology, thus hindering its wide application in industry and other fields. In this context, machine learning (ML) algorithms are increasingly used for automatic classification of process data to achieve computer‐aided defect detection. Specifically, in this paper, two data‐driven classification prediction models are built by monitoring the sensing signals (temperature and vibration data) and interlayer images during the printing process, using the fused deposition model (FDM) as the base case, and the prediction results of the two machine learning models are fused for prediction. The experimental results show that by fusing the prediction results of the two models, the classification accuracy is significantly higher than the prediction results of a single model. These findings can benefit researchers studying FDM with the goal of producing systems that self‐adjust online for quality assurance.