Reinhold Ludwig
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Reinhold Ludwig has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Ara Nazarian
Musculoskeletal Translational Innovation Initiative, Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
2 shared publications - Johnathan W. Adams
Worcester Polytechnic Institute, Worcester, MA, USA
2 shared publications Louis Chen
Worcester Polytechnic Institute, Worcester, MA, USA
2 shared publications- Peter Serano
Worcester Polytechnic Institute, Worcester, MA, USA
2 shared publications Rostislav Lemdiasov
Insight MRI, Inc., 11 Canterbury Street, Worcester, MA 01610, USA
2 shared publications- Sergey N. Makaroff
Dept. of Electrical & Computer Engineering, Worcester Polytechnic Institute, Worcester, MA, USA
2 shared publications
Latest Publications
- 7 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 7 (2) , 187-192
Reducing Non-Through Body Energy Transfer in Microwave Imaging Systems
On-body antennas for use in microwave imaging (MI) systems can direct energy around the body instead of through the body, thus degrading the overall signal-to-noise ratio (SNR) of the system. This work introduces and quantifies the usage of modern metal-backed RF absorbing foam in conjunction with on-body antennas to dampen energy flowing around the body, using both simulations and experiments. A head imaging system is demonstrated herein but the principle can be applied to any part of the body including the torso or extremities. A computational model was simulated numerically using Ansys HFSS. A physical prototype in the form of a helmet with embedded antennas was built to compare simulations with measured data. Simulations and measurements demonstrate that usage of such metal-backed RF-absorbing foams can significantly reduce around-body coupling from Transmit (Tx) and Receive (Rx) antennas by approximately 10 dB. Thus, the overall SNR of the MI system can be substantially improved using this low-cost and affordable method.
- 7 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 7 (2) , 187-192
Reducing Non-Through Body Energy Transfer in Microwave Imaging Systems
On-body antennas for use in microwave imaging (MI) systems can direct energy around the body instead of through the body, thus degrading the overall signal-to-noise ratio (SNR) of the system. This work introduces and quantifies the usage of modern metal-backed RF absorbing foam in conjunction with on-body antennas to dampen energy flowing around the body, using both simulations and experiments. A head imaging system is demonstrated herein but the principle can be applied to any part of the body including the torso or extremities. A computational model was simulated numerically using Ansys HFSS. A physical prototype in the form of a helmet with embedded antennas was built to compare simulations with measured data. Simulations and measurements demonstrate that usage of such metal-backed RF-absorbing foams can significantly reduce around-body coupling from Transmit (Tx) and Receive (Rx) antennas by approximately 10 dB. Thus, the overall SNR of the MI system can be substantially improved using this low-cost and affordable method.
- 3 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 7 (2) , 182-186
Miniaturized Dual Antiphase Patch Antenna Radiating Into the Human Body at 2.4 GHz
An on-body antenna, comprised of two closely-spaced antiphase patch elements, for microwave imaging may provide enhanced signal penetration into the tissue. By further integrating a 180-degree on-chip power splitter with the dual antiphase patch antenna element, a low-profile miniaturized antenna, integrated into a single 18.5 mm × 10 mm × 1.6 mm circuit board assembly, is designed and evaluated both numerically and experimentally. This is the smallest on-body antenna known to the authors for the given frequency band. This linearly polarized antenna may potentially serve as a building block of a dense antenna array for prospective high-resolution microwave imaging. A 2.4 GHz band was chosen as the design target. The final antenna size was a compromise between the miniaturization, the SNR (Signal-to-Noise Ratio), and the targeted antenna bandwidth (2.3–2.5 GHz). The effect of surface waves (the secondary radiating components) was also factored in the design consideration, while maximizing the detected signals’ SNR.
- 3 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 7 (2) , 182-186
Miniaturized Dual Antiphase Patch Antenna Radiating Into the Human Body at 2.4 GHz
An on-body antenna, comprised of two closely-spaced antiphase patch elements, for microwave imaging may provide enhanced signal penetration into the tissue. By further integrating a 180-degree on-chip power splitter with the dual antiphase patch antenna element, a low-profile miniaturized antenna, integrated into a single 18.5 mm × 10 mm × 1.6 mm circuit board assembly, is designed and evaluated both numerically and experimentally. This is the smallest on-body antenna known to the authors for the given frequency band. This linearly polarized antenna may potentially serve as a building block of a dense antenna array for prospective high-resolution microwave imaging. A 2.4 GHz band was chosen as the design target. The final antenna size was a compromise between the miniaturization, the SNR (Signal-to-Noise Ratio), and the targeted antenna bandwidth (2.3–2.5 GHz). The effect of surface waves (the secondary radiating components) was also factored in the design consideration, while maximizing the detected signals’ SNR.
- 1 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 88-92
Automatic Crack Segmentation in Pavements using a Dilated Encoder-Decoder Network
Structural degradation of pavements has a direct impact on road safety. Due to weather conditions, moisture, and intensive use, pavements tend to crack which requires maintenance and repair. Over the last few years, crack detection has become an active research area with the advances of deep learning techniques. Nowadays, multiples techniques are being explored to automatically detect cracks in images. In this paper, we consider the crack detection problem as a semantic segmentation task where we differentiate between crack and noncrack pixels. To do so, we use an encoder-decoder architecture equipped with a dilated convolution module to better capture the contextual information and preserve the spatial resolution. The evaluation of the proposed architecture demonstrates its effectiveness at detecting cracks in pavements and achieves an mIoU of 81%.
- 1 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 88-92
Automatic Crack Segmentation in Pavements using a Dilated Encoder-Decoder Network
Structural degradation of pavements has a direct impact on road safety. Due to weather conditions, moisture, and intensive use, pavements tend to crack which requires maintenance and repair. Over the last few years, crack detection has become an active research area with the advances of deep learning techniques. Nowadays, multiples techniques are being explored to automatically detect cracks in images. In this paper, we consider the crack detection problem as a semantic segmentation task where we differentiate between crack and noncrack pixels. To do so, we use an encoder-decoder architecture equipped with a dilated convolution module to better capture the contextual information and preserve the spatial resolution. The evaluation of the proposed architecture demonstrates its effectiveness at detecting cracks in pavements and achieves an mIoU of 81%.
- 27 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. PP (00189456) , 1
A Novel Compact Convolutional Neural Network for Real-Time Nondestructive Evaluation of Metallic Surfaces
Due to heightened concerns about quality assurance in industry, the inspection of high volume metallic parts has gained significant attention. In this paper, we present a compact convolution neural network based optical nondestructive inspection scheme for high volume metallic components. Our approach enables us to identify surface flaws as small as two thousandth of an inch, while discriminating them from flaw-like features such as glue-spots, dust, stains and scratches. First, we capture the images of the metallic parts with pixel size of 7000-by-2500 and label the images according to flawed and unflawed regions with the help of human experts. Second, we preprocess these images and form more than 120,000 tiles of size 224 x 224 x 3, which subsequently are fed into our compact convolution neural network. Finally, we train the neural network by fine tuning the hyper-parameters to reduce over-fitting of the data and to obtain maximum accuracy. The quantitative evaluation of this network shows that it can achieve almost 99% precision and recall of over 60,000 test images. The total image acquisition and inference time for one part-under-test is approximately 10 seconds. As a result, this novel compact convolution neural network for optical inspection of surface flaws can outperform visual/manual inspection of high volume metallic parts with very high accuracy and within a reasonable evaluation time
- 27 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. PP (00189456) , 1
A Novel Compact Convolutional Neural Network for Real-Time Nondestructive Evaluation of Metallic Surfaces
Due to heightened concerns about quality assurance in industry, the inspection of high volume metallic parts has gained significant attention. In this paper, we present a compact convolution neural network based optical nondestructive inspection scheme for high volume metallic components. Our approach enables us to identify surface flaws as small as two thousandth of an inch, while discriminating them from flaw-like features such as glue-spots, dust, stains and scratches. First, we capture the images of the metallic parts with pixel size of 7000-by-2500 and label the images according to flawed and unflawed regions with the help of human experts. Second, we preprocess these images and form more than 120,000 tiles of size 224 x 224 x 3, which subsequently are fed into our compact convolution neural network. Finally, we train the neural network by fine tuning the hyper-parameters to reduce over-fitting of the data and to obtain maximum accuracy. The quantitative evaluation of this network shows that it can achieve almost 99% precision and recall of over 60,000 test images. The total image acquisition and inference time for one part-under-test is approximately 10 seconds. As a result, this novel compact convolution neural network for optical inspection of surface flaws can outperform visual/manual inspection of high volume metallic parts with very high accuracy and within a reasonable evaluation time
- Open Access
- 23 February 2011
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 210 (1) , 113-122
Helmholtz-pair transmit coil with integrated receive array for high-resolution MRI of trabecular bone in the distal tibia at 7T
- 23 February 2011
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 210 (1) , 113-122
Open AccessHelmholtz-pair transmit coil with integrated receive array for high-resolution MRI of trabecular bone in the distal tibia at 7T
- 1 September 2005
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 24 (3) , 109-119
An NDE Methodology to Predict Density in Green-State Powder Metallurgy Compacts
- 1 September 2005
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 24 (3) , 109-119
An NDE Methodology to Predict Density in Green-State Powder Metallurgy Compacts
- 11 April 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Antennas and Propagation
- Vol. 53 (4) , 1566-1571
MoM volume Integral equation solution for an isolated metal-dielectric resonator with the edge-based basis functions
The objective of the present study is to show that the method of volume integral used in conjunction with the zeroth-order edge-based basis functions (de Carvalho and de Souza Mendes 1999) gives an accurate and stable solution for a metal-dielectric resonator, when the number of the basis functions remains relatively small. Special attention is paid to the resonator in the form of a thin dielectric layer backed by two metal sheets. The metal surface is described in terms of the Rao-Wilton-Glisson (RWG) basis functions.
- 11 April 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Antennas and Propagation
- Vol. 53 (4) , 1566-1571
MoM volume Integral equation solution for an isolated metal-dielectric resonator with the edge-based basis functions
The objective of the present study is to show that the method of volume integral used in conjunction with the zeroth-order edge-based basis functions (de Carvalho and de Souza Mendes 1999) gives an accurate and stable solution for a metal-dielectric resonator, when the number of the basis functions remains relatively small. Special attention is paid to the resonator in the form of a thin dielectric layer backed by two metal sheets. The metal surface is described in terms of the Rao-Wilton-Glisson (RWG) basis functions.
- 26 January 2004
- Published by Wiley in Concepts in Magnetic Resonance Part B
- Vol. 20B (1) , 17-29
Design and implementation of a uniplanar gradient field coil for magnetic resonance imaging
A new approach to design uniplanar gradient coils for magnetic resonance imaging (MRI) is presented. The theoretical formulation involves a constraint cost function between the desired field in a particular region of interest in space and the current‐carrying coil plane based on Biot‐Savart's integral equation. An appropriate weight function in conjunction with linear approximation functions allows the transformation of the problem formulation into a linear matrix equation in which its iterative solution yields discrete current elements in terms of magnitude and direction within the prescribed coil plane. These current elements can be synthesized into an overall practical wire configuration by suitably adding individual wire loops. Numerical predictions and practical testing for aGygradient coil underscore the success of this approach in terms of achieving a highly linear field while maintaining low parasitic fields. © 2004 Wiley Periodicals, Inc. Concepts Magn Reson Part B (Magn Reson Engineering) 20B: 17–29, 2004
- 26 January 2004
- Published by Wiley in Concepts in Magnetic Resonance Part B
- Vol. 20B (1) , 17-29
Design and implementation of a uniplanar gradient field coil for magnetic resonance imaging
A new approach to design uniplanar gradient coils for magnetic resonance imaging (MRI) is presented. The theoretical formulation involves a constraint cost function between the desired field in a particular region of interest in space and the current‐carrying coil plane based on Biot‐Savart's integral equation. An appropriate weight function in conjunction with linear approximation functions allows the transformation of the problem formulation into a linear matrix equation in which its iterative solution yields discrete current elements in terms of magnitude and direction within the prescribed coil plane. These current elements can be synthesized into an overall practical wire configuration by suitably adding individual wire loops. Numerical predictions and practical testing for aGygradient coil underscore the success of this approach in terms of achieving a highly linear field while maintaining low parasitic fields. © 2004 Wiley Periodicals, Inc. Concepts Magn Reson Part B (Magn Reson Engineering) 20B: 17–29, 2004
- 1 January 2004
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 132 (2) , 125-135
A dual RF resonator system for high-field functional magnetic resonance imaging of small animals
- 1 January 2004
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 132 (2) , 125-135
A dual RF resonator system for high-field functional magnetic resonance imaging of small animals