MBMonika Bjelčić

Monika Bjelčić

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Monika Bjelčić has a total of 74 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Jungfraujoch: 38 GB s −1 real-time serial crystallography – data acquisition and live indexing feedback

    by J. Duan, H.-C. Stadler, J. Nan, Z. Matěj, G. Gotthard, F. Dworkowski, M. Bjelcic, O. Aurelius, A. Mozzanica, S. Grimm, et al.

    Significant growth in the quantity of data presents a critical challenge for macromolecular crystallography at fourth-generation synchrotrons. We introduce an updated version of the Jungfraujoch server, reaching a data throughput of 38 GB s −1 from a 9 Mpixel JUNGFRAU detector (JUNGFRAU 9M) operating at 2 kHz, and improving data analysis capabilities with spot finding and indexing. These capabilities provide real-time information that can inform experimental decisions, including which data to retain on disk. In a serial crystallography demonstration at MicroMAX, we illustrate how live indexing integrates into the data collection workflow and show that its results are consistent with offline analysis. By enabling operation of Jungfraujoch on modern x86 hardware, we are lowering the barrier to adopting the system at sources beyond Swiss Light Source 2.0 and MAX IV.


  • Open Access

    A user-friendly goniometer-compatible fixed-target platform for macromolecular crystallography at synchrotrons

    by Swagatha Ghosh, Analia Banacore, Per Norder, Monica Bjelčić, Arpitha Kabbinale, Padmini Nileshwar, Gabrielle Wehlander, Daniele de Sanctis, Shibom Basu, Julien Orlans, et al.

    Fixed-target platforms provide convenient support for microcrystals during serial X-ray crystallography studies using synchrotron radiation. Here, we describe a simple user-friendly 3D-printed support where the crystals are sandwiched between two layers of thin X-ray-transparent membrane resulting in very low scattering background. The platform is compatible with magnetic mounting onto the standard goniometer of macromolecular crystallography beamlines. Our design utilizes a 96-well frame that facilitates hanging-drop experiments directly on the membrane using conventional crystallization plates, thereby eliminating multiple pipetting and crystal handling steps. Crystals can be enclosed in a sandwich and packed into `cassettes', preventing the risk of the sample drying out during room-temperature transportation to synchrotron sources. The versatility of the platform is demonstrated by five structures solved using different crystallization and data-collection strategies. Lysozyme single-crystal rotational crystallography at room temperature is shown, as well as microcrystal serial data collection under cryogenic conditions. On-chip microcrystallization is illustrated by use of a photosynthetic reaction center as an example. Finally, serial crystallography data collection at room temperature from microcrystals of the membrane protein cytochrome c oxidase crystallized in lipidic cubic phase is presented.


  • Open Access

    A simple goniometer-compatible flow cell for serial synchrotron X-ray crystallography. Corrigendum

    by Swagatha Ghosh, Doris Zorić, Peter Dahl, Monika Bjelčić, Jonatan Johannesson, Emil Sandelin, Per Borjesson, Alexander Björling, Analia Banacore, Petra Edlund, et al.

    Information concerning sample preparation in the article by Ghosh et al. [J. Appl. Cryst. (2023), 56, 449–460] is clarified.

  • Open Access

    Microcrystallization and room-temperature serial crystallography structure of human cytochrome P450 3A4

    by Owens Uwangue, Johan Glerup, Andreas Dunge, Monika Bjelcic, Gabrielle Wehlander, Gisela Brändén


  • Open Access

    Status and perspective of protein crystallography at the first multi-bend achromat based synchrotron MAX IV

    by Ana Gonzalez, Tobias Krojer, Jie Nan, Monika Bjelčić, Swati Aggarwal, Ishkan Gorgisyan, Mirko Milas, Mikel Eguiraun, Cecilia Casadei, Manoop Chenchiliyan, et al.

    The first multi-bend achromat based synchrotron MAX IV operates two protein crystallography beamlines, BioMAX and MicroMAX. BioMAX is designed as a versatile, stable, high-throughput beamline catering for most protein crystallography experiments. MicroMAX is a more ambitious beamline dedicated to serial crystallography including time-resolved experiments. Both beamlines exploit the special characteristics of fourth-generation beamlines provided by the 3 GeV ring of MAX IV. In addition, the fragment-based drug discovery platform, FragMAX, is hosted and, at the FemtoMAX beamline, protein diffraction experiments exploring ultrafast time resolution can be performed. A technical and operational overview of the different beamlines and the platform is given as well as an outlook for protein crystallography embedded in the wider possibilities that MAX IV offers to users in the life sciences.


  • Open Access

    Exploring serial crystallography for drug discovery

    by A. Dunge, C. Phan, O. Uwangue, M. Bjelcic, J. Gunnarsson, G. Wehlander, H. Käck, G. Brändén

    Structure-based drug design is highly dependent on the availability of structures of the protein of interest in complex with lead compounds. Ideally, this information can be used to guide the chemical optimization of a compound into a pharmaceutical drug candidate. A limitation of the main structural method used today – conventional X-ray crystallography – is that it only provides structural information about the protein complex in its frozen state. Serial crystallography is a relatively new approach that offers the possibility to study protein structures at room temperature (RT). Here, we explore the use of serial crystallography to determine the structures of the pharmaceutical target, soluble epoxide hydrolase. We introduce a new method to screen for optimal microcrystallization conditions suitable for use in serial crystallography and present a number of RT ligand-bound structures of our target protein. From a comparison between the RT structural data and previously published cryo-temperature structures, we describe an example of a temperature-dependent difference in the ligand-binding mode and observe that flexible loops are better resolved at RT. Finally, we discuss the current limitations and potential future advances of serial crystallography for use within pharmaceutical drug discovery.


  • Open Access

    Room-temperature serial synchrotron crystallography structure of Spinacia oleracea RuBisCO

    by Monika Bjelčić, Oskar Aurelius, Jie Nan, Richard Neutze, Thomas Ursby

    Ribulose-1,5-bisphosphate carboxylase/oxygenase (RuBisCO) is the enzyme responsible for the first step of carbon dioxide (CO 2 ) fixation in plants, which proceeds via the carboxylation of ribulose 1,5-biphosphate. Because of the enormous importance of this reaction in agriculture and the environment, there is considerable interest in the mechanism of fixation of CO 2 by RuBisCO. Here, a serial synchrotron crystallography structure of spinach RuBisCO is reported at 2.3 Å resolution. This structure is consistent with earlier single-crystal X-ray structures of this enzyme and the results are a good starting point for a further push towards time-resolved serial synchrotron crystallography in order to better understand the mechanism of the reaction.


  • Open Access

    Anaerobic fixed-target serial crystallography using sandwiched silicon nitride membranes

    by Monika Bjelčić, Kajsa G. V. Sigfridsson Clauss, Oskar Aurelius, Mirko Milas, Jie Nan, Thomas Ursby

    In recent years, the emergence of serial crystallography, initially pioneered at X-ray free-electron lasers (XFELs), has sparked a growing interest in collecting macromolecular crystallographic data at room temperature. Various fixed-target serial crystallography techniques have been developed, ranging from commercially available chips to in-house designs implemented at different synchrotron facilities. Nevertheless, there is currently no commercially available chip (known to the authors) specifically designed for the direct handling of oxygen-sensitive samples. This study presents a methodology employing silicon nitride chips arranged in a `sandwich' configuration, enabling reliable room-temperature data collection from oxygen-sensitive samples. The method involves the utilization of a custom-made 3D-printed assembling tool and a MX sample holder. To validate the effectiveness of the proposed method, deoxyhemoglobin and methemoglobin samples were investigated using the BioMAX X-ray macromolecular crystallography beamline, the Balder X-ray absorption spectroscopy beamline and UV–Vis absorption spectroscopy.


  • Open Access

    Kilohertz serial crystallography with the JUNGFRAU detector at a fourth-generation synchrotron source

    by Filip Leonarski, Jie Nan, Zdenek Matej, Quentin Bertrand, Antonia Furrer, Ishkhan Gorgisyan, Monika Bjelčić, Michal Kepa, Hannah Glover, Viktoria Hinger, et al.

    Serial and time-resolved macromolecular crystallography are on the rise. However, beam time at X-ray free-electron lasers is limited and most third-generation synchrotron-based macromolecular crystallography beamlines do not offer the necessary infrastructure yet. Here, a new setup is demonstrated, based on the JUNGFRAU detector and Jungfraujoch data-acquisition system, that enables collection of kilohertz serial crystallography data at fourth-generation synchrotrons. More importantly, it is shown that this setup is capable of collecting multiple-time-point time-resolved protein dynamics at kilohertz rates, allowing the probing of microsecond to second dynamics at synchrotrons in a fraction of the time needed previously. A high-quality complete X-ray dataset was obtained within 1 min from lysozyme microcrystals, and the dynamics of the light-driven sodium-pump membrane protein KR2 with a time resolution of 1 ms could be demonstrated. To make the setup more accessible for researchers, downstream data handling and analysis will be automated to allow on-the-fly spot finding and indexing, as well as data processing.


  • Open Access

    A simple goniometer-compatible flow cell for serial synchrotron X-ray crystallography

    by Swagatha Ghosh, Doris Zorić, Peter Dahl, Monika Bjelčić, Jonatan Johannesson, Emil Sandelin, Per Borjesson, Alexander Björling, Analia Banacore, Petra Edlund, et al.

    Serial femtosecond crystallography was initially developed for room-temperature X-ray diffraction studies of macromolecules at X-ray free electron lasers. When combined with tools that initiate biological reactions within microcrystals, time-resolved serial crystallography allows the study of structural changes that occur during an enzyme catalytic reaction. Serial synchrotron X-ray crystallography (SSX), which extends serial crystallography methods to synchrotron radiation sources, is expanding the scientific community using serial diffraction methods. This report presents a simple flow cell that can be used to deliver microcrystals across an X-ray beam during SSX studies. This device consists of an X-ray transparent glass capillary mounted on a goniometer-compatible 3D-printed support and is connected to a syringe pump via lightweight tubing. This flow cell is easily mounted and aligned, and it is disposable so can be rapidly replaced when blocked. This system was demonstrated by collecting SSX data at MAX IV Laboratory from microcrystals of the integral membrane protein cytochrome c oxidase from Thermus thermophilus, from which an X-ray structure was determined to 2.12 Å resolution. This simple SSX platform may help to lower entry barriers for non-expert users of SSX.