LFLi Fang

Li Fang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Li Fang has a total of 102 co-authors. Here are the top co-authors by number of shared publications:

  • Ting Huang

    Department of Urology The First Affiliated Hospital of Ningbo University Ningbo China

    6 shared publications
  • Baiyang Song

    Department of Urology, The First Affiliated Hospital of Ningbo University, Ningbo, China

    5 shared publications
  • Yue Cheng

    Department of Urology, The First Affiliated Hospital of Ningbo University, Ningbo, People’s Republic of China

    5 shared publications
  • Yue Cheng

    Department of Urology, Ningbo Clinical Research Center for Urological Disease, Zhejiang Engineering Research Center of Innovative technologies and diagnostic and therapeutic equipment for urinary system diseases, The First Affiliated Hospital of Ningbo University, Ningbo, China

    4 shared publications
  • Baiyang Song

    Department of Urology, The First Affiliated Hospital of Ningbo University, Ningbo, China

    3 shared publications
  • Guohai Xie

    Department of Urology, Ningbo Clinical Research Center for Urological Disease, Zhejiang Engineering Research Center of Innovative technologies and diagnostic and therapeutic equipment for urinary system diseases, The First Affiliated Hospital of Ningbo University, Ningbo, China

    3 shared publications

Latest Publications

  • Open Access

    A domain-adaptive deep contrastive network for magnetic resonance imaging-driven bladder cancer classification

    by Junjun Huang, Haixia Hu, Mengdan Sun, Weiting Wu, Keyi Xu, Juan Xu, Xufeng Sun, Dongdong Hu, Dandan Yao, Tianran He, et al.

    Bladder cancer is one of the most prevalent malignancies of the urinary system and is associated with high morbidity and mortality. With advances in medical image analysis, deep learning has shown promise for automated bladder cancer classification using magnetic resonance imaging (MRI). However, clinical deployment remains challenging due to substantial inter-center distributional discrepancies and limited feature discriminability between non-muscle-invasive bladder cancer (NMIBC) and muscle-invasive bladder cancer (MIBC). To address these challenges, we propose a Domain-Adaptive Deep Contrastive Network (DADCNet) for MRI-based bladder cancer classification. The proposed framework jointly incorporates source- and target-domain samples during feature learning to obtain domain-invariant yet discriminative representations, thereby improving cross-center generalization. In addition, a deep contrastive learning strategy is introduced to enhance inter-class separability and intra-class compactness, leading to more robust classification. Experiments conducted on a multi-center bladder cancer MRI dataset demonstrate that DADCNet consistently outperforms existing convolutional neural network- and Transformer-based methods, achieving an accuracy of 0.955, an F1-score of 0.955, and an area under the curve of 0.991.


  • Open Access

    Flexible ureteroscopy with a flexible and navigable suction ureteral access sheath versus mini‐percutaneous nephrolithotomy for 1–2 cm lower pole renal stones: Protocol for an international, multicentre, randomized non‐inferiority trial (FLAME trial)

    by Wei Zhu, Jinghua Zhong, Kefeng Wang, Guangming Yin, Chi‐Ho Leung, Nariman Gadzhiev, Mehmet Ilker Gökce, Jaisukh Kalathia, Vineet Gauhar, Guangyuan Zhang, et al.

    Background: Lower pole renal stones measuring 1–2 cm remain challenging to treat. While mini‐percutaneous nephrolithotomy (mini‐PCNL) provides high stone‐free rates (SFRs), it carries tract‐related morbidity. Flexible ureteroscopy (f‐URS) is less invasive but limited in SFR. The flexible and navigable suction ureteral access sheath (FANS) has shown promise in improving stone evacuation and intrarenal pressure control. We hypothesize that FANS f‐URS is non‐inferior to mini‐PCNL for patients with 1–2 cm lower pole stones in SFR. Study Design: The FLAME trial is an international, multicentre, randomized, non‐inferiority study directly comparing FANS‐f‐URS with mini‐PCNL in this setting. Endpoints: The primary outcome is immediate SFR within 72 hours on low‐dose CT. Secondary outcomes include SFR at 1 month, operative time, postoperative pain, hospital stay, complications (Clavien–Dindo) and quality‐of‐life changes. Patients and Methods: A total of 640 adults with CT‐confirmed 1–2 cm lower pole renal stones will be randomized 1:1 to undergo FANS‐f‐URS or mini‐PCNL across 20 high‐volume urology centres worldwide. Randomization is centralized and stratified by site. Radiologists and statisticians will remain blinded to allocation. Sample size was calculated assuming an 85% SFR for both arms, an 8.5% non‐inferiority margin, 80% power and 15% attrition. Analyses will follow both intention‐to‐treat and per‐protocol principles. Trial registration: ClinicalTrials.gov NCT07159035.


  • Harnessing decellularized amniotic membrane properties for ureteral repair: A fibromodulin-driven approach

    by Baiyang Song, Li Fang, Yiwei Hu, Fang Yang, Zewen Shi, Yuhao Cao, Jiasheng Hu, Xue Yang, Zonghuan Wang, Kailei Xu, et al.


  • Regulation of cell migration through cross-sectional morphology design to facilitate implant-to-ureter regeneration

    by Baiyang Song, Zonghuan Wang, Junjun Huang, Yiwei Hu, Fang Yang, Zewen Shi, Yuhao Cao, Li Fang, Hao Rong, Zejun Yan, et al.

  • Impact of negative-pressure ureteral access sheath on preventing “boiled ureter” during holmium laser lithotripsy

    by Baiyang Song, Haojie Du, Yue Cheng, Guohai Xie, Jiasheng Hu, Chengling Yu, Xiaodong Zheng, Zejun Yan, Li Fang

    Purpose To evaluate the impact of negative-pressure ureteral access sheath (NP-UAS) on thermal effects during holmium laser lithotripsy. Materials and Methods A 3D-printed urinary model was used. A ureteroscope, traditional UAS (T-UAS) or NP-UAS, and a 200 µm hollium laser fiber were introduced into the model’s proximal ureter, with the fiber activated for 90 s. Lithotripsy temperature (LT), irrigation flow rate (IFR), and intrarenal pressure (IRP) were measured during flexible ureteroscopic lithotripsy (fURL) and ureteroscopic lithotripsy (URL) using T-UAS or NP-UAS under varying irrigation pressures (IP) and laser powers. Results During fURL at 10 kPa IP, the maximum LT exceeded 43 °C at laser powers of 20W, 30W, and 50W in the T-UAS group, while the NP-UAS group maintained LT < 43 °C. NP-UAS demonstrated significantly greater efficacy in controlling IFR and IRP compared to T-UAS (62.33 ± 2.35 vs. 24.01 ± 0.55 mL/min and 9.13 ± 0.21 vs. 1530.08 ± 112.43 Pa, respectively; p < 0.0001). At 20 kPa IP, only the T-UAS group exceeded a maximum LT of 43 °C at 50W, whereas the NP-UAS group remained below 43 °C. IFR and IRP measures for NP-UAS and T-UAS were 84.24 ± 1.74 mL/min vs. 46.31 ± 0.37 mL/min and 9.89 ± 0.15 Pa vs. 1646.61 ± 38.19 Pa, respectively (p < 0.0001). During URL, all groups maintained LT < 43 °C. At 10 kPa IP, IFR and IRP for NP-UAS and T-UAS were 78.28 ± 1.01 mL/min vs. 44.99 ± 1.09 mL/min and 4752.40 ± 267.72 Pa vs. 7769.63 ± 608.76 Pa, respectively (p < 0.0001). At 20 kPa IP, NP-UAS showed superior IFR (91.33 ± 4.46 mL/min vs. 78.48 ± 0.96 mL/min, p < 0.0001), with IRP exceeding measurement limits in both groups. Conclusion Increasing IFR reduces LT but elevates IRP. NP-UAS effectively maintains LT below critical levels while keeping IRP safe during both fURL and URL.


  • Open Access

    In-depth exploration and initial clinical practice of the ratio of endoscope-sheath diameter theory: smaller flexible ureteroscope with smaller ureteral access sheath

    by Haowen Gu, Pengfei Qin, Jian Shan, Guohai Xie, Jiasheng Hu, Qiang Li, Ting Huang, Jingyu Shi, Yue Cheng, Zejun Yan, et al.

    To assess the outcomes of combining a 7.5Fr flexible ureteroscope (fURS) with a 10/12F ureteral access sheath (UAS) through a comprehensive in vitro and in vivo evalu-ation. We conducted a comparative analysis, evaluating the impact of a 7.5Fr fURS in contrast to others on in trapelvic pressure (IPP) and perfusion fluid flow rate (PFFR) in vitro. This assessµent involved varying ratios of endoscope−sheath diaµeter (RESDs). Subsequently, we prospectively enrolled 23 patients with renal calculi <2 cm who underwent laser lithotripsy using the coµbination of a 7.5Fr fURS and a 10/12F UAS. The patients’ profiles, including preoperative, operative inforµation and postoperative coµplications, were recorded. In vitro experi-ments revealed that IPP and PFFR remained optimal when the RESDs were ≤ 0.75. Notably, only the 7.5Fr fURS ensured a safe IPP when combined with a 10/12F UAS. In clinical research, the sheath placement success rate was 100%, with an average operation time of 55.0 ± 20.0 min and a lithotripsy time of 150.4 ± 199.0 s. Mild ureteral injury necessitated the retention of a double-J stent in five cases for a month. The hospitalization duration and 24-h pain score averaged 45.6 ± 15.5 h and 4.3 ± 3.5, respectively. The one-month stone-free rate was 91.3%. Regarding stent-related symptoms, the overactive bladder symptom score averaged 1.7 ± 1.5, the international prostate symptom score was 3.3 ± 2.8, and the quality of life was 1.3 ± 1.7. Combining a 7.5Fr fURS with a 10/12Fr UAS is recommended as a secure option for treating renal calculi < 2 cm. Postoperative pain management is a future concern.


  • Optimizing infusion-suction diameter ratio (ISDR) in ureteroscopy: in vitro pressure and flow prediction and management

    by Fengqi Wang, Yanqi Xie, Baiyang Song, Wanzhang Liu, Ting Huang, Zhengyi Wang, Pengfei Qin, Dan Jin, Yingzhi Chen, Li Fang, et al.

    To optimize channel configurations for a flexible ureteroscope incorporating both irrigation and suction channels, in vitro experiments were conducted with the aim of achieving safer and more efficient surgical procedures. Upper urinary tract models with integrated pressure-sensing ports were constructed based on CT urography reconstructions. Functional ureteroscope prototypes with various combinations of infusion and suction channel diameters were developed. Using a controlled constant-pressure irrigation system, intrarenal pressure measurements were obtained from the upper, middle, and lower calyces, as well as the renal pelvis. The effects of varying infusion pressures on irrigation flow rates and intrarenal pressure distribution were assessed. Regression models were subsequently established for renal pelvic pressure (RPP) and irrigation flow rate, allowing for the determination of the optimal channel diameter configuration by integrating model predictions with clinical requirements. At an infusion pressure of 500 cmH2O without active suction, the maximum Infusion-to-Suction Diameter Ratio (ISDR) that maintained RPP below the safety threshold was approximately 0.525, corresponding to an Infusion-to-Suction cross-sectional Area Ratio (ISAR) of about 0.276. Theoretically, the optimal combination of infusion and suction channel diameters that satisfies both pressure and flow criteria is 1.03 mm and 1.93 mm, respectively. These findings demonstrate that the ISDR, infusion channel caliber, and irrigation pressure are critical determinants of RPP and flow rate during ureteroscopic procedures. For ureteroscopes with integrated infusion and suction channels, maintaining an ISDR below 0.525—or an ISAR below 0.276—provides favorable balance between procedural safety and irrigation efficiency.


  • Factors affecting the intraoperative calculi excretion during flexible ureteroscopy lithotripsy: an in vitro analysis

    by Baiyang Song, Yue Cheng, Yunfei Lu, Hao Rong, Ting Huang, Jingyu Shi, Li Fang

    Objective To explore the parameters influencing intraoperative calculi excretion (ICE) during flexible ureteroscopy lithotripsy (fURL) using in vitro simulation experiments. Methods 3D-printed human kidney models were used to simulate the elimination of gravel during fURL. The factors influencing the ICE during fURL were analyzed by comparing the effects of different degrees of hydronephrosis (mild, moderate, and severe), surgical positions (supine and lateral position), ratios of endoscope-sheath diameter (RESD) (0.625, 0.725, and 0.825), gravel sizes (0.50–1.00 mm, 0.25–0.50 mm, and 0.10–0.25 mm), and ureteral access sheaths (UASs) (traditional UAS and negative-pressure UAS) on ICE. Results The impacts of various UAS, RESD, degree of hydronephrosis, surgical positions, and gravel sizes on ICE were all significant (p < 0.05). We found no evidence of multicollinearity for all the independent variables, and the linear regression equation fitted as \(\mathrm{ICE }\,({\mathrm{g}}/{\mathrm{min}}) = 0.102 + 0.083*\mathrm{UAS\,grade }- 0.050*\mathrm{RESD\,grade }- 0.048*\mathrm{hydronephrosis\,grade }+ 0.065*\mathrm{position\,grade }- 0.027*\mathrm{gravel\,size\,grade}\) (R2 = 0.569). Conclusion Employing negative-pressure UAS, smaller RESD, milder hydronephrosis, lateral position, and smaller gravel size contribute to improved ICE during fURL. Among them, the adoption of negative-pressure UAS had the most substantial effects.


  • The optimal ratio of endoscope-sheath diameter with negative-pressure ureteral access sheath: an in vitro research

    by Jingyu Shi, Ting Huang, Baiyang Song, Wanzhang Liu, Yue Cheng, Li Fang

    Purpose To maintain safe intrarenal pelvic pressure (IPP), the combination of flexible ureteroscope (fURS) and traditional ureteral access sheath (T-UAS) should maintain a basic rule that is the ratio of endoscope-sheath diameter (RESD) ≤ 0.75. However, the negative-pressure ureteral access sheath (NP-UAS) may break the rule of negative pressure suction. This study aimed to examine the effect of NP-UAS on IPP and flow rate (FR) with varying RESD. Methods In a 3D-printed renal model, flexible ureteroscopy lithotripsy (fURL) was replicated. Six sizes of fURS paired with 12Fr T-UAS and NP-UAS resulted in six distinct RESDs of 0.63, 0.78, 0.87, 0.89, 0.90, and 0.91. While the irrigation pressure (IRP) was set between 100 and 800 cmH2O and the sucking pressure (SP) was set between 0 and 800 cmH2O, the IPP and FR were measured in each RESD. Results NP-UASs can reduce the IPP and increase the FR at the same RESD compared to T-UASs. The IPP decreased with increasing SP with NP-UAS. When RESD ≤ 0.78, T-UAS and NP-UAS can maintain IPP < 40 cmH2O in most circumstances. When RESD = 0.87, it is challenging for T-UAS to sustain IPP < 40 cmH2O; however, NP-UAS can do so. When RESD ≥ 0.89, it is difficult to maintain an IPP < 40 cmH2O even with NP-UAS. Conclusion NP-UAS can decrease IPP and increase FR compared with T-UAS. To maintain a safe IPP, it is recommended that RESD < 0.85 when utilizing NP-UAS.


  • Open Access

    What is the appropriate gravel size during ureteroscopy lithotripsy? An in vitro evaluation

    by Baiyang Song, Dan Jin, Yue Cheng, Zhengyi Wang, Fengqi Wang, Li Fang

    To propose the suitable diameter of calculus debris produced during flexible ureteroscopy lithotripsy (fURL). A glass tube was used to simulate the stone excretion process during Furl. Different stone diameters (0.50–1.00 mm, 0.25–0.50 mm, and 0.10–0.25 mm) with three sizes of flexible ureteroscopy (fURS) (7.5Fr, 8.7Fr, and 9.9Fr) and ureteral access sheath (UAS) (12/14Fr) with or without negative pressure suction were employed in the experiment. The intraoperative calculi excretion (ICE) was recorded according to the stones discharged from the gap between fURS and UAS. The ICE raised significantly in thinner fURS and UAS due to the smaller Ratio of Endoscope-Sheath Diameter (RESD). The gravel size ≤ 0.25 mm was conducive to drainage with traditional UAS, while using fURS with negative-pressure UAS could significantly improve ICE. The gravel size ≤ 0.5 mm was conducive to expulsion. We clarify that ICE during ureteroscopy relates to RESD and negative pressure suction. The proper size of the stone fragment is critical in ensuring the expulsion during fURL, ≤ 0.25 mm in traditional UAS and ≤ 0.50 mm in negative-pressure UAS, respectively.