Lu Peng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lu Peng has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Bo Wei
Faculty of Environmental, Life, Natural Science and Technology, Okayama University, Okayama, 700-8530, Japan
1 shared publication Christina Nurse
Shire, Lexington, MA
1 shared publicationEmel Aygoren-Pursun
Department for Children and Adolescents, Angioedema Centre, University Hospital Frankfurt, Goethe University, Frankfurt, Germany
1 shared publication- Guancong Liu
Tianjin Key Laboratory of Imaging and Sensing Microelectronic Technology, School of Microelectronics Tianjin University Tianjin China
1 shared publication - Hang Song
Hiroshima University
1 shared publication Inmaculada Martinez-Saguer
HZRM Hämophilie Zentrum Rhein Main GmbH, Mörfelden-Walldorf, Germany
1 shared publication
Latest Publications
- 7 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 71 (9) , 4027-4036
A Fused Learning and Enhancing Method for Accurate and Noninvasive Hydration Status Monitoring With UWB Microwave Based on Phantom
Hydration status is a critical indicator for human health, yet there are relatively few studies on monitoring the hydration status of the human body. Traditional methods for hydration monitoring have shortcomings such as being invasive, time-consuming to detect, and not being real time. Recently, microwave hydration monitoring has attracted research interest widely. This approach is noninvasive and based on the change of dielectric properties of human tissues with different hydration statuses. In this article, a fused learning and enhancing method is proposed to accurately monitor the hydration by using an ultrawideband (UWB) microwave. In the proposed method, an Elman neural network learning model and a joint enhancing method are designed. The joint enhancing algorithm is composed of $k$ -medoids and least squares. To verify the performance of the proposed method, a muscle phantom is developed using bovine serum albumin. By changing the concentration, the phantom can mimic the muscle with different hydration statuses. In the evaluation experiment, the S-parameter and frequency data were measured with UWB microwave. Then, the data were employed for assessing the level of hydration with the proposed method. Experimental results showed that the relative error for estimating the concentration of the muscle phantom is less than 3.3%. These results demonstrated the feasibility of the proposed hydration monitoring method and proved that it is promising for monitoring human hydration status.
- 7 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 71 (9) , 4027-4036
A Fused Learning and Enhancing Method for Accurate and Noninvasive Hydration Status Monitoring With UWB Microwave Based on Phantom
Hydration status is a critical indicator for human health, yet there are relatively few studies on monitoring the hydration status of the human body. Traditional methods for hydration monitoring have shortcomings such as being invasive, time-consuming to detect, and not being real time. Recently, microwave hydration monitoring has attracted research interest widely. This approach is noninvasive and based on the change of dielectric properties of human tissues with different hydration statuses. In this article, a fused learning and enhancing method is proposed to accurately monitor the hydration by using an ultrawideband (UWB) microwave. In the proposed method, an Elman neural network learning model and a joint enhancing method are designed. The joint enhancing algorithm is composed of $k$ -medoids and least squares. To verify the performance of the proposed method, a muscle phantom is developed using bovine serum albumin. By changing the concentration, the phantom can mimic the muscle with different hydration statuses. In the evaluation experiment, the S-parameter and frequency data were measured with UWB microwave. Then, the data were employed for assessing the level of hydration with the proposed method. Experimental results showed that the relative error for estimating the concentration of the muscle phantom is less than 3.3%. These results demonstrated the feasibility of the proposed hydration monitoring method and proved that it is promising for monitoring human hydration status.
- Open Access
- 1 February 2019
- Published by Elsevier in Journal of Allergy and Clinical Immunology
- Vol. 143 (2) , AB43
Efficacy and safety of lanadelumab for prophylactic treatment in adolescents with hereditary angioedema (HAE)
- 1 February 2019
- Published by Elsevier in Journal of Allergy and Clinical Immunology
- Vol. 143 (2) , AB43
Open AccessEfficacy and safety of lanadelumab for prophylactic treatment in adolescents with hereditary angioedema (HAE)