LCLin Chen

Lin Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lin Chen has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Identification and Analysis of Low-Frequency Oscillation in a Multi-Grid-Forming-VSC Grid-Connected System

    by Min Zhang, Rui Fan, Huipeng Li, Jun Zhao, Tengxin Wang, Lin Chen

    The existing low-frequency oscillation analysis method of a multi-grid-forming-VSC (voltage source converter) is greatly affected by modeling accuracy, and its oscillation mode can only be determined by acquiring the control parameters of the system. Therefore, a method of identifying low-frequency oscillation characteristics of multi-VSC based on VMD (variational mode decomposition) and a Prony algorithm was proposed in this paper. The Prony algorithm is sensitive to noise, and its identification accuracy is greatly affected by noise. Thus, the VMD algorithm was utilized to denoise the measured data. Then, the Prony algorithm was applied to analyze the low-frequency oscillation of the measured data of single VSC and multi-VSC grid-connected systems, and its applicability to different grid-forming VSCs was verified. The error comparison results showed that the proposed low-frequency oscillation identification method had high accuracy. Furthermore, the influence of the number of parallel VSCs, grid strength and active output on the low-frequency oscillation of the system was investigated. Finally, the effectiveness of the proposed low-frequency oscillation method was verified by building a physical experimental platform.


  • Open Access

    Harmonic Resonance Analysis and Impedance Remodeling Method of Multi-Inverter Grid-Connected System

    by Min Zhang, Jinhao Wang, Shifeng Zhang, Le Gao, Xiangyu Guo, Lin Chen, Yonghai Xu

    The harmonic and resonant characteristics of a multi-inverter grid-connected system can negatively affect power quality when weak grid conditions are present. In this paper, firstly, harmonic currents are modeled for the inverter, the correctness of low-frequency harmonics and high-frequency harmonics are verified in closed loop, and the characteristics of harmonic currents are analyzed when the parameters are varied. Secondly, the resonant characteristics of the inverter with feed-forward link are analyzed, and a multi-inverter grid-connected equivalent model based on the triple-decomposition conductance is developed and analyzed in conjunction with the resonant modal analysis method. Then, a harmonic resonance impedance reshaping method is proposed to suppress the background harmonics using improved weighted average current control (WACC), suppress the system resonance based on the point of common coupling (PCC) paralleling virtual conductance method, and improve the stability margin of the system combined with impedance reshaping resonance suppression method. Finally, simulations and comparison of results with different suppression methods verify the superiority and effectiveness of the proposed method.


  • Open Access

    Multi-Inverter Resonance Modal Analysis Based on Decomposed Conductance Model

    by Lin Chen, Yonghai Xu, Shun Tao, Tianze Wang, Shuguang Sun

    The Norton equivalent model based on the transfer function and the frequency domain analysis method for inverter resonance analysis lacks a comprehensive analysis of the resonant characteristics, and more information about the resonant key components and the degree of participation cannot be obtained. In this paper, a decomposed conductance model is proposed to characterize the resonance characteristics of the multi-inverter grid-connected system and the effect of the equivalent control link of the inverter on the resonance in more detail by combining the modal analysis method and the sensitivity analysis method. Firstly, based on αβ coordinates, the conductance division is carried out for the dual-loop inverter control link with the voltage external loop and current internal loop using capacitor-current feedback damping, and the inverter model based on the decomposition conductance is derived. The mathematical model of the multi-inverter grid-connected system is then established. Secondly, the resonance characteristics of the system are analyzed by combining the modal and frequency domain analysis methods when the number of inverters, inverter parameters, and grid-side impedance are changed. Thirdly, the degree of involvement of the system components, especially the equivalent control link of the inverter in resonance conditions, is determined in combination with the proposed model and the sensitivity analysis method, which is the basis for proposing an effective suppression strategy. Finally, a simulation model is built to verify the proposed method and the analysis results.