FAFarid Amrinsani

Farid Amrinsani

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Farid Amrinsani has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluating the effectiveness of digital filtering techniques in electronic stethoscopes: a study of Kalman and Butterworth filters

    by Endang Dian Setioningsih, Sumber Sumber, Triwiyanto Triwiyanto, Vugar Abdullayev, Farid Amrinsani, Bima Maulana Raharjo, Tetrik Fa’ALtin

    Heart sound, or phonocardiogram (PCG), signals are often distorted by noise from respiration, movement, and the surrounding environment, which complicates accurate cardiac feature extraction in portable monitoring systems. This study aims to design and evaluate an effective digital filtering method to enhance PCG signal quality obtained from a low-cost acquisition system based on a condenser microphone sensor and an ESP32 microcontroller. The main contribution of this work is the implementation and comparison of two noise-reduction approaches: Butterworth band-pass filters of various orders and the Kalman filter applied to PCG signals acquired from mannequin-based simulations. Data were recorded for 10 seconds at a 1000 Hz sampling rate, processed in MATLAB, and analyzed using the fast Fourier transform (FFT) to determine the optimal frequency ranges. Experimental results demonstrate that the 8th-order Butterworth band-pass filter achieved the highest signal-to-noise ratio (SNR) improvement, averaging 25.659 dB, outperforming other configurations. These findings indicate that an appropriately tuned Butterworth filter provides a simpler yet robust solution for real-time PCG denoising in embedded systems. Future work will integrate the filtering process directly into the ESP32 firmware and evaluate its performance on human subjects to enhance clinical applicability.

  • Open Access

    Comparison of two Wireless Electromyography Sensor Module Designs using wet electrodes and dry electrodes at the time of Sitting motion to stand

    by Farid Amrinsani, Levana Forra Wakidi, Made Dwi Pandya Suryanta, Dessy Tri Wulandari, Wahyu Caesarendra

    One of the biosignals used to identify muscle signals in humans is electromyography. Electromyography signals are frequently utilized as input and are designed to aid in post-stroke therapy recovery or to assist people with disabilities. This phenomena has led to the development of numerous electromyography module sensor designs for use in support of various research-based applications. In this study, an electromyography sensor module without an electrode cable is compared to an electromyography sensor module that uses gel electrodes, plate electrodes, electrode cables, and other electrode technologies. A function generator is used to test each module, and the correlation value is sought to determine the connection between the two modules under consideration. Later, the findings of this study served as the foundation for other studies. Researchers also wish to explore the possibility of developing an electromyography sensor module by altering the wireless EMG sensor module's structure and design. Whereas this study can subsequently be extremely helpful to improve the standing of the Health Poltekkes Kemenkes Surabaya.

  • Open Access

    Detection Signal Electromyograpy using Dry Electrode and Disposible Electrodes on the Upper Extremity when Lifting Weights

    by Farid Amrinsani, Levana Forra Wakidi, Made Dwi Pandya Suryanta, Dessy Tri Wulandari, Muhammad Tariq Sadiq

    One of the biosignals used to identify human muscle impulses is electromyography. Electromyographic signals are frequently utilized as inputs and are designed to help persons with disabilities or aid in the healing process following stroke therapy. According to studies, this occurrence has led to the development of numerous electromyography module sensor designs to meet different purposes. In this work, disposable electrodes and dry electrodes are used to examine the root mean square RMS values of two different electromyography sensor module types. With a 3 kg barber lift action, each module is used to detect signals in the biceps, which are part of the upper extremity muscles. According to the study's findings, the two electromyography modules with disposable electrodes produced data with a p-value of 0.001766368 0.05. It can be inferred that there is no difference between the E1 and E2 modules because the p-value for the t-test of the two modules with dry electrodes is 0.001766368 0.05. However, there is a variance in the amplitude's magnitude, with a difference of 30mV between the disposable and dry electrodes. The results of this study can be used to teach students, and a module developed as a result of it can be applied to other studies to help find electromyographic signals.


  • Optimal Long Distance ECG Signal Data Delivery Using LoRa Technology

    by Priyambada Cahya Nugraha, I Dewa Gede Hari Wisana, Dyah Titisari, Farid Amrinsani

    Cardiovascular disease is the leading cause of death in the world and the number one killer in Indonesia, with a mortality rate of 17.05%. The target of this research is to increase the range of electrocardiograph (ECG) equipment using LoRa Technology. With LoRa Technology, it is expected that the data transmission process can run effectively and produce an accurate ECG signal and minimal noise. The research method is by sending a heart signal from the ECG simulator by the microcontroller via LoRa Technology which is received by the PC (Personal Computer) and the ECG signal is displayed on the PC display. The most optimal setting will be obtained from the sender-receiver distance and baudrate by measuring data loss and delay. In this study, the simulated cardiac signal from the phantom ECG is fed to an analog signal processing circuit, then the signal is converted to digital and digitally filtered on the microcontroller, then the signal is sent via the LoRa HC-12 Transceiver to a PC with baudrate, distance and barrier settings. The results obtained are that data transmission can be carried out at a distance of 175 meters without a barrier and a distance of 50 meters with a barrier. This remote ECG equipment can detect heart signals and the results can be sent to a PC using LoRa Technology. The implication is that the transmission of ECG signal data via the Lora HC-12 Transceiver media can be carried out optimally at the 9600 baudrate setting.


  • The Monitoring of Oxygen Saturation and Heart Rate Using a Telemedicine Smartphone System (TMSS) as a New Innovation in the Health Sector

    by I Dewa Gede Hari Wisana, Priyambada Cahya Nugraha, Mamurotun Mamurotun, Farid Amrinsani

    As a country with the world's sixth-largest population with 11.22% poor population, Indonesia encounters health problems as one of the main issues. According to the Progress Report in Asia & the Pacific, Indonesia is still experiencing delays in the process of achieving the Millennium Development Goals. This study aimed to produce technological innovations related to the monitoring of oxygen saturation and heartbeat using the Telemedicine Smartphone System (TMSS). The contribution of this research is the resulting technological innovations related to the field of telemedicine that can be applied by Indonesian people at affordable prices. The monitoring tools will be effective and efficient when the tools are made with real-time monitoring of SpO2 and BPM using the TMSS system to improve Indonesia's development of health services. This design uses a fingertip sensor to detect oxygen saturation in the blood and an ear clip sensor to detect heartbeats, both sensors have an analog output which is conditioned in the Analog Signal Conditioning (ASC) circuit. The ASC’s output is processed on AT mega 328P. The resulting data is further displayed on the Liquid Character Display (LCD). Data are also sent via HC-05 Bluetooth and displayed on an Android Smartphone with SMS notifications. Based on the measurement results, the greatest error value was 0.220%, while the smallest was 0.055% on the SpO2. BPM had the largest error value of 2.33392%, while the smallest was 0.2283%. This research can be implemented into the transmission system using TMSS to improve the development of health services in Indonesia.