Yuuki Shida
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Yuuki Shida has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Hiroyasu Iwata
Faculty of Science and Engineering, Waseda University, Tokyo, Japan
5 shared publicationsHaruaki Chiba
NSK Ltd Technology Development Department 1New Field Products Development Center Technology Development Division Headquarters, Kanagawa, Japan
2 shared publicationsMasami Sugawara
Graduate School of Creative Science and Engineering, Waseda University, Tokyo, Japan
2 shared publications- Ryosuke Tsumura
Health and Medical Research Institute, National Institute of Advanced Industrial Science and Technology, Tsukuba 305-8564, Japan
2 shared publications Souto Kumagai
Graduate School of Creative Science and Engineering, Waseda University, Tokyo, Japan
2 shared publicationsTokuhisa Uejima
The Cardiovascular Institute, Tokyo, Japan
2 shared publications
Latest Publications
- Open Access
- 6 November 2024
- Published by Cambridge University Press (CUP) in Robotica
- Vol. 43 (1) , 368-386
Development of a seat support mechanism for guiding users to an appropriate posture in a seated-style echocardiography robot
This paper proposes a seat support mechanism to solve the problem of misalignment between the chest examination and probe scanning areas when the patient is bent in a seated-style echocardiography robot. To guide the patient to an appropriate body position where their chest is within the examination range of the chest examination unit while minimizing the physical load of the patient, the posture of the patient must satisfy the three following conditions. (i) The breech must be in contact with the seat surface, (ii) the legs must be vertical to the floor, and (iii) the chest and mechanism must be parallel while the probe scanning and chest examination ranges must match. The human body was modeled to derive a posture that satisfies the aforementioned conditions for the height of each individual, and a seat support mechanism with four degrees of freedom was installed to guide the user to the derived posture. By installing this mechanism, the body load of the left biceps brachii, right biceps brachii, left latissimus dorsi, and right latissimus dorsi was reduced to 64.7%, 52.7%, 86.4%, and 80.2%, respectively. The sharpness of the image contours was improved to 103.8%.
- 6 November 2024
- Published by Cambridge University Press (CUP) in Robotica
- Vol. 43 (1) , 368-386
Open AccessDevelopment of a seat support mechanism for guiding users to an appropriate posture in a seated-style echocardiography robot
This paper proposes a seat support mechanism to solve the problem of misalignment between the chest examination and probe scanning areas when the patient is bent in a seated-style echocardiography robot. To guide the patient to an appropriate body position where their chest is within the examination range of the chest examination unit while minimizing the physical load of the patient, the posture of the patient must satisfy the three following conditions. (i) The breech must be in contact with the seat surface, (ii) the legs must be vertical to the floor, and (iii) the chest and mechanism must be parallel while the probe scanning and chest examination ranges must match. The human body was modeled to derive a posture that satisfies the aforementioned conditions for the height of each individual, and a seat support mechanism with four degrees of freedom was installed to guide the user to the derived posture. By installing this mechanism, the body load of the left biceps brachii, right biceps brachii, left latissimus dorsi, and right latissimus dorsi was reduced to 64.7%, 52.7%, 86.4%, and 80.2%, respectively. The sharpness of the image contours was improved to 103.8%.
- Open Access
- 20 September 2024
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 20 (1) , 191-202
Robotic navigation with deep reinforcement learning in transthoracic echocardiography
Purpose: The search for heart components in robotic transthoracic echocardiography is a time-consuming process. This paper proposes an optimized robotic navigation system for heart components using deep reinforcement learning to achieve an efficient and effective search technique for heart components. Method: The proposed method introduces (i) an optimized search behavior generation algorithm that avoids multiple local solutions and searches for the optimal solution and (ii) an optimized path generation algorithm that minimizes the search path, thereby realizing short search times. Results: The mitral valve search with the proposed method reaches the optimal solution with a probability of 74.4%, the mitral valve confidence loss rate when the local solution stops is 16.3% on average, and the inspection time with the generated path is 48.6 s on average, which is 56.6% of the time cost of the conventional method. Conclusion: The results indicate that the proposed method improves the search efficiency, and the optimal location can be searched in many cases with the proposed method, and the loss rate of the confidence in the mitral valve was low even when a local solution rather than the optimal solution was reached. It is suggested that the proposed method enables accurate and quick robotic navigation to find heart components.
- 20 September 2024
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 20 (1) , 191-202
Open AccessRobotic navigation with deep reinforcement learning in transthoracic echocardiography
Purpose: The search for heart components in robotic transthoracic echocardiography is a time-consuming process. This paper proposes an optimized robotic navigation system for heart components using deep reinforcement learning to achieve an efficient and effective search technique for heart components. Method: The proposed method introduces (i) an optimized search behavior generation algorithm that avoids multiple local solutions and searches for the optimal solution and (ii) an optimized path generation algorithm that minimizes the search path, thereby realizing short search times. Results: The mitral valve search with the proposed method reaches the optimal solution with a probability of 74.4%, the mitral valve confidence loss rate when the local solution stops is 16.3% on average, and the inspection time with the generated path is 48.6 s on average, which is 56.6% of the time cost of the conventional method. Conclusion: The results indicate that the proposed method improves the search efficiency, and the optimal location can be searched in many cases with the proposed method, and the loss rate of the confidence in the mitral valve was low even when a local solution rather than the optimal solution was reached. It is suggested that the proposed method enables accurate and quick robotic navigation to find heart components.
- Open Access
- 5 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 8 (8) , 5228-5235
Automated Image Acquisition of Parasternal Long-Axis View With Robotic Echocardiography
This study proposes a method for finding a parasternal long-axis view in echocardiography autonomously with a robotic ultrasound (US) system. In obtaining this view, it is necessary to avoid the ribs and lungs because they reduce the clarity of US image. Meanwhile, the anatomical position and size of the heart, lungs, and ribs differ between individuals, which makes it difficult to find the optimal position of the US probe. Our proposed system is comprised of the following three processes. First, an exhaustive scan of the chest wall region is performed. The position of the probe that allows the mitral valve to be centrally positioned is estimated based on this scan. Second, the probe is rotated once in the yaw direction while being fixed in that position. The yaw angle is estimated at a point parallel to the left ventricular longitudinal axis in the acquired images. Finally, the pitch angle of the probe is estimated so that the probe avoids the connection between the mitral valve and the papillary muscle and chordae. To validate the proposed method, we performed human trials with five healthy subjects and measured the detection rate of observation points used to evaluate the image quality of parasternal long-axis view. The result showed that the median detection rate of the observation points was 63.3 ± 5.3%, which implies that the proposed method is valid.
- 5 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 8 (8) , 5228-5235
Open AccessAutomated Image Acquisition of Parasternal Long-Axis View With Robotic Echocardiography
This study proposes a method for finding a parasternal long-axis view in echocardiography autonomously with a robotic ultrasound (US) system. In obtaining this view, it is necessary to avoid the ribs and lungs because they reduce the clarity of US image. Meanwhile, the anatomical position and size of the heart, lungs, and ribs differ between individuals, which makes it difficult to find the optimal position of the US probe. Our proposed system is comprised of the following three processes. First, an exhaustive scan of the chest wall region is performed. The position of the probe that allows the mitral valve to be centrally positioned is estimated based on this scan. Second, the probe is rotated once in the yaw direction while being fixed in that position. The yaw angle is estimated at a point parallel to the left ventricular longitudinal axis in the acquired images. Finally, the pitch angle of the probe is estimated so that the probe avoids the connection between the mitral valve and the papillary muscle and chordae. To validate the proposed method, we performed human trials with five healthy subjects and measured the detection rate of observation points used to evaluate the image quality of parasternal long-axis view. The result showed that the median detection rate of the observation points was 63.3 ± 5.3%, which implies that the proposed method is valid.
- Open Access
- 7 March 2023
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 18 (5) , 887-897
Diagnostic posture control system for seated-style echocardiography robot
Purpose: Conventional robotic ultrasound systems were utilized with patients in supine positions. Meanwhile, the limitation of the systems is that it is difficult to evacuate the patients in case of emergency (e.g., patient discomfort and system failure) because the patients are restricted between the robot system and bed. Therefore, we validated a feasibility study of seated-style echocardiography using a robot. Method: Preliminary experiments were conducted to verify the following two points: (1) diagnostic image quality due to the sitting posture angle and (2) physical load due to the sitting posture angle. For reducing the physical burden, two unique mechanisms were incorporated into the system: (1) a leg pendulum base mechanism to reduce the load on the legs when the lateral bending angle increases, and (2) a roll angle division by a lumbar lateral bending and thoracic rotation mechanisms. Results: Preliminary results demonstrated that adjusting the diagnostic posture angle allowed to obtain the views, including cardiac disease features, as in the conventional examination. The results also demonstrated that the body load reduction mechanism incorporated in the results could reduce the physical load in the seated echocardiography. Furthermore, this system was shown to provide greater safety and shorter evacuation times than conventional systems. Conclusion: These results indicate that diagnostic echocardiographic images can be obtained by seated-style echocardiography. It was also suggested that the proposed system can reduce the physical load and guarantee a sense of safety and emergency evacuation. These results demonstrated the possibility of the usage of the seated-style echocardiography robot.
- 7 March 2023
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 18 (5) , 887-897
Open AccessDiagnostic posture control system for seated-style echocardiography robot
Purpose: Conventional robotic ultrasound systems were utilized with patients in supine positions. Meanwhile, the limitation of the systems is that it is difficult to evacuate the patients in case of emergency (e.g., patient discomfort and system failure) because the patients are restricted between the robot system and bed. Therefore, we validated a feasibility study of seated-style echocardiography using a robot. Method: Preliminary experiments were conducted to verify the following two points: (1) diagnostic image quality due to the sitting posture angle and (2) physical load due to the sitting posture angle. For reducing the physical burden, two unique mechanisms were incorporated into the system: (1) a leg pendulum base mechanism to reduce the load on the legs when the lateral bending angle increases, and (2) a roll angle division by a lumbar lateral bending and thoracic rotation mechanisms. Results: Preliminary results demonstrated that adjusting the diagnostic posture angle allowed to obtain the views, including cardiac disease features, as in the conventional examination. The results also demonstrated that the body load reduction mechanism incorporated in the results could reduce the physical load in the seated echocardiography. Furthermore, this system was shown to provide greater safety and shorter evacuation times than conventional systems. Conclusion: These results indicate that diagnostic echocardiographic images can be obtained by seated-style echocardiography. It was also suggested that the proposed system can reduce the physical load and guarantee a sense of safety and emergency evacuation. These results demonstrated the possibility of the usage of the seated-style echocardiography robot.
- Open Access
Diagnostic Posture Control System for Seated-Style Echocardiography Robot
Purpose: Conventional robotic ultrasound systems were utilized with patients in supine positions. Meanwhile, the limitation of the systems is that it is difficult to evacuate the patients in case of emergency (e.g., patient discomfort and system failure) because the patients are restricted between the robot system and bed. Then, it is ideal that the patient undergoes the examination in the sitting position in terms of safety. Therefore, we validated a feasibility study of seated-style echocardiography using a robot. Method: Preliminary experiments were conducted to verify the following two points: (1) the possibility of obtaining cardiac disease features in the sitting posture as well as in the conventional examination, and (2) the relationship between posture angle and physical burden. For reducing the physical burden, two unique mechanisms were incorporated into the system: (1) a leg pendulum base mechanism to reduce the load on the legs when the lateral bending angle increases, and (2) a roll angle division by a lumbar lateral bending and thoracic rotation mechanisms. Results: Preliminary results demonstrated that adjusting the diagnostic posture angle enabled us to obtain the views, including cardiac disease features, as in the conventional examination. The results showed that the body burden increased as the posture's lateral bending angle increased. The results also demonstrated that the body load reduction mechanism incorporated in the results could reduce the physical load in the seated echocardiography. Conclusion: These results showed the potential of the seated-style echocardiography robot.
Open AccessDiagnostic Posture Control System for Seated-Style Echocardiography Robot
Purpose: Conventional robotic ultrasound systems were utilized with patients in supine positions. Meanwhile, the limitation of the systems is that it is difficult to evacuate the patients in case of emergency (e.g., patient discomfort and system failure) because the patients are restricted between the robot system and bed. Then, it is ideal that the patient undergoes the examination in the sitting position in terms of safety. Therefore, we validated a feasibility study of seated-style echocardiography using a robot. Method: Preliminary experiments were conducted to verify the following two points: (1) the possibility of obtaining cardiac disease features in the sitting posture as well as in the conventional examination, and (2) the relationship between posture angle and physical burden. For reducing the physical burden, two unique mechanisms were incorporated into the system: (1) a leg pendulum base mechanism to reduce the load on the legs when the lateral bending angle increases, and (2) a roll angle division by a lumbar lateral bending and thoracic rotation mechanisms. Results: Preliminary results demonstrated that adjusting the diagnostic posture angle enabled us to obtain the views, including cardiac disease features, as in the conventional examination. The results showed that the body burden increased as the posture's lateral bending angle increased. The results also demonstrated that the body load reduction mechanism incorporated in the results could reduce the physical load in the seated echocardiography. Conclusion: These results showed the potential of the seated-style echocardiography robot.