Xingliang Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xingliang Wu has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Guochen Wang
Harbin Institute of Technology
2 shared publications - Zicheng Wang
College of Computer and Control Engineering, Northeast Forestry University, Harbin 150040, China
2 shared publications - Bo Zhao
Harbin Institute of Technology, Harbin 150001, China
1 shared publication Dong-Xue Xi
1 shared publication- Fan Yang
Shaanxi Dongfang Aviation Instrument Co., Ltd., Hanzhong 723000, China
1 shared publication Fu-Gang Wang
1 shared publication
Latest Publications
- 28 October 2026
- Published by Elsevier in Measurement
- Vol. 293
Wide-range triaxial electrostatic accelerometer for non-quiet satellites: Indirect testing and on-orbit validation
- 28 October 2026
- Published by Elsevier in Measurement
- Vol. 293
Wide-range triaxial electrostatic accelerometer for non-quiet satellites: Indirect testing and on-orbit validation
- 26 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (15) , 23918-23928
Sensitivity-Enhanced Temperature Sensor of Cascaded Lyot Filter and Mach–Zehnder Interferometer Based on the Vernier Effect
The compact structure and resistance to electromagnetic interference of optical fiber temperature sensors have garnered significant interest. Nevertheless, it is imperative to enhance the detecting sensitivity in order to adequately fulfill the existing requirements. This study proposes and demonstrates a sensitivity-enhanced optical fiber temperature sensor of cascaded Lyot filter and Mach-Zehnder interferometer (MZI) based on the Vernier effect. The MZI, which has two consecutive bubble-type upper tapers, is employed as a reference interferometer owing to the exceptional stability of its totally polarization-maintaining fiber (PMF) construction. A Lyot filter is created by fusion splicing a segment of PMF at a 45° angle between two linear polarizers, functioning as a sensing interferometer. The sensitivity of the cascaded sensor improves through the Vernier effect, which is produced when the length of the sensing PMF in the Lyot filter is modified to closely match the free spectral range (FSR) of the MZI. Experimental results reveal the Lyot filter’s sensitivity to be -1.4 nm/°C, while the cascaded sensor achieves an increased sensitivity of -28.3 nm/°C, with a sensitivity amplification factor of 20.2. The proposed sensor structure, composed of PMF, leverages the controllable polarization characteristics of PMF to enhance system performance, effectively addressing the issue of detection error that arises from the fluctuating polarization state of the optical signal being transmitted throughout the sensitivity test. This proposed optical fiber temperature sensor, with its robust polarization stability, simple fabrication, and high sensitivity, is suitable for high-precision industrial applications.
- 26 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (15) , 23918-23928
Sensitivity-Enhanced Temperature Sensor of Cascaded Lyot Filter and Mach–Zehnder Interferometer Based on the Vernier Effect
The compact structure and resistance to electromagnetic interference of optical fiber temperature sensors have garnered significant interest. Nevertheless, it is imperative to enhance the detecting sensitivity in order to adequately fulfill the existing requirements. This study proposes and demonstrates a sensitivity-enhanced optical fiber temperature sensor of cascaded Lyot filter and Mach-Zehnder interferometer (MZI) based on the Vernier effect. The MZI, which has two consecutive bubble-type upper tapers, is employed as a reference interferometer owing to the exceptional stability of its totally polarization-maintaining fiber (PMF) construction. A Lyot filter is created by fusion splicing a segment of PMF at a 45° angle between two linear polarizers, functioning as a sensing interferometer. The sensitivity of the cascaded sensor improves through the Vernier effect, which is produced when the length of the sensing PMF in the Lyot filter is modified to closely match the free spectral range (FSR) of the MZI. Experimental results reveal the Lyot filter’s sensitivity to be -1.4 nm/°C, while the cascaded sensor achieves an increased sensitivity of -28.3 nm/°C, with a sensitivity amplification factor of 20.2. The proposed sensor structure, composed of PMF, leverages the controllable polarization characteristics of PMF to enhance system performance, effectively addressing the issue of detection error that arises from the fluctuating polarization state of the optical signal being transmitted throughout the sensitivity test. This proposed optical fiber temperature sensor, with its robust polarization stability, simple fabrication, and high sensitivity, is suitable for high-precision industrial applications.
- Open Access
Research on Magnetic-Induced Error of Small-Sized Fiber Optic Gyro Fiber Coil in Space Environment
Spacecraft is severely limited in weight and volume, resulting in a small bending radius of the fiber coil used by IFOG (Interference Fiber Optic Gyroscope). The fiber coil has such a size that the influence of bending on fiber birefringence cannot be ignored. In this paper, we research magnetic-induced errors of small-sized IFOG working in low orbit space. Firstly, we use the Jones matrix to analyze the effects of radial magnetic field and axial magnetic field on IFOG. Secondly, we establish a three-dimensional model for the radial magnetic-induced errors and magnetic-induced errors of minor radius fiber coil. Using the finite element method, we analyze the magnetic-induced error between different levels of the fiber coil. Combined with the birefringence distribution of the minor radius fiber coil, an accurate three-dimensional magnetic-induced error model is established. Thirdly, in the experiment, we design the magnetic-induced error test platform that includes the Fluke standard current source, transconductance amplifier, and Helmholtz coil. The experimental results show that, compared with the traditional calculation method, the three-dimensional magnetic-induced error model reduces the RMSE (Root Mean Square Error) of the radial magnetic field by 56.9% and the RMSE of the axial magnetic field by 35.7%, respectively.
Open AccessResearch on Magnetic-Induced Error of Small-Sized Fiber Optic Gyro Fiber Coil in Space Environment
Spacecraft is severely limited in weight and volume, resulting in a small bending radius of the fiber coil used by IFOG (Interference Fiber Optic Gyroscope). The fiber coil has such a size that the influence of bending on fiber birefringence cannot be ignored. In this paper, we research magnetic-induced errors of small-sized IFOG working in low orbit space. Firstly, we use the Jones matrix to analyze the effects of radial magnetic field and axial magnetic field on IFOG. Secondly, we establish a three-dimensional model for the radial magnetic-induced errors and magnetic-induced errors of minor radius fiber coil. Using the finite element method, we analyze the magnetic-induced error between different levels of the fiber coil. Combined with the birefringence distribution of the minor radius fiber coil, an accurate three-dimensional magnetic-induced error model is established. Thirdly, in the experiment, we design the magnetic-induced error test platform that includes the Fluke standard current source, transconductance amplifier, and Helmholtz coil. The experimental results show that, compared with the traditional calculation method, the three-dimensional magnetic-induced error model reduces the RMSE (Root Mean Square Error) of the radial magnetic field by 56.9% and the RMSE of the axial magnetic field by 35.7%, respectively.