Zia Emin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zia Emin has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
D.S. Crisford
Network Design, Network Strategy, National Grid Transco, Warwick, UK
1 shared publicationGeoff Love
1 shared publicationJinsheng Peng
1 shared publication
Latest Publications
- 7 March 2023
- Published by Elsevier in Electric Power Systems Research
- Vol. 220
Transformer and line energisation via grid forming converter based on multi-loop droop control
- 7 March 2023
- Published by Elsevier in Electric Power Systems Research
- Vol. 220
Transformer and line energisation via grid forming converter based on multi-loop droop control
- 26 June 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 21 (3) , 1607-1612
Negative Phase-Sequence Voltages on E&W Transmission System
In the absence of phase transposition, overhead lines are a major source of unbalance in both currents and voltages on the transmission system. In the England and Wales (E&W) transmission system, the individual circuits are phased such that the average unbalance produced is minimized. The main negative phase-sequence (NPS) voltages on the transmission system arise at loop-in points for generation and load connection under an outage condition of one of the connection circuits and where there is a large NPS voltage induction from the parallel circuit. If not limited, excessive unbalance can cause system incidents and lead to damage of power system equipment.
- 26 June 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 21 (3) , 1607-1612
Negative Phase-Sequence Voltages on E&W Transmission System
In the absence of phase transposition, overhead lines are a major source of unbalance in both currents and voltages on the transmission system. In the England and Wales (E&W) transmission system, the individual circuits are phased such that the average unbalance produced is minimized. The main negative phase-sequence (NPS) voltages on the transmission system arise at loop-in points for generation and load connection under an outage condition of one of the connection circuits and where there is a large NPS voltage induction from the parallel circuit. If not limited, excessive unbalance can cause system incidents and lead to damage of power system equipment.