Shouying Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shouying Wang has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Cong Kong
East China Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Shanghai 200090, China
5 shared publications - Essy Kouadio Fodjo
Laboratory of Constitution and Reaction of Matter, UFR SSMT, Felix Houphouet Boigny University, 22 BP 582 Abidjan 22, Cote d’Ivoire
3 shared publications - Wenshuai Si
The Institute of Agro-Food Standards and Testing Technology, Shanghai Academy of Agricultural Sciences, Shanghai 201403, China
3 shared publications - Bing Bai
Institute for Agro-Food Standards and Testing Technology, Shanghai Academy of Agricultural Sciences, Shanghai, China
2 shared publications - Guangxin Yang
East China Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Shanghai 200090, China
2 shared publications - Huijuan Yu
Key Laboratory of East China Sea Fishery Resources Exploitation, Ministry of Agriculture and Rural Affairs, East China Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Shanghai 200090, China
2 shared publications
Latest Publications
- 12 December 2023
- Published by Taylor & Francis in Food Additives & Contaminants: Part B
- Vol. 17 (1) , 35-45
HRMS analysis of pesticides in vegetables from Shanghai and risk assessment
A rapid analytical method for the simultaneous determination of 550 pesticide residues in vegetable samples was developed based on ultra-high performance liquid chromatography-tandem Q/Orbitrap high-resolution mass spectrometry (UPLC-Q/Orbitrap-HRMS). To investigate the risk of exposure to pesticide residues through vegetable consumption, 704 leafy vegetable samples from Shanghai were analysed for multiple residues using this method. A total of 54 pesticide residues were identified in these vegetable samples and 302 samples contained one or more pesticide residue. The levels of the detected pesticides did not pose a health risk in the long term and were acceptable according to the results of the chronic dietary risk assessment. Risk rankings displayed that most of the pesticides were low to medium risk. The findings of this study provide a reference for future pesticide monitoring programmes.
- 12 December 2023
- Published by Taylor & Francis in Food Additives & Contaminants: Part B
- Vol. 17 (1) , 35-45
HRMS analysis of pesticides in vegetables from Shanghai and risk assessment
A rapid analytical method for the simultaneous determination of 550 pesticide residues in vegetable samples was developed based on ultra-high performance liquid chromatography-tandem Q/Orbitrap high-resolution mass spectrometry (UPLC-Q/Orbitrap-HRMS). To investigate the risk of exposure to pesticide residues through vegetable consumption, 704 leafy vegetable samples from Shanghai were analysed for multiple residues using this method. A total of 54 pesticide residues were identified in these vegetable samples and 302 samples contained one or more pesticide residue. The levels of the detected pesticides did not pose a health risk in the long term and were acceptable according to the results of the chronic dietary risk assessment. Risk rankings displayed that most of the pesticides were low to medium risk. The findings of this study provide a reference for future pesticide monitoring programmes.
- Open Access
Development of a Zeolite H-ZSM-5-Based D-μSPE Method for the Determination of Organophosphorus Pesticides in Tea Beverages
In this study, a novel dispersive micro-solid phase extraction (D-μSPE) technique with H-ZSM-5 zeolite as an adsorbent was developed for the determination of 21 trace pesticides in tea beverages. The adsorption and desorption of H-ZSM-5 zeolites were investigated based on structural characteristics and adsorption properties similar to those of H-beta zeolites. In combination with the properties of the adsorbates, it was explained that the adsorption reaction occurred on the microporous surface and mesopores of H-ZSM-5. Based on optimal parameters, the beverage samples were extracted by 50 mg of zeolite within 1 min. The zeolite was eluted with 2 mL of an acetonitrile-water mixture after separation, and the eluent was filtered prior to HPLC-MS/MS analysis. The D-μSPE protocol demonstrated acceptable accuracy and precision, with recoveries between 62.1% and 106.6% and relative standard deviations of 1.4% to 12.6%, as validated by analytical reliability. The correlation coefficient in the linear range of 0.2–50 ng·mL−1 was greater than 0.98, with limits of detection of 0.05–0.1 ng·mL−1 and limits of quantification of 0.1–0.2 ng·mL−1. The matrix effects ranged from 76.2% to 112.7%. The results indicate that the novel D-μSPE technique based on H-ZSM-5 is a rapid, simple, green and economical method for the determination of pesticide residues in tea beverages. The proposed method achieved simultaneously low adsorbent dosage, 20-fold enrichment factor, rapid pre-concentration in 12 min, minimal organic wastes, and effective reduction of matrix interference.
Open AccessDevelopment of a Zeolite H-ZSM-5-Based D-μSPE Method for the Determination of Organophosphorus Pesticides in Tea Beverages
In this study, a novel dispersive micro-solid phase extraction (D-μSPE) technique with H-ZSM-5 zeolite as an adsorbent was developed for the determination of 21 trace pesticides in tea beverages. The adsorption and desorption of H-ZSM-5 zeolites were investigated based on structural characteristics and adsorption properties similar to those of H-beta zeolites. In combination with the properties of the adsorbates, it was explained that the adsorption reaction occurred on the microporous surface and mesopores of H-ZSM-5. Based on optimal parameters, the beverage samples were extracted by 50 mg of zeolite within 1 min. The zeolite was eluted with 2 mL of an acetonitrile-water mixture after separation, and the eluent was filtered prior to HPLC-MS/MS analysis. The D-μSPE protocol demonstrated acceptable accuracy and precision, with recoveries between 62.1% and 106.6% and relative standard deviations of 1.4% to 12.6%, as validated by analytical reliability. The correlation coefficient in the linear range of 0.2–50 ng·mL−1 was greater than 0.98, with limits of detection of 0.05–0.1 ng·mL−1 and limits of quantification of 0.1–0.2 ng·mL−1. The matrix effects ranged from 76.2% to 112.7%. The results indicate that the novel D-μSPE technique based on H-ZSM-5 is a rapid, simple, green and economical method for the determination of pesticide residues in tea beverages. The proposed method achieved simultaneously low adsorbent dosage, 20-fold enrichment factor, rapid pre-concentration in 12 min, minimal organic wastes, and effective reduction of matrix interference.
- Open Access
Multi-Residue Screening of Pesticides in Aquatic Products Using High-Performance Liquid Chromatography-Tandem High-Resolution Mass Spectrometry
Pesticide residues in aquatic products are of great concern due to the risk of environmental transmission and their extensive use in aquaculture. In our work, a quick screening approach was developed for the qualitative and semi-quantitative screening of 87 pesticide residues in aquatic products. The sample preparation was investigated, including extract solvent, extract methods, buffer salts, lipid removal, cleanup materials and filter membranes for aquatic products. Samples were extracted using a modified QuEChERS procedure, and two clean-up procedures were developed for UHPLC-Q/Orbitrap MS analysis based on the fat content of the aquatic products. The screening detection limits for all studied pesticides were distributed between 1 and 500 μg/kg in the three representative matrices. Seventy-one pesticides could be analyzed with a screening limit between 1 and 25 μg/kg in grass carp and crayfish, sixty-one pesticides could be screened for limits between 1 and 50 μg/kg in crab. The accuracy results showed that recoveries ranged from 50 to 120% for 60, 56 and 52 pesticides at medium-level for grass carp, crayfish and crab, respectively. At high spiking levels, 74, 65 and 59 pesticides were recovered within the range of 50–120% for the three matrices, respectively. The relative standard deviations of most compounds in different matrices were less than 20%. With this method, the local farmed aquatic products were tested for pesticide residues. In these samples, ethoxyquinoline, prometryn and phoxim were frequently detected. The majority of these confirmed compounds did not exceed 2.00 μg/kg. A grass carp with trichlorfon at 4.87 μg/kg and two carps with ethoxyquinoline at 200 µg/kg were detected, indicating the potential dietary risk.
Open AccessMulti-Residue Screening of Pesticides in Aquatic Products Using High-Performance Liquid Chromatography-Tandem High-Resolution Mass Spectrometry
Pesticide residues in aquatic products are of great concern due to the risk of environmental transmission and their extensive use in aquaculture. In our work, a quick screening approach was developed for the qualitative and semi-quantitative screening of 87 pesticide residues in aquatic products. The sample preparation was investigated, including extract solvent, extract methods, buffer salts, lipid removal, cleanup materials and filter membranes for aquatic products. Samples were extracted using a modified QuEChERS procedure, and two clean-up procedures were developed for UHPLC-Q/Orbitrap MS analysis based on the fat content of the aquatic products. The screening detection limits for all studied pesticides were distributed between 1 and 500 μg/kg in the three representative matrices. Seventy-one pesticides could be analyzed with a screening limit between 1 and 25 μg/kg in grass carp and crayfish, sixty-one pesticides could be screened for limits between 1 and 50 μg/kg in crab. The accuracy results showed that recoveries ranged from 50 to 120% for 60, 56 and 52 pesticides at medium-level for grass carp, crayfish and crab, respectively. At high spiking levels, 74, 65 and 59 pesticides were recovered within the range of 50–120% for the three matrices, respectively. The relative standard deviations of most compounds in different matrices were less than 20%. With this method, the local farmed aquatic products were tested for pesticide residues. In these samples, ethoxyquinoline, prometryn and phoxim were frequently detected. The majority of these confirmed compounds did not exceed 2.00 μg/kg. A grass carp with trichlorfon at 4.87 μg/kg and two carps with ethoxyquinoline at 200 µg/kg were detected, indicating the potential dietary risk.
- Open Access
Improved LC/MS/MS Quantification Using Dual Deuterated Isomers as the Surrogates: A Case Analysis of Enrofloxacin Residue in Aquatic Products
Extensive and high residue variations in enrofloxacin (ENR) exist in different aquatic products. A novel quantitative method for measuring ENR using high-performance liquid chromatography–tandem mass spectrometry was developed employing enrofloxacin-d5 (ENR-d5) and enrofloxacin-d3 (ENR-d3) as isotope surrogates. This reduced the deviation of detected values, which results from the overpass of the linear range and/or the large difference in the residue between the isotope standard and ENR, from the actual content. Furthermore, high residue levels of ENR can be directly diluted and re-calibrated by the corresponding curve with the addition of high levels of another internal surrogate without repeated sample preparation, avoiding the overflow of the instrument response. The validation results demonstrated that the method can simultaneously determine ENR residues from MQL (2 µg/kg) to 5000 × MQL (method quantification limit) with recoveries between 97.1 and 106%, and intra-precision of no more than 2.14%. This method realized a wide linear calibration range with dual deuterated isomers, which has not been previously reported in the literature. The developed method was successfully applied to the analysis of ENR in different aquatic products, with ENR residue levels varying from 108 to 4340 μg/kg and an interval of precision in the range of 0.175~6.72%. These results demonstrate that batch samples with a high variation in ENR residues (over the linear range with a single isotope standard) can be detected by the dual isotope surrogates method in a single sample preparation process.
Open AccessImproved LC/MS/MS Quantification Using Dual Deuterated Isomers as the Surrogates: A Case Analysis of Enrofloxacin Residue in Aquatic Products
Extensive and high residue variations in enrofloxacin (ENR) exist in different aquatic products. A novel quantitative method for measuring ENR using high-performance liquid chromatography–tandem mass spectrometry was developed employing enrofloxacin-d5 (ENR-d5) and enrofloxacin-d3 (ENR-d3) as isotope surrogates. This reduced the deviation of detected values, which results from the overpass of the linear range and/or the large difference in the residue between the isotope standard and ENR, from the actual content. Furthermore, high residue levels of ENR can be directly diluted and re-calibrated by the corresponding curve with the addition of high levels of another internal surrogate without repeated sample preparation, avoiding the overflow of the instrument response. The validation results demonstrated that the method can simultaneously determine ENR residues from MQL (2 µg/kg) to 5000 × MQL (method quantification limit) with recoveries between 97.1 and 106%, and intra-precision of no more than 2.14%. This method realized a wide linear calibration range with dual deuterated isomers, which has not been previously reported in the literature. The developed method was successfully applied to the analysis of ENR in different aquatic products, with ENR residue levels varying from 108 to 4340 μg/kg and an interval of precision in the range of 0.175~6.72%. These results demonstrate that batch samples with a high variation in ENR residues (over the linear range with a single isotope standard) can be detected by the dual isotope surrogates method in a single sample preparation process.
- Open Access
- 25 April 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (9) , 4316
Zeolite H-Beta as a Dispersive Solid-Phase Extraction Sorbent for the Determination of Eight Neonicotinoid Insecticides Using Ultra-High-Performance Liquid Chromatography—Tandem Mass Spectrometry
In this study, a dispersive solid-phase extraction (DSPE) pretreatment procedure using zeolite H-Beta as a sorbent was exploited for the determination of eight neonicotinoids in bottled water and honey products based on ultra-high-performance liquid chromatography–tandem mass spectrometry analysis. The zeolite H-Beta was demonstrated to be a suitable sorbent for neonicotinoid insecticides, even after 10 recycles of reuse. The method performance was evaluated by the linearity (R2 ≥ 0.998), recovery (71–108%), precision (0.1–7.8%), limit of detection (0.05–0.1 ng/mL) and limit of quantification (0.1–0.2 ng/mL), which suggested excellent stability and high sensitivity with the use of the DSPE procedure. The method was further successfully applied in the test of neonicotinoid insecticides in 34 samples. Zeolite H-Beta shows promise as an efficient and practical material for monitoring neonicotinoid insecticides in bottled water and multiplex honey matrices.
- 25 April 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (9) , 4316
Open AccessZeolite H-Beta as a Dispersive Solid-Phase Extraction Sorbent for the Determination of Eight Neonicotinoid Insecticides Using Ultra-High-Performance Liquid Chromatography—Tandem Mass Spectrometry
In this study, a dispersive solid-phase extraction (DSPE) pretreatment procedure using zeolite H-Beta as a sorbent was exploited for the determination of eight neonicotinoids in bottled water and honey products based on ultra-high-performance liquid chromatography–tandem mass spectrometry analysis. The zeolite H-Beta was demonstrated to be a suitable sorbent for neonicotinoid insecticides, even after 10 recycles of reuse. The method performance was evaluated by the linearity (R2 ≥ 0.998), recovery (71–108%), precision (0.1–7.8%), limit of detection (0.05–0.1 ng/mL) and limit of quantification (0.1–0.2 ng/mL), which suggested excellent stability and high sensitivity with the use of the DSPE procedure. The method was further successfully applied in the test of neonicotinoid insecticides in 34 samples. Zeolite H-Beta shows promise as an efficient and practical material for monitoring neonicotinoid insecticides in bottled water and multiplex honey matrices.
- Open Access
Multi-Residue Screening of Pesticides in Aquaculture Waters through Ultra-High-Performance Liquid Chromatography-Q/Orbitrap Mass Spectrometry
Pesticide residues in foodstuffs can lead to several undesirable effects. A simple and high-throughput targeted screening method analyzing multi-residue pesticide in aquaculture water based on ultra-high-performance liquid chromatography-Q/Orbitrap mass spectrometry (UHPLC-Q/Orbi MS) was developed and validated. In this technique, the peaks of the compound using precursor ions were recorded by the full scan, which was used for rough quantitative analysis with single point matrix matched calibration. The qualitative identification was performed following the stringent confirmation criteria with fragment ions, retention time, and an isotopic pattern. Additionally, solid-phase extraction with an HLB (Hydrophilic/Lipophilic Balanced) column was selected to enrich and separate target pesticides from water. The screening detection limit of 33 compounds are less than 2 ng·L−1, while 26 compounds range from 2 ng·L−1 to 10 ng·L−1, 19 compounds are at the range of 10–200 ng·L−1, and the other two compounds are 200 ng·L−1 and 1000 ng·L−1. Most of the recovery results were found to be between 60~130%. Finally, the method was successfully applied to the analysis of pesticide residues in 30 water samples from aquaculture environment in Shanghai, indicating its applicability in pesticide screening for environmental monitoring.
Open AccessMulti-Residue Screening of Pesticides in Aquaculture Waters through Ultra-High-Performance Liquid Chromatography-Q/Orbitrap Mass Spectrometry
Pesticide residues in foodstuffs can lead to several undesirable effects. A simple and high-throughput targeted screening method analyzing multi-residue pesticide in aquaculture water based on ultra-high-performance liquid chromatography-Q/Orbitrap mass spectrometry (UHPLC-Q/Orbi MS) was developed and validated. In this technique, the peaks of the compound using precursor ions were recorded by the full scan, which was used for rough quantitative analysis with single point matrix matched calibration. The qualitative identification was performed following the stringent confirmation criteria with fragment ions, retention time, and an isotopic pattern. Additionally, solid-phase extraction with an HLB (Hydrophilic/Lipophilic Balanced) column was selected to enrich and separate target pesticides from water. The screening detection limit of 33 compounds are less than 2 ng·L−1, while 26 compounds range from 2 ng·L−1 to 10 ng·L−1, 19 compounds are at the range of 10–200 ng·L−1, and the other two compounds are 200 ng·L−1 and 1000 ng·L−1. Most of the recovery results were found to be between 60~130%. Finally, the method was successfully applied to the analysis of pesticide residues in 30 water samples from aquaculture environment in Shanghai, indicating its applicability in pesticide screening for environmental monitoring.
- Open Access
Screening 89 Pesticides in Fishery Drugs by Ultrahigh Performance Liquid Chromatography Tandem Quadrupole-Orbitrap Mass Spectrometer
Multiclass screening of drugs with high resolution mass spectrometry is of great interest due to its high time-efficiency and excellent accuracy. A high-scale, fast screening method for pesticides in fishery drugs was established based on ultrahigh performance liquid chromatography tandem quadrupole-Orbitrap high-resolution mass spectrometer. The target compounds - were diluted in methanol and extracted by ultrasonic treatment, and the extracts were diluted with MeOH-water (1:1, v/v) and centrifuged to remove impurities. The chromatographic separation was performed on an Accucore aQ-MS column (100 mm × 2.1 mm, 2.6 μm) with gradient elution using 0.1% formic acid in water (containing 5 mmol/L ammonium formate) and 0.1% formic acid in methanol (containing 5 mmol/L ammonium formate) in Full Scan/dd-MS2 (TopN) scan mode. A screening database, including mass spectrometric and chromatographic information, was established for identification of compounds. The screening detection limits of methods ranged between 1–500 mg/kg, the recoveries of real samples spiked with the concentration of 10 mg/kg and 100 mg/kg standard mixture ranged from 70% to 110% for more than sixty compounds, and the relative standard deviations (RSDs) were less than 20%. The application of this method showed that target pesticides were screened out in 10 samples out of 21 practical samples, in which the banned pesticide chlorpyrifos were detected in 3 out of the 10 samples.
Open AccessScreening 89 Pesticides in Fishery Drugs by Ultrahigh Performance Liquid Chromatography Tandem Quadrupole-Orbitrap Mass Spectrometer
Multiclass screening of drugs with high resolution mass spectrometry is of great interest due to its high time-efficiency and excellent accuracy. A high-scale, fast screening method for pesticides in fishery drugs was established based on ultrahigh performance liquid chromatography tandem quadrupole-Orbitrap high-resolution mass spectrometer. The target compounds - were diluted in methanol and extracted by ultrasonic treatment, and the extracts were diluted with MeOH-water (1:1, v/v) and centrifuged to remove impurities. The chromatographic separation was performed on an Accucore aQ-MS column (100 mm × 2.1 mm, 2.6 μm) with gradient elution using 0.1% formic acid in water (containing 5 mmol/L ammonium formate) and 0.1% formic acid in methanol (containing 5 mmol/L ammonium formate) in Full Scan/dd-MS2 (TopN) scan mode. A screening database, including mass spectrometric and chromatographic information, was established for identification of compounds. The screening detection limits of methods ranged between 1–500 mg/kg, the recoveries of real samples spiked with the concentration of 10 mg/kg and 100 mg/kg standard mixture ranged from 70% to 110% for more than sixty compounds, and the relative standard deviations (RSDs) were less than 20%. The application of this method showed that target pesticides were screened out in 10 samples out of 21 practical samples, in which the banned pesticide chlorpyrifos were detected in 3 out of the 10 samples.