CSCarolyn M. Sommerich

Carolyn M. Sommerich

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Carolyn M. Sommerich has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Assessing Situation-Level Sonographer Workload

    by Carolyn M. Sommerich, Jody Kutney, Kevin D. Evans

    Objective: Ideally, schedules should provide sufficient time for quality patient examinations, sufficient time for other examination-related activities, and recovery time for sonographers. One difficulty with examination times and scheduling is the variability among examinations due to a myriad of factors. The objective of this work was an improved understanding of these factors and their relation to sonographer workload, potentially leading to better-informed scheduling in the future. Materials and Methods: A collaborative approach was used to (1) develop a list of potential workload-contributing factors, (2) document factor occurrence during examinations, and (3) explore associations between workload factors and perceived workload. Results: Notable differences were seen in workload between examinations. The association between total number of workload factors and perceived workload was stronger than between workload variables and examination duration. Conclusion: This supports the concept that more dynamic, flexible scheduling that accounts for situation-level workload experiences may aid in providing more appropriate and sustainable workloads for sonographers.

  • When One Size Doesn’t Fit All: Efficacy Assessment of an Engineering Control for Endoscopic Procedures

    by Ke Ding, Anas Kachlan, Paula Baluyut, Carolyn M. Sommerich

    Studies report an elevated prevalence of endoscopy-related musculoskeletal disorders in gastroenterologists. Interventions primarily address work environment and work organization, not tool design (the endoscope). This study evaluated an add-on adjustable support strap designed to reduce the workload of the user’s left hand, which operates the endoscope’s control section. Study participants (four women, seven men) were experienced in endoscopy. Each participant performed two simulated colonoscopies with the support strap and two without (within-subjects design). Effects of the support strap were assessed using normalized muscle activity (nEMG) from surface electrodes over finger and wrist flexors and extensors and trapezius m., video, and usability data. With the strap, nEMG was reduced in most muscles for three participants (all women); mixed results for four, and no reduced nEMG for four others (all men). Mode of ratings of usability, usefulness, and desirability were 7, 5, 5, respectively (7 = very good). Results suggest benefits for some users.

  • Open Access

    A field test of the EMS LiftKit: Validating its usability, usefulness, and desirability

    by Steven A. Lavender, Carolyn M. Sommerich, Anas Kachlan


  • Identifying ergonomics practices currently used by grocery distribution centers

    by Steven A. Lavender, Carolyn M. Sommerich, Anas Kachlan


  • Assessment of OB/Gyn Residents’ Knowledge of Basic Obstetric Sonography and Psychomotor Skills Posttraining on a Computer-Based Simulator

    by Sundus H. Mohammad, Carolyn M. Sommerich, Angela N. Butwin, Kevin D. Evans

    Objective: This study sought to evaluate how a high-fidelity computer-based sonography simulator (FCBSS) can be used in training obstetrics and gynecology residents and evaluate efficacy of high-fidelity CBSS in enhancing resident’s sonographic knowledge, psychomotor skills, and level of confidence in performing sonographic fetal assessments. Materials and Methods: Eleven postgraduate year 1 residents (PGY1s) and ten PGY2s were assessed on sonographic performance by measuring psychomotor skills and evaluating the accuracy of the sonographic images. PGY2s received traditional sonography training while PGY1s received three individualized training sessions on a high-fidelity CBSS. At the conclusion, all residents received feedback and completed a survey to establish their current confidence level in performing and interpreting sonograms. Results: PGY2s scored a median of 33/66 points on the assessment, while PGY1s scored a median of 64/66 points. Statistical analysis performed from motion analysis metrics between cohorts revealed a statistically significant difference, with PGY1s demonstrating higher psychomotor skills. Interquartile ranges of PGY1s’ scores were smaller than PGY2s’, revealing consistency in knowledge and skills among the PGY1 cohort. Conclusion: Findings suggests that high-fidelity CBSS can be used effectively in training residents. It also demonstrates that implementation of formalized sonography training, using a high-fidelity CBSS, can be achieved and potentially expedite and enhance the learning of novice learners.


  • Open Access

    Efficacy and Usability of a Virtual Simulation Training System for Health and Safety Hazards Encountered by Healthcare Workers

    by Barbara J. Polivka, Sarah Anderson, Steve A. Lavender, Carolyn M. Sommerich, Donald L. Stredney, Celia E. Wills, Amy R. Darragh

    Objective: This study evaluated the efficacy, usability, usefulness, and desirability (UUD) of a Home Healthcare Interactive Virtual Simulation Training System (HH-VSTS) designed to train home healthcare workers (HHWs) and healthcare students to identify and respond to health and safety hazards in client homes. Materials and Methods: Participants were randomly assigned to either the HH-VSTS training group or to the paper-based training group. The HH-VSTS group completed three HH-VSTS Training Modules on a laptop/desktop computer. The training modules addressed hazard identification, hazard rationale, and hazard response to electric/fire/burn, slip/trip/lift, and environmental hazards. The paper-based training group reviewed identical information in a written hard-copy format. Both groups completed an HH-VSTS Assessment module. Participants completed demographic/background and UUD questionnaires, and in-system metrics measured their performance on hazard identification, rationale, and response. Results: Participants (n = 74) were HHWs and students in health profession programs. There were no significant differences in participants' ability to correctly identify hazards, rationale, or how to address them. Participants identified over 90% of hazards, although fewer participants were able to correctly identify what makes an item a hazard or how to manage it. For those in the HH-VSTS group, over 83% found the HH-VSTS easy to use, over 94% agreed the HH-VSTS was useful, and over 80% liked it. Conclusion: The HH-VSTS provided and engaging, efficacious training that was as effective as a typical paper-based training. In addition, the HH-VSTS is usable by a variety of end users, regardless of computer or gaming experience.


  • Utilization of Sonography Compared With Magnetic Resonance Imaging in Determining the Cross-Sectional Area of the Median Nerve in a Sample of Working Macaca fascicularis

    by Kevin R. Volz, Kevin D Evans, Larry Tyler Fout, Cristina Hutmire, Carolyn M. Sommerich, John A Buford

    A preclinical study of 15 Macaca fascicularis monkeys was conducted to determine (1) the ability of detecting median mononeuropathy (MMN) within the median nerve after a work intervention and (2) the relationship between the layers of the median nerve during an acute inflammatory process by using sonography in conjunction with magnetic resonance imaging (MRI). Cross-sectional areas (CSAs) were imaged using MRI and sonography proximal to the carpal tunnel inlet (defined by the most distal portion of the radius) and further distal into the carpal tunnel (defined by the most proximal portion of the pisiform) at the prework exposure stage. CSAs measured on the outer edge of the median nerve were obtained from both modalities, at both anatomical locations. An intermodality t test demonstrated no statistical differences between the two sets of measurements (radius, P ≤ .15; pisiform, P ≤ .46). At the postwork exposure stage, sonographic measurements were obtained on the outer and inner borders of the median nerve at both anatomical levels. A two-tailed t test showed statistically significant differences within the carpal tunnel comparing pre- and postwork CSA measurements (radius, P ≤ .01; pisiform, P ≤ .297). The epineurial layer area was then determined as the difference between outer-border and inner-border CSAs. Pearson correlations between the epineurial layer and overall median nerve CSA within the carpal tunnel demonstrated a strong positive correlation that was statistically significant (r = 0.97; P ≤ .01) after postwork exposure. Possible factors contributing to this acute phase of MMN could be hyperemia within the layers of the nerve and the development of Renault bodies. This work would need to be translated to human studies for further confirmation of the anatomic and clinical significance of this effect.


  • Measuring pad–pad pinch strength in a non-human primate: Macaca fascicularis

    by Jacob J. Banks, Steven A. Lavender, John A. Buford, Carolyn M. Sommerich


  • Carpal Tunnel Pressure during Typing: Effects of Wrist Posture and Typing Speed

    by Carolyn M. Sommerich

    With increasing frequency, reports appear in the popular press linking hand and wrist musculoskeletal disorders (MSDs) with keyboard work. Excessive ulnar deviation and self-perceived fast typing speed are two of the many risk factors identified through various epidemiological studies of upper extremity MSD symptoms among those working with keyboards. Yet no study has offered quantitative, biomechanical evidence to explain how these factors might contribute to MSD development. A study was designed to examine carpal tunnel pressure (CTP) during typing, and the effect of radial-ulnar wrist posture and typing speed on CTP. Female subjects typed on a commercially-available keyboard which was oriented in standard and in split configurations. In the split arrangement ulnar deviation was eased in all but one wrist. In the split arrangement, all subjects demonstrated a decrease in CTP concomitant with a decrease in ulnar wrist deviation. However, only one subject exhibited CTP which significantly exceeded pressure thresholds identified in the literature. CTP appeared to be subject-specific in nature. Typing speed was found to affect peak CTP in half of the subjects.