Xin Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xin Zhao has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
- Sheng Han
School of Chemical and Environmental Engineering, Shanghai Institute of Technology, Shanghai 201400, China
6 shared publications - Chenchen Wang
School of Chemical and Environmental Engineering Shanghai Institute of Technology 201418 Shanghai China
5 shared publications Hao Cao
Department of Chemical Engineering and Energy Technology, Shanghai Institute of Technology, Shanghai, 201418, China
4 shared publicationsYanan Li
School of Chemical and Environmental Engineering Shanghai Institute of Technology 201418 Shanghai China
3 shared publicationsPanpan Tian
School of Chemical and Environmental Engineering, Shanghai Institute of Technology, 201418, Shanghai, China; Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, 200041, Shanghai, China
2 shared publicationsRujiang Wang
Department of Joint surgery Yangquan Coal Industry (Group) General Hospital 045008 Yangquan Shanxi China
2 shared publications
Latest Publications
- Open Access
- 1 August 2026
- Published by Tsinghua University Press in Friction
- Vol. 14 (8)
A self-healing bio-lubricating hydrogel coating synergistically enhanced with ZIF-8 nanoparticles, exhibiting corrosion resistance, antibacterial properties, and wear resistance
Hydrogel is an ideal material for replacing natural articular cartilage. However, their inadequate mechanical properties, such as severe dynamic damage, restricted its application in the field of joint replacement. Herein, based on Schiff base bond (dialdehyde starch (DS) with acrylamide (AM)) and metal coordination bond (Fe3+ with DS), we designed a self-healing bio-lubricant hydrogel coating (DS/AM/Fe3+). Moreover, the nano-composite metal-organic framework (ZIF-8) was applied to the DS/AM/Fe3+ hydrogels to improve its mechanical properties. The 1000ppmZIF-8/DS/AM/Fe3+ hydrogel coatings show excellent tribological properties and corrosion resistance, with wear rate reduced by 32.94%, friction coefficient reduced to 0.104, corrosion inhibition efficiency up to 79.63%, and active antibacterial and biological activity. The designed hydrogel provides potential applications for artificial joint replacement.
- 1 August 2026
- Published by Tsinghua University Press in Friction
- Vol. 14 (8)
Open AccessA self-healing bio-lubricating hydrogel coating synergistically enhanced with ZIF-8 nanoparticles, exhibiting corrosion resistance, antibacterial properties, and wear resistance
Hydrogel is an ideal material for replacing natural articular cartilage. However, their inadequate mechanical properties, such as severe dynamic damage, restricted its application in the field of joint replacement. Herein, based on Schiff base bond (dialdehyde starch (DS) with acrylamide (AM)) and metal coordination bond (Fe3+ with DS), we designed a self-healing bio-lubricant hydrogel coating (DS/AM/Fe3+). Moreover, the nano-composite metal-organic framework (ZIF-8) was applied to the DS/AM/Fe3+ hydrogels to improve its mechanical properties. The 1000ppmZIF-8/DS/AM/Fe3+ hydrogel coatings show excellent tribological properties and corrosion resistance, with wear rate reduced by 32.94%, friction coefficient reduced to 0.104, corrosion inhibition efficiency up to 79.63%, and active antibacterial and biological activity. The designed hydrogel provides potential applications for artificial joint replacement.
- Open Access
- 29 January 2026
- Published by Elsevier in Materials Today Bio
- Vol. 37, 102879
3D-printed titanium scaffolds coated with a multifunctional photothermal-responsive hydrogel promote osteoporotic bone defect repair
- 29 January 2026
- Published by Elsevier in Materials Today Bio
- Vol. 37, 102879
Open Access3D-printed titanium scaffolds coated with a multifunctional photothermal-responsive hydrogel promote osteoporotic bone defect repair
- Open Access
- 1 November 2025
- Published by Tsinghua University Press in Friction
- Vol. 13 (11)
A novel hydroxyapatite modified MXene-based hydrogel coating on Ti6Al4V alloy with improved biotribological properties and corrosion resistance
As a commonly used bone implant, Ti6Al4V alloy is prone to wear in human environment due to its corrosion resistance and poor wear resistance, resulting in their aseptic loosening and even implantation failure. Here, inspired of mussel adhesion chemistry, a novel hydrogel coating based on hydroxyapatite-modified MXene (PVA/PAA/PDA/HA-MXene) using a sol-gel method involving cyclic freezing and thawing, as well as chemical self-assembly techniques, on the surface of titanium alloy. The corrosion resistance and biotribological behaviors of the hydrogel coating on cortical bone were studied in simulated body fluid (SBF). The results demonstrated that the HA-MXene-based hydrogel coating exhibited outstanding biotribological and anti-corrosion properties. The novel HA-MXene-based hydrogel coatings can validly reduce the wear rate of cortical bone by 88.0 %, due to the formed lubrication film on the surface of hydrogel and the sliding and rolling friction mechanisms. Moreover, the enhanced anticorrosion properties of hydrogel coatings, optimally when the quantityof MXene arrived to 0.05 wt.%, were attributed to the blocking effect of MXene-based hydrogel. This study provides an innovative idea of surface modification design for the application of titanium alloy implants in the field of orthopedics.
- 1 November 2025
- Published by Tsinghua University Press in Friction
- Vol. 13 (11)
Open AccessA novel hydroxyapatite modified MXene-based hydrogel coating on Ti6Al4V alloy with improved biotribological properties and corrosion resistance
As a commonly used bone implant, Ti6Al4V alloy is prone to wear in human environment due to its corrosion resistance and poor wear resistance, resulting in their aseptic loosening and even implantation failure. Here, inspired of mussel adhesion chemistry, a novel hydrogel coating based on hydroxyapatite-modified MXene (PVA/PAA/PDA/HA-MXene) using a sol-gel method involving cyclic freezing and thawing, as well as chemical self-assembly techniques, on the surface of titanium alloy. The corrosion resistance and biotribological behaviors of the hydrogel coating on cortical bone were studied in simulated body fluid (SBF). The results demonstrated that the HA-MXene-based hydrogel coating exhibited outstanding biotribological and anti-corrosion properties. The novel HA-MXene-based hydrogel coatings can validly reduce the wear rate of cortical bone by 88.0 %, due to the formed lubrication film on the surface of hydrogel and the sliding and rolling friction mechanisms. Moreover, the enhanced anticorrosion properties of hydrogel coatings, optimally when the quantityof MXene arrived to 0.05 wt.%, were attributed to the blocking effect of MXene-based hydrogel. This study provides an innovative idea of surface modification design for the application of titanium alloy implants in the field of orthopedics.
- 9 May 2025
- Published by Elsevier in Experimental Cell Research
- Vol. 449 (2) , 114593
Magnesium promoting OVX rats’ rotator cuff tear repair with relieving stem cell senescence effect
- 9 May 2025
- Published by Elsevier in Experimental Cell Research
- Vol. 449 (2) , 114593
Magnesium promoting OVX rats’ rotator cuff tear repair with relieving stem cell senescence effect
- 5 December 2024
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 683 (Pt 1) , 521-530
Dynamic and sustainable supramolecular biolubrication coatings through nanoarchitectonics with dynamic B N bonding
- 5 December 2024
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 683 (Pt 1) , 521-530
Dynamic and sustainable supramolecular biolubrication coatings through nanoarchitectonics with dynamic B N bonding
- 3 April 2024
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 19 (9) , 1723-1731
Incremental regression of localization context for automatic segmentation of ossified ligamentum flavum from CT data
Purpose Segmentation of ossified ligamentum flavum (OLF) plays a crucial role in developing computer-assisted, image-guided systems for decompressive thoracic laminectomy. Manual segmentation is time-consuming, tedious, and label-intensive. It also suffers from inter- and intra-observer variability. Automatic segmentation is highly desired. Methods A two-stage, localization context-aware framework is developed for automatic segmentation of ossified ligamentum flavum. In the first stage, localization heatmaps of OLFs are obtained via incremental regression. In the second stage, the obtained heatmaps are then treated as the localization context for a segmentation U-Net. Our framework can directly map a whole volumetic data to its volume-wise labels. Results We designed and conducted comprehensive experiments on datasets of 100 patients to evaluate the performance of the proposed method. Our method achieved an average Dice similarity coefficient of 61.2 ± 7.6%, an average surface distance of 1.1 ± 0.5 mm, and an average positive predictive value of 62.0 ± 12.8%. Conclusion To the best knowledge of the authors, this is the first study aiming for automatic segmentation of ossified ligamentum flavum. Results from the comprehensive experiments demonstrate the superior performance of the proposed method over the state-of-the-art methods.
- 3 April 2024
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 19 (9) , 1723-1731
Incremental regression of localization context for automatic segmentation of ossified ligamentum flavum from CT data
Purpose Segmentation of ossified ligamentum flavum (OLF) plays a crucial role in developing computer-assisted, image-guided systems for decompressive thoracic laminectomy. Manual segmentation is time-consuming, tedious, and label-intensive. It also suffers from inter- and intra-observer variability. Automatic segmentation is highly desired. Methods A two-stage, localization context-aware framework is developed for automatic segmentation of ossified ligamentum flavum. In the first stage, localization heatmaps of OLFs are obtained via incremental regression. In the second stage, the obtained heatmaps are then treated as the localization context for a segmentation U-Net. Our framework can directly map a whole volumetic data to its volume-wise labels. Results We designed and conducted comprehensive experiments on datasets of 100 patients to evaluate the performance of the proposed method. Our method achieved an average Dice similarity coefficient of 61.2 ± 7.6%, an average surface distance of 1.1 ± 0.5 mm, and an average positive predictive value of 62.0 ± 12.8%. Conclusion To the best knowledge of the authors, this is the first study aiming for automatic segmentation of ossified ligamentum flavum. Results from the comprehensive experiments demonstrate the superior performance of the proposed method over the state-of-the-art methods.
- 17 March 2023
- Published by Elsevier in The Spine Journal
- Vol. 23 (8) , 1127-1136
Investigation of gait and balance function in cervical spondylotic myelopathy patients using wearable sensors
- 17 March 2023
- Published by Elsevier in The Spine Journal
- Vol. 23 (8) , 1127-1136
Investigation of gait and balance function in cervical spondylotic myelopathy patients using wearable sensors
- Open Access
- 24 August 2022
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 7 (35) , 31081-31097
Enhanced Biotribological and Anticorrosion Properties and Bioactivity of Ti6Al4V Alloys with Laser Texturing
The poor biotribological properties and bioinertness of Ti6Al4V have restricted its application in biomedical materials. In this study, microgrooves of different widths were prepared on the surface of a Ti6Al4V alloy by laser treatment. The tribological properties under dry lubrication and simulated body fluid (SBF) lubrication conditions, the electrochemical corrosion properties in SBF solution, and the bone marrow mesenchymal stem cell (BMSC) behavior on the surfaces were systematically tested. The corresponding mechanisms were discussed. The results showed that Ti6Al4V with a microgroove width of 45 μm (Ti64-45) exhibited excellent wear resistance with decreasing wear rates of 89.79 and 85.43% under dry friction and SBF lubrication compared to the Ti64 sample, which might be due to the increase of surface microhardness. Moreover, the excellent anticorrosion performance of Ti64-45 was attributed to the grain refinement on the titanium alloy surface with a lower volume fraction ratio of β phase to α phase. In addition, the microgrooves with a width of 45 μm are more conducive to BMSC proliferation and adhesion, related to promoting cell signal transduction due to cell extrusion. These studies imply that the microgroove structures are potential for application in the medical field.
- 24 August 2022
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 7 (35) , 31081-31097
Open AccessEnhanced Biotribological and Anticorrosion Properties and Bioactivity of Ti6Al4V Alloys with Laser Texturing
The poor biotribological properties and bioinertness of Ti6Al4V have restricted its application in biomedical materials. In this study, microgrooves of different widths were prepared on the surface of a Ti6Al4V alloy by laser treatment. The tribological properties under dry lubrication and simulated body fluid (SBF) lubrication conditions, the electrochemical corrosion properties in SBF solution, and the bone marrow mesenchymal stem cell (BMSC) behavior on the surfaces were systematically tested. The corresponding mechanisms were discussed. The results showed that Ti6Al4V with a microgroove width of 45 μm (Ti64-45) exhibited excellent wear resistance with decreasing wear rates of 89.79 and 85.43% under dry friction and SBF lubrication compared to the Ti64 sample, which might be due to the increase of surface microhardness. Moreover, the excellent anticorrosion performance of Ti64-45 was attributed to the grain refinement on the titanium alloy surface with a lower volume fraction ratio of β phase to α phase. In addition, the microgrooves with a width of 45 μm are more conducive to BMSC proliferation and adhesion, related to promoting cell signal transduction due to cell extrusion. These studies imply that the microgroove structures are potential for application in the medical field.
- Open Access
- 6 May 2022
- Published by Elsevier in Materials Today Bio
- Vol. 15, 100277
Immunoregulation and anti-metalloproteinase bioactive injectable polysalicylate matrixgel for efficiently treating osteoarthritis
- 6 May 2022
- Published by Elsevier in Materials Today Bio
- Vol. 15, 100277
Open AccessImmunoregulation and anti-metalloproteinase bioactive injectable polysalicylate matrixgel for efficiently treating osteoarthritis