HKHung-Ming Kuo

Hung-Ming Kuo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hung-Ming Kuo has a total of 61 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Analysis of Degradation Behaviors During Repetitive Operation Switching in Schottky GaN HEMT

    by Ya-Huan Lee, Ting-Chang Chang, Min-Chen Chen, Chien-Hung Yeh, Ting-Tzu Kuo, Jui-Tse Hsu, Jia-Hong Lin, Hung-Ming Kuo, Yu-Bo Wang, Cheng-Hsien Lin, et al.


  • Two-stage threshold voltage shift under semi-on DC stress in power p-GaN HEMTs

    by Hung-Ming Kuo, Ting-Chang Chang, Kai-Chun Chang, Ting-Tzu Kuo, Chien-Hung Yeh, Wei-Chieh Hung, Ya-Huan Lee, Jia-Hong Lin, Chun-Hung Chiang, Man-Ning Jen

    Hard-switching operation is a critical reliability concern for p-GaN high-electron-mobility transistors (HEMTs), yet degradation driven by switching transients remains insufficiently clarified. In this work, a semi-on stress, defined at the bias corresponding to the maximum switching power loss, was introduced to decouple switching-transient-induced degradation from quasi-static on-/off-state stress. Under semi-on stress, devices initially exhibit a positive threshold-voltage (Vth) shift, reduced on-state current (Ion), and suppressed gate current (Ig). Combined with a reversal of transfer characteristics hysteresis polarity after stress, these signatures indicate electron trapping in the AlGaN barrier that increases the effective injection barrier and alters the dominant gate-leakage path. In parallel, reduced off-state leakage suggests additional electron trapping in the GaN layer. Importantly, these short-term signatures vanish under source-floating semi-on stress and weaken at elevated temperature, supporting hot-carrier injection from the channel as the primary driver of early degradation. At longer stress times, however, a gradual negative shift in Vth emerges, indicating a different degradation pathway. Under high-temperature semi-on stress, a post-stress Ig increase and a negative Vth shift are observed even with a floating source, evidencing thermal-assisted hole generation and trapping in the AlGaN barrier. Comparing source-grounded and source-floating semi-on stress at high temperature, the larger negative Vth shift under source-grounded conditions further points to hole generation enhanced by self-heating during high-current operation. These results show that long-term semi-on stress is governed not only by hot-electron injection but also by thermal-assisted hole generation processes, providing a physics-based framework for assessing p-GaN HEMT reliability under realistic hard-switching operation.

  • A Method to Detect Buffer Traps by the Hysteresis Window of p-GaN HEMTs

    by Yong-Ci Zhang, Kai-Chun Chang, Po-Hsun Chen, Ting-Chang Chang, Ting-Tzu Kuo, Chien-Hung Yeh, Jia-Hong Lin, Ya-Huan Lee, Hung-Ming Kuo

    This research presents a new method for detecting GaN buffer traps in GaN high electron mobility transistors with p-type gates (p-GaN HEMTs). It is demonstrated that the hysteresis window during the transfer curve sweeping can be used to analyze the GaN buffer quality. The hysteresis behavior of p-GaN HEMTs is experimentally investigated in this research. Transfer curve sweeping with the varied ${V}_{\text {g}}$ range and gate bias stress is tested on the device to clarify the physical model of the hysteresis window in p-GaN HEMTs. A hysteresis behavioral model in p-GaN HEMTs can correlate the hysteresis window with the buffer quality, providing an effective technique for the instantaneous detection of GaN buffer quality. The method is also verified by a dynamic ${R}_{\text {on}}$ test on two devices with different buffer processes. The dynamic ${R}_{\text {on}}$ degradation has a good correlation with the hysteresis window, which indicates that this new method is effective for detecting p-GaN HEMT buffer quality. The method proposed in this study has the potential to accelerate the detection of buffer traps in p-GaN HEMT devices. Through the technology developed in this research, we can identify and address these defects more quickly, and it is expected to achieve better performance for p-GaN HEMT in the field of high-power components.


  • Analysis of Fluorine Implantation With Different Oxide Cap Thicknesses During Annealing in Contact Field Plate Lateral Double-Diffused MOS With 0.13-μm Bipolar–CMOS–DMOS Technology

    by Yu-Fa Tu, Ting-Chang Chang, Wei-Chieh Hung, Hung-Ming Kuo, Ya-Huan Lee, Yu-Hsiang Tsai

    This study thoroughly investigates the on-current ( $\text {I}_{\text {on}}\text {)}$ and nonconductive stress (NCS) reliability of the contact field plate lateral double-diffused metal–oxide–semiconductor (CFP LDMOS) with bipolar–CMOS–DMOS (BCD) technology using different fluorine (F) implantation methodologies. Two devices with different oxide cap thicknesses during annealing after F implantation are compared to a standard (STD) device without F implantation. The thin oxide cap device demonstrates the poor Si quality and defect generation after annealing, resulting in decreased $\text {I}_{\text {on}}$ as the F-imp dose increases. In contrast, the F treatment can effectively passivate defects in the thick oxide cap device, leading to improved $\text {I}_{\text {on}}$ and NCS reliability. Finally, physical mechanisms based on defect analysis, scanning electron microscope (SEM) images, and secondary ion mass spectrometer (SIMS) profiles are proposed to clarify the phenomena.

  • Analysis of the Abnormal Hot Carrier Degradation in Contact Field Plate LDMOS With Different Gate-Finger Number

    by Wei-Chieh Hung, Fu-Chen Liang, Ting-Chang Chang, Ya-Huan Lee, Hung-Ming Kuo, Yu-Hsiang Tsai, I-Yu Huang, Li-Hsin Chu, Cheng-Hsien Wu, Yu-Fa Tu

    In this study, a comparison between the performance and hot carrier degradation (HCD) of two n-type lateral double-diffused MOS (LDMOS) devices with the same active region area is made. The difference between the two devices lies in the number of poly-Si gate fingers; one is the 2-finger (Fn) configuration, while the other belongs to the 4-Fn one. Despite the similar performance of the two devices, the 4-Fn device shows more HCD. A new electron trapping model is proposed to explain the degradation of the on-state current ( ${I} _{\text {on}}$ ). Furthermore, in terms of transconductance ( ${g} _{m}$ ) peak degradation, the 4-Fn device shows a split-peak degradation phenomenon. Through COMSOL simulations of heat distribution, it is observed that the 4-Fn device experiences more thermal accumulation during hot carrier stress (HCS), with heat concentrated between the middle poly-Si gate fingers. This nonuniform heat distribution leads to varying degrees of PBTI-like degradation across the device, resulting in the observed split-peak $g_{m}$ behavior. Finally, in pulse HCS experiments, the 2-Fn and 4-Fn devices exhibit the same level of degradation, and no split-peak phenomenon in gm was observed. This is attributed to the fact that pulsing eliminates the Joule heating effect, further confirming that the degradation discrepancies between LDMOS devices with different gate finger configurations under long-term HCD result from varying degrees of positive bias temperature instability (PBTI) induction.

  • Analysis of Insulator Breakdown Induced by Body-Grounded-Coupling Effect in GaN-Based MIS-HEMT

    by Cheng-Hsien Lin, Chien-Hung Yeh, Po-Hsun Chen, Ting-Chang Chang, Ya-Huan Lee, Yu-Bo Wang, Ting-Tzu Kuo, Hung-Ming Kuo, Jui-Tse Hsu, Jia-Hong Lin, et al.

    This study focuses on abnormal breakdown issues observed during the practical operation of D-mode GaN-based metal insulator semiconductor high electron mobility transistor (MIS-HEMT). The measurement statistics show that the breakdown voltage ($\textit{V}_{\text{BD}}\text{)}$ of the body-floating device reaches 1653 V; however, the body-grounded device experiences early breakdown at 1161 V. Through high-temperature reverse bias (HTRBs) degradation mechanisms, a discrepancy in the energy band of the channel layer due to body contact is identified. The experimental results indicate that the phenomenon corresponds to drain-induced barrier lowering (DIBL), causing the channel to turn on early. TCAD simulations indicate that the body-grounded state causes larger energy band bending and generates a higher electric field within the insulator compared to the body-floating state, which is called the body-grounded coupling effect. Furthermore, the gate and drain lag dynamic measurement confirms that the effect originates from the buffer, while the electric field beneath the gate does not immediately affect the quality of the dielectric layer. This mechanism of this study is proposed to describe the insulator breakdown behavior that occurs in the D-mode body-grounded MIS-HEMTs.


  • Analysis of the Formation of the Off-State Leakage Current in p-GaN HEMT

    by Ya-Huan Lee, Po-Hsun Chen, Yu-Hsuan Yeh, Jui-Tse Hsu, Wei-Chieh Hung, Jia-Hong Lin, Hung-Ming Kuo, Han-Yu Chang, Cheng-Hsien Lin, Yu-Jie Tsai, et al.

    In this study, the off-state leakage current ( ${I} _{\text {off}}$ ) of p-GaN high electron mobility transistor (HEMT) is analyzed. At low drain bias approximately below 100 V, the leakage is dominated by the punchthrough leakage current from the source electrode, resulting in an increase in ${I} _{\text {off}}$ as the bias increases. However, at an intermediate drain bias to 400 V, the punchthrough leakage current will decrease because of the gate electron injection. The electrons will be injected into the GaN buffer layer, indirectly leading to a decrease in ${I} _{\text {off}}$ . Lastly, at a higher drain bias of 700 V, the dominant leakage path is converted into the body current, which is dominated by the trap-assisted thermionic field emission (TA-TFE) mechanism. The generated holes will recombine with the injected electrons or inject into the buffer layer, leading to a significant increase in ${I} _{\text {off}}$ . The reliability testing is also employed to validate the underlying mechanisms.


  • The Reliability and Noise Investigation of Boron Diffusion Under Positive Bias Temperature Instability in 16 nm Node High Voltage FinFETs

    by Ting-Tzu Kuo, Ying-Chung Chen, Ting-Chang Chang, Chien-Hung Yeh, Jia-Hong Lin, Ya-Huan Lee, Wei-Chieh Hung, Hung-Ming Kuo, Jui-Tse Hsu, Cheng-Hsien Lin, et al.

    This work investigates the impact of boron diffusion under positive bias temperature instability (PBTI) for 16 nm node FinFET high-voltage applications. Boron doped in the extended source/drain region can improve the tolerance of hot carrier stress (HCS). However, boron diffusing into the channel could worsen the interface quality. The shallow defects originating from the diffusive boron would influence the behavior of low-frequency noise (LFN), which is, as a result, unfavorable in terms of CMOS image sensor applications. Therefore, the analysis of the defect behavior is necessary. In this work, a comprehensive inspection including PBTI and LFN is carried out. Boron diffusion may generate shallow interface traps and reflect in PBTI degradation and power spectrum density. At the same time, an abnormal channel length PBTI degradation trend is observed between STD and B/F devices. A complete PBTI model is proposed to figure out the mechanisms. Hence, for high-voltage applications, the investigation may make a better understanding of the impact of defects and suggest solutions.

  • An Approach to Extract the Trap States via the Dynamic Ron Method With Substrate Voltage Applied During the Recovery Time

    by Ya-Huan Lee, Po-Hsun Chen, Yong-Ci Zhang, Chung-Wei Wu, Sheng-Yao Chou, Yu-Bo Wang, Hung-Ming Kuo, Yu-Shan Lin, Yan-Ta Chen, Yu-Jie Tsai, et al.

    This study discusses the application of the substrate voltage during the recovery time with the dynamic on-resistance (dynamic ${R}_{\text {on}}$ ) method to extract the deep trap states in the buffer layer after the hard-switching stress in p-GaN high electron mobility transistors (p-GaN HEMTs). This method will be more suitable for the detection of the deep trap states where the carriers are difficult to de-trap in the buffer layer. Then, a hard switching stress condition is applied to the device and the degradation is caused by the mechanism of the hot electron effect and the impact ionization. The generated electrons and holes will trap into the buffer layer in the drift region at the gate edge near the drain side and the AlGaN layer under the gate, respectively. Moreover, through the novel of the dynamic ${R}_{\text {on}}$ method with the substrate voltage applied, the deep trap states in the buffer can be extracted.


  • An Extensive Negative Gate Bias Stress Degradation Mechanism in GaN MIS-HEMTs for Aerospace Applications

    by Ting-Tzu Kuo, Ying-Chung Chen, Ting-Chang Chang, Jia-Hong Lin, Kai-Chun Chang, Jui-Tse Hsu, Yi-Zhen Wu, Chien-Hung Yeh, Wei-Chieh Hung, Ya-Huan Lee, et al.

    In recent years, GaN HEMT has become one of the most ideal devices for its low ON-state resistance and high breakdown voltage. Compared with other HEMT structures, GaN MIS HEMT is recognized as one of the most attractive candidates to replace silicon-based high-power devices in the aerospace industry because of their excellent temperature tolerance. Therefore, this study investigates how a wide temperature range of 77–393 K influences the degradation mechanism of negative gate bias stress (NGBS) in GaN MIS-HEMTs. The threshold voltage shift for GaN MIS-HEMTs’ NGBS is very distinctive both under cryogenic temperature and high temperature. Typically, as the temperature rises from 77 to 303 K, the positive shift of threshold voltage also increases due to electron trapping in the Si $_{\text{3}}$ N $_{\text{4}}$ bulk layer and at the Si $_{\text{3}}$ N $_{\text{4}}$ /AlGaN interface. However, from 303 to 393 K, the opposite behavior of the threshold voltage shift is observed due to additional hole trapping in Si $_{\text{3}}$ N $_{\text{4}}$ from ionization impact, which can be verified from its stress data in Silvaco TCAD simulation and its recovery duration as well. In addition, a thicker Si $_{\text{3}}$ N $_{\text{4}}$ layer device is produced to clarify the NGBS model. Thus, this study proposes an extensive NGBS model from 77 to 393 K to verify the abnormal degradation phenomenon in GaN MIS-HEMTs.