ABAmr Mohamed Beltagi

Amr Mohamed Beltagi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Amr Mohamed Beltagi has a total of 36 co-authors. Here are the top co-authors by number of shared publications:

  • Enass M. Ghoneim

    Faculty of Science, Chemistry Department, Analytical & Electrochemistry Research Unit , Tanta University , 31527 – Tanta, Egypt

    2 shared publications
  • Mohammed M. Ghoneim

    Department of Pharmacy Practice, College of Pharmacy, AlMaarefa University, Ad Diriyah, Riyadh 13713, Saudi Arabia; Research Center, Deanship of Scientific Research and Post-Graduate Studies, AlMaarefa University, Diriyah, 13713 Riyadh, Saudi Arabia

    2 shared publications
  • A. A. Hathoot

    Electrochemistry Laboratory, Chemistry Department, Faculty of Science, Menoufia University, Shebin El-Kom 32511, Egypt

    1 shared publication
  • A. E. Ayad

    Chemistry Department, Faculty of Science, Kafrelsheikh University, Kafrelsheikh, Egypt

    1 shared publication
  • A. I. Ali

    Chemistry Department, Faculty of Science, Benha University, Benha, Egypt

    1 shared publication
  • A. Y. El-Etre

    Chemistry Department, Faculty of Science, Benha University, Benha, Egypt

    1 shared publication

Latest Publications

  • Open Access

    Mechanistic insights into methylene blue biodegradation by Tetradesmus obliquus: a multimodal approach using absorption, fluorescence, and square wave voltammetry

    by Merehan A. Talha, Hamdy E. Agwa, Amr M. Beltagi, Eithar El-Mohsnawy, Awatif S. Ali

    Industrial dye wastewater production has surged alongside rapid industrial growth. This study evaluates the biodegradation of methylene blue (MB) by Tetradesmus obliquus, utilizing spectroscopical and electrochemical techniques to monitor effectiveness. Biodegradation model reveals conditions and pathways involved. Tetradesmus obliquus exhibits robust dye degradation, reducing absorbance at 664 nm significantly within days. MB concentrations of 2–4 mg/L were nearly completely degraded by day 6 and fully by day 9, with higher concentrations gradually reduced over 14 days. Square wave voltammetry showed full degradation of 0.2 mg/L MB by day 9. Fluorescence spectral analysis highlighted red-shifted emissions and decreased intensity due to MB presence. Growth patterns indicate Tetradesmus obliquus thrives post-MB adsorption, producing extracellular superoxide and hydrogen peroxide that convert MB to CO2, NO2, and H2O. Spectroscopic and electrochemical data confirm MB breakdown while boosting algal growth. This study demonstrates Tetradesmus obliquus’s efficacy in biodegrading MB from industrial textile wastewater, removing residual dye-bath additives and promoting environmental sustainability.


  • Open Access

    GSH/pH-Responsive Chitosan–PLA Hybrid Nanosystems for Targeted Ledipasvir Delivery to HepG2 Cells: Controlled Release, Improved Selectivity, DNA Interaction, Electrochemical and Stopped-Flow Kinetics Analyses

    by Ahmed M. Albasiony, Amr M. Beltagi, Mohamed M. Ibrahim, Shaban Y. Shaban, Rudi van Eldik

    This study aimed to design dual-responsive chitosan–polylactic acid nanosystems (PLA@CS NPs) for controlled and targeted ledipasvir (LED) delivery to HepG2 liver cancer cells, thereby reducing the systemic toxicity and improving the therapeutic selectivity. Two formulations were developed utilizing ionotropic gelation and w/o/w emulsion techniques: LED@CS NPs with a size of 143 nm, a zeta potential of +43.5 mV, and a loading capacity of 44.1%, and LED-PLA@CS NPs measuring 394 nm, with a zeta potential of +33.3 mV and a loading capacity of 89.3%, with the latter demonstrating significant drug payload capacity. Since most drugs work through interaction with DNA, the in vitro affinity of DNA to LED and its encapsulated forms was assessed using stopped-flow and other approaches. They bind through multi-modal electrostatic and intercalative modes via two reversible processes: a fast complexation followed by a slow isomerization. The overall binding activation parameters for LED (cordination affinity, Ka = 128.4 M−1, Kd = 7.8 × 10−3 M, ΔG = −12.02 kJ mol−1), LED@CS NPs (Ka = 2131 M−1, Kd = 0.47 × 10−3 M, ΔG = −18.98 kJ mol−1) and LED-PLA@CS NPs (Ka = 22026 M−1, Kd = 0.045 × 10−3 M, ΔG = −24.79 kJ mol−1) were obtained with a reactivity ratio of 1/16/170 (LED/LED@CS NPs/LED-PLA@CS NPs). This indicates that encapsulation enhanced the interaction between the DNA and the LED-loaded nanoparticle systems, without changing the mechanism, and formed thermodynamically stable complexes. The drug release kinetics were assessed under tumor-mimetic conditions (pH 5.5, 10 mM GSH) and physiological settings (pH 7.4, 2 μM GSH). The LED@CS NPs and LED-PLA@CS NPs exhibited drug release rates of 88.0% and 73%, respectively, under dual stimuli over 50 h, exceeding the release rates observed under physiological conditions, which were 58% and 54%, thereby indicating that the LED@CS NPs and LED-PLA@CS NPs systems specifically target malignant tissue. Release regulated by Fickian diffusion facilitates tumor-specific payload delivery. Although encapsulation did not enhance the immediate cytotoxicity compared to free LED, as demonstrated by an in vitro cytotoxicity in HepG2 cancer cell lines, it significantly enhanced the therapeutic index (2.1-fold for LED-PLA@CS NPs) by protecting non-cancerous cells. Additionally, the nanoparticles demonstrated broad-spectrum antibacterial effects, suggesting efficacy in the prevention of chemotherapy-related infections. The dual-responsive LED-PLA@CS NPs allowed controlled tumor-targeted LED delivery with better selectivity and lower off-target toxicity, making LED-PLA@CS NPs interesting candidates for repurposing HCV treatments into safer cancer nanomedicines. Furthermore, this thorough analysis offers useful reference information for comprehending the interaction between drugs and DNA.


  • Stripping Voltammetric Determination of the Antiviral Drug Ribavirin in Pharmaceutical Formulations and Human Serum

    by Amr M. Beltagi, Gamal K. Gomaa, Aya R. Elgaml

    A highly sensitive square-wave adsorptive anodic stripping voltammetric method is described for the determination of ribavirin in its pharmaceutical formulations and human blood serum, utilizing a carbon paste electrode. The peak current was significantly enhanced due to the strong adsorptive properties of the drug at the electrode surface. The optimal procedural parameters were: frequency of 20 Hz, scan increment of 4 mV, pulse amplitude of 25 mV, and accumulation potential of –0.5 V versus Ag/AgCl/3 M KCl in Britton–Robinson buffer at pH 8.0. The described method was successfully applied for the assay of ribavirin in its pharmaceutical formulation (Ribavirin® capsules, 200 mg ribavirin), with mean percentage recoveries of (98.3 ± 1.3)%. Furthermore, the method was successfully applied for the assay of ribavirin in spiked human blood serum without the necessity for sample pretreatment or time-consuming extraction prior to analysis. The mean percentage recovery of ribavirin in human blood serum was (98.6 ± 1.1)% (n = 5), with a limit of detection of 1 × 10–9 M (0.24 ng/mL). Due to this extremely low limit of detection, the proposed method can be applied in pharmacokinetic and pharmacodynamic studies of the drug.

  • Free-silicic Acid Impedimetric Quantification of Orthophosphate in Seawater

    by Mahmoud Fatehy Altahan, Amr Mohamed Beltagi, Magdi Abdel-Azzem, Mona A. El-Attar

    In this study, we present a modified electrode, specifically the molybdate/carbon paste electrode (CPE), for the determination of orthophosphate in seawater. The molybdate/CPE modified electrode was successfully utilized for electrochemical impedance spectroscopy of orthophosphate in a highly acidic medium with a pH of 0.8. Within the concentration range of 0.01 to 2 μM, the molybdate/CPE electrode demonstrated a very low limit of determination of 2.8 × 10−6 μM. To assess precision, concentrations of 0.02 and 0.1 μM were chosen, resulting in relative standard deviations of 3.93% and 4.11%, respectively. One potential interfering ion, silicic acid, was investigated for its influence on the reaction between molybdate ions and phosphate. Surprisingly, the presence of silicic acid did not affect the linearity of phosphate determination. Additionally, the repeatability of phosphate determination remained largely unaffected by the addition of different concentrations of silicic acid. This was confirmed through scanning electron microscopy and energy dispersive X-ray analysis, which revealed no detectable silicon atoms on the electrode surface during the phosphate determination in the presence of silicic acid. Furthermore, a comparison was made between our method and the classical spectrophotometric assay. Our method exhibited good recovery values, further validating its effectiveness in orthophosphate determination.


  • Fabrication of an Economic Electrochemical Sensor Based on Cobalt Oxide Nanoparticles for Determination of Flufenamic Acid

    by A. E. Ayad, I. El-Mehasseb, G. K. Gomaa, A. M. Beltagi

    An electrochemical sensor for anti-inflammatory drug flufenamic acid, based on cobalt oxide (Co3O4) modified carbon paste electrode (CPE), has been fabricated. Co3O4 NPs was synthesized and characterized by UV-visible spectrophotometry, Fourier transform infrared (FT-IR) spectroscopy, X-ray diffraction (XRD), scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The novel 0.5%(w/w)Co3O4/CPE sensor was also evauatedusing the cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). It showed a much-enhanced electroactive surface area and low charge transfer resistance (Rct), revealing that it has greatly enhance electron transfer process. Square wave voltammetry (SWV) was utilized as a sensitive method for the determination of very low concentrations of flufenamic acid. Under the optimized conditions, the limits of detection (LOD) and quantification (LOQ) of 0.5%Co3O4(w/w)/CPE were 4.8×10–9 M (1.35 ng/mL) and 1.6×10–8 M (4.50 ng/mL), respectively. After validation of the fabricated sensor, it was successfully applied for sensitive and selective determination of the drug in spiked human serum with LOD and LOQ of 4.5×10–8 M (12.65 ng/mL) and 1.5×10–7 M (42.18 ng/mL).


  • Development of a Disposable Pencil Graphite Electrode Modified with Poly 1,5-Diaminonaphthalene for Voltammetric Determination of Flufenamic Acid

    by N. M. Omar, E. M. Mabrouk, A. Y. El-Etre, A. I. Ali, A. M. Beltagi

    Due to their comparable electrical properties, pencil graphite electrodes (PGE) have become a more popular electrode in electrochemical applications than traditional carbon electrodes, mostly because of their affordability and availability, which allows for disposable applications. Both cyclic voltammetry (CV) and chronoamperometry (CA) techniques were used to develop a new disposable modified pencil graphite electrode based on the electropolymerization of 1,5-diaminonaphthalane (1,5-DAN). Characterization results confirmed that the modified p-1,5-DAN/PGE(CV) sensor showed much enhanced sensitivity and lower resistivity than the bare and p-1,5-DAN/PGE(CA) sensor, therefore, it was used for the sensitive and selective voltammetric determination of flufenamic acid (FFA). Under the optimum experimental conditions, the p-1,5-DAN/PGE(CV) sensor showed limits of detection (LOD) and quantitation (LOQ) of 4.97 × 10−10 (0.14 ng ml−1) and 1.66 × 10−9 M (0.47 ng ml−1), respectively, applying square wave anodic stripping voltammetry method. The p-1,5-DAN/PGE(CV) sensor also exhibits good accuracy, repeatability, storage stability and selectivity for detecting FFA in biological fluids. These results confirms that the developed p-1,5-DAN/PGE(CV) sensor is more sensitive to measuring FFA in biological fluids, pharmaceutical formulations, and pharmacokinetic studies compared with the previous electrochemical sensors.


  • Open Access

    Simultaneous voltammetric sensing of Zn2+, Cd2+, and Pb2+using an electrodeposited Bi–Sb nanocomposite modified carbon paste electrode

    by E. A. Shalaby, A. M. Beltagi, A. A. Hathoot, M. Abdel Azzem

    A highly sensitive sensor. A sensor for detecting Zn2+, Cd2+, and Pb2+ions simultaneously based on the square wave anodic stripping response at a bismuth antimony (Bi–Sb) nanocomposite electrode was developed.


  • Simultaneous determination of cadmium (II), lead (II), copper (II) and mercury (II) by square-wave anodic stripping voltammetry at a montmorillonite-calcium modified carbon paste electrode

    by Amr M. Beltagi, Enass M. Ghoneim, Mohamed M. Ghoneim

    A simple and efficient montmorillonite-calcium modified carbon paste electrode (MMT-Ca modified CPE) was constructed for simultaneous trace determination of Cd(II), Pb(II), Cu(II) and Hg(II). The MMT-Ca modified CPE significantly enhances the voltammetric stripping peak current magnitudes of the investigated metal ions compared to the bare CPE due to the large cation-exchange capacity and the strong adsorptive property of montmorillonite-Ca clay. A fully validated simple, sensitive, selective and precise square-wave anodic stripping voltammetric method was developed for the simultaneous trace determination of Cd(II), Pb(II), Cu(II) and Hg(II) in various water samples using a fabricated 10% (w/w) MMT-Ca modified CPE. The achieved limits of detection of Cd(II) 0.54 µg L−1, Pb(II) 0.30 µg L−1, Cu(II) 0.75 µg L−1 and Hg(II) 1.05 µg L−1 indicating the high sensitivity of the described SW-AS voltammetry method for the assay of these metal ions in aqueous solutions. The method was successfully applied for analysis of tap water, bottled natural water and seawater samples.