Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yongjoo Kim has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    An Evaluation of the Fire Safety of Waste Paper-Based Internal Finishing Materials Combined with Expandable Graphite According to Changes in Magnesium Hydroxide Content

    by Dongin Park, Yongjoo Kim, Dongho Rie

    Inflammable building finishing materials act as a major cause of fire propagation, and they, therefore, pose significant risks to life and can lead to property damage. To replace such flammable building finishing materials, many countries have established regulations limiting their use, which has led to extensive research on the development of flame-retardant building finishing materials. Such methods have included adding flame retardants to construction materials to reduce the heat release rate and total heat release. The present study aimed to enhance the fire performance of cellulose-based architectural finishing materials by creating a dual flame-retardant mixture using expandable graphite and magnesium hydroxide added to recycled paper waste. Specimen fabrication involves using a pressing method to apply uniform pressure to compress the mixture in a mold. The total heat release (THR), CO, and CO2 production of the produced specimens were measured using a cone calorimeter while varying the magnesium hydroxide additive ratio. The combustion gases were measured through NES 713 experiments to determine any changes in the Toxic Index corresponding to variations in the magnesium hydroxide content. The experiment results established a correlation between the magnesium hydroxide additive ratio and the total heat release, as well as the existence of variations in CO and CO2 production for the dual flame-retardant recycled paper material. A database for combustion gases was also obtained. It was confirmed that the fire performance was improved by confirming that the total heat release decreased by 52% from the previous one in the magnesium hydroxide content of 30 g, and it was confirmed that the inflection points of the Toxic Index value due to the change in CO and CO2 gas production occurred in the magnesium hydroxide content of 20 g due to the improvement of the fire performance. Through the ISO 5660-1 experiment data, we have secured data that can be used as foundational information for performance-oriented fire risk assessments, thereby ensuring the fire safety of cellulose materials that are vulnerable to fire.


  • Open Access

    Evaluation of the Fire Impact of Cellulose-Based Indoor Building Finishing Materials According to Changes in Room Size Aspect Ratio

    by Yongjoo Kim, Dongho Rie

    In modern society, the size of buildings tends to expand due to technological advances. However, while prioritizing performance design and specific building materials, fire research has fallen short of creating a comprehensive fire characteristic database for building materials. This study presents a plan for building a big data resource to evaluate the fire performance of cellulose-based flame retardant building finishing material in buildings of varying sizes. The three types of building finishing materials applied in this study are polyurethane foam, MDF, and cellulose-based building finishing materials. The variables were determined based on the floor area, and the change in floor area was calculated using the aspect ratio, a dimensionless number. Data analysis utilized the Fire Dynamics Simulator (FDS) to determine the time required to meet life safety standards for temperature, visibility, and Fractional Effective Dose (FED). The results confirm a correlation between the safe evacuation time (ASET) and increasing floor area. Additionally, the study demonstrates that cellulose-based flame-retardant building finishing material effectively maintains safe evacuation times even with increasing floor areas, as evidenced by increases of 41.0 s, 13.2 s, and 97.5 s in temperature, visibility, and FED, respectively.

  • Open Access

    A Study on Nursing Personnel Operations to Ensure Evacuation Safety during Medical Facility Disasters

    by Yongjoo Kim, Junghyeon Kim, Moonsik Kim, Dongho Rie

    Worldwide, the number of users of medical facilities is increasing due to the pandemic phenomenon and extended life expectancy. In addition, the majority of medical facility occupants are patients, leading to issues of inconvenience in movement and increased vulnerability during evacuations in the event of a fire. Therefore, the availability of nursing personnel, who serve as assistants in tasks such as transporting beds and wheelchairs essential for patient evacuation, is crucial for ensuring evacuation safety. However, a global shortage of nursing personnel has led to ongoing research on optimizing workforce allocation. In this study, the Available Safe Egress Time (ASET) and Required Safe Egress Time (RSET) were quantitatively compared for medical facilities with a combination of intensive care units and general wards, utilizing a Fire Dynamics Simulator (FDS) and Flexsim Healthcare simulations to assess fire risk. The research goal here is to provide sustainable research directions for determining the minimum ratio of nurses to patients required for evacuation in a disaster, ensuring the continuous availability of nursing personnel in medical facilities. To achieve this, the variable was set to five stages based on the total number of patients per nurse. As a result of this study, it was confirmed that when the nurse-to-patient ratio exceeded 1:6, more than 70% of bedridden patients died. Additionally, it was verified that maintaining a patient-to-nurse ratio of less than 1:1 is effective for ensuring evacuation safety.


  • Open Access

    Fire performance, toxicity, and thermal diffusivity of wastepaper mixed with magnesium hydroxide, depending on the particle size of expandable graphite

    by Chansol Ahn, Dongin Park, Yongjoo Kim, Dongho Rie

    As the construction of high-rise buildings increases to solve residential spaces caused by high density population concentration, the occurrence of fire accidents in high-rise buildings is also increasing. The primary cause of fire damage in high-rise buildings is the spread of fire caused by exterior wall finishes. Therefore, it is essential to develop semi-non-combustible finishes that can be applied to high-rise buildings to prevent the spread of fire due to exterior wall finishes. To address this issue, numerous studies are being conducted to develop flame retardant finishing materials that reduce heat release rate and total heat release. A double flame retardant mixed waste paper with expandable graphite and magnesium hydroxide was manufactured to improve the fire performance of cellulose building finishing materials. Total heat release (THR), CO, and CO2 Generation changes were measured using a cone calorimeter, and thermal diffusion rate was measured through the LFA 1000 experiment. The correlation of total heat release, CO generation, CO2 generation, and mass reduction rate by variation of expandable graphite's mesh size at double flame-retardant waste paper were secured through a cone calorimeter test. The thermal diffusion rate data of the specimen were secured through the LFA 1000 experiment. Through experiments, it has been confirmed that specimens using specific expandable graphite particles can be utilized as fire-resistant finishing materials in construction, ensuring fire resistance performance.


  • Open Access

    A Study on the Quantitative Fire Performance Evaluation Method of Building Finishing Materials with a Focus on Medical Facilities

    by Yongjoo Kim, Dongin Park, Soobin Kim, Dongho Rie

    Buildings in modern society tend to gradually expand in size due to technological development and overcrowding, which increases the risk of fire. Therefore, continuous efforts are being made to ensure the evacuation safety of occupants by installing firefighting facilities and using flame retardant building finishing materials. This study aims to present a fire performance evaluation plan for building finishing materials using simulations and identify risks that arise from not using flame retardant building finishing materials in medical facilities with vulnerable occupants. A control group for fire performance evaluation was selected using polyurethane foam, while two types of cellulose-based building finishing materials with different flame retardants were chosen for analysis. The cellulose-based finishing materials included expanded graphite, magnesium hydroxide, montmorillonite, and ammonium polyphosphate. Fire performance was evaluated using FDS and path detector simulations based on NES 713 and ISO 5660-1. The results of the study showed that there was a difference of three people in the prediction of the number of deaths depending on the scope of analysis, and it was confirmed that the toxic gas detected was different depending on the added flame retardant. Additionally, construction finishing materials with flame retardant performance increased ASET by at least 130 s compared to polyurethane foam, and the evacuation safety exceeded 1, confirming the effectiveness of securing evacuation stability for occupants.


  • Open Access

    Evaluation of the Flame-Retardant Performance and Fire Risk of Cellulose Building Finishing Material Due to the Particle Size of Expandable Graphite

    by Yongjoo Kim, Dongin Park, Dongho Rie

    The burning of building finishing materials containing chemical substances can lead to the spread of fire with a large number of harmful substances. To prevent this, cellulose, an eco-friendly material that minimizes the generation of harmful substances, was chosen as the main material for building finishing materials. Wastepaper was recycled to extract cellulose, and a finishing material was manufactured by mixing in expandable graphite and magnesium hydroxide. The flame-retardant performance of the finishing material was evaluated by measuring the total heat emission rate using the ISO 5660-1 cone calorimeter, with the particle size of the expanded graphite as a variable. The measured physical properties value was used as the FDS parameter to evaluate the risk of fire. Results show that the cellulose-based building finishing material meets the life safety standard of NFSC 203 during the simulation time and has a FED value that does not exceed 0.001 at maximum. This confirms its effectiveness in providing safe egress time for residents.