Hongtao Fan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hongtao Fan has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Yaojie Sun
College of Intelligent Robotics and Advanced Manufacturing, Fudan University, Shanghai 200438, China
5 shared publications Shiyi Fu
4 shared publications- Yu Wang
Fudan University
3 shared publications - Kun He
School of Intelligent Robotics and Advanced Manufacturing, Fudan University, Shanghai, 200433, People’s Republic of China
2 shared publications Ruixiang Zhang
2 shared publications- Shuyu Yuan
Hainan University
2 shared publications
Latest Publications
- 8 December 2025
- Published by Elsevier in Applied Energy
- Vol. 405
Adaptive optimization algorithms for scheduling multiple battery energy storage systems in complex grid scenarios
- 8 December 2025
- Published by Elsevier in Applied Energy
- Vol. 405
Adaptive optimization algorithms for scheduling multiple battery energy storage systems in complex grid scenarios
- 25 September 2025
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 226
Recent progress in state of health estimation for lithium-ion batteries: From laboratory to practical application
- 25 September 2025
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 226
Recent progress in state of health estimation for lithium-ion batteries: From laboratory to practical application
- 11 July 2025
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 172 (7)
Revealing the Unique Influential Mechanism of Parallel-connected Lithium-ion Cells Based on Current Distribution: The Vectorial Effect among Cell-to-cell Parameters
With the growing demand for electric power energy, large-scale energy storage systems increasingly adopt the parallel connection of lithium-ion batteries to ensure capacity scalability. However, battery grouping in practice inevitably encounters cell-level parameter evolution, leading to variations in internal resistance and capacity due to manufacturing inconsistencies and operational aging. Conventional designs enforce strict uniformity, raising costs and limiting flexibility. This study investigates the impact of parameter inconsistency on the performance of parallel-connected lithium-ion cells. A simulation framework based on a modified Shepherd model—integrating Equivalent Circuit and Electrochemical Models—is developed to quantify Capacity Utilization Efficiency Loss (CUEL) under different discharge rates. Results indicate that resistance deviation (ΔR) predominantly affects CUEL at low rates, whereas capacity deviation (ΔC) plays a larger role at higher rates. Importantly, a vectorial effect emerges, wherein the combined influence of ΔR and ΔC may either amplify or offset CUEL depending on their directional alignment. This effect reveals exploitable interactions among cell variations. Experimental validation confirms the model's predictive capacity, suggesting that moderate parameter diversity may be strategically utilized. While long-term aging effects require further study, the findings offer a more economical and adaptable strategy for battery grouping and parallel connection designs.
- 11 July 2025
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 172 (7)
Revealing the Unique Influential Mechanism of Parallel-connected Lithium-ion Cells Based on Current Distribution: The Vectorial Effect among Cell-to-cell Parameters
With the growing demand for electric power energy, large-scale energy storage systems increasingly adopt the parallel connection of lithium-ion batteries to ensure capacity scalability. However, battery grouping in practice inevitably encounters cell-level parameter evolution, leading to variations in internal resistance and capacity due to manufacturing inconsistencies and operational aging. Conventional designs enforce strict uniformity, raising costs and limiting flexibility. This study investigates the impact of parameter inconsistency on the performance of parallel-connected lithium-ion cells. A simulation framework based on a modified Shepherd model—integrating Equivalent Circuit and Electrochemical Models—is developed to quantify Capacity Utilization Efficiency Loss (CUEL) under different discharge rates. Results indicate that resistance deviation (ΔR) predominantly affects CUEL at low rates, whereas capacity deviation (ΔC) plays a larger role at higher rates. Importantly, a vectorial effect emerges, wherein the combined influence of ΔR and ΔC may either amplify or offset CUEL depending on their directional alignment. This effect reveals exploitable interactions among cell variations. Experimental validation confirms the model's predictive capacity, suggesting that moderate parameter diversity may be strategically utilized. While long-term aging effects require further study, the findings offer a more economical and adaptable strategy for battery grouping and parallel connection designs.
- 16 December 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 99
A user-centric temperature sensor deployment method under digital twin leveraging occupancy information
- 16 December 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 99
A user-centric temperature sensor deployment method under digital twin leveraging occupancy information
- Open Access
- 10 May 2023
- Published by Elsevier in Applied Energy
- Vol. 343
An improved multi-timescale coordinated control strategy for an integrated energy system with a hybrid energy storage system
- 10 May 2023
- Published by Elsevier in Applied Energy
- Vol. 343
Open AccessAn improved multi-timescale coordinated control strategy for an integrated energy system with a hybrid energy storage system
- 1 March 2023
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 170 (3) , 030514
A Novel Quick Screening Method for the Second Usage of Parallel-connected Lithium-ion Cells Based on the Current Distribution
Battery screening is the key segment of secondary applications. The benchmark for conventional methods is mainly based on the series connection and makes parameter difference as the screening index a gold standard. However, because of self-balancing current in parallel connection, the existence of a certain degree of parameter difference is allowed and parameter difference may not be the best option, which leads to lower screening efficiency due to the higher uniform of parameters. This work firstly identifies the boundary of parameter difference and provides the ideal working point (IWP), which is related to maximum capacity utilization efficiency, as a novel screening index for parallel connection derived from the current distribution. A modified shepherd model is employed to calculate the IWPs and is verified that the maximum dynamic error is below 1.1%. Therefore, it is quick to achieve screening by judging whether the IWP falls within the normal working range. The results show that the maximum capacity utilization efficiency always occurs at the load current close to the IWP, which verifies the validity of IWP. Compared with the conventional method, the proposed method is validated based on a case study to improve screening efficiency and provides different ideas for flexible grouping.
- 1 March 2023
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 170 (3) , 030514
A Novel Quick Screening Method for the Second Usage of Parallel-connected Lithium-ion Cells Based on the Current Distribution
Battery screening is the key segment of secondary applications. The benchmark for conventional methods is mainly based on the series connection and makes parameter difference as the screening index a gold standard. However, because of self-balancing current in parallel connection, the existence of a certain degree of parameter difference is allowed and parameter difference may not be the best option, which leads to lower screening efficiency due to the higher uniform of parameters. This work firstly identifies the boundary of parameter difference and provides the ideal working point (IWP), which is related to maximum capacity utilization efficiency, as a novel screening index for parallel connection derived from the current distribution. A modified shepherd model is employed to calculate the IWPs and is verified that the maximum dynamic error is below 1.1%. Therefore, it is quick to achieve screening by judging whether the IWP falls within the normal working range. The results show that the maximum capacity utilization efficiency always occurs at the load current close to the IWP, which verifies the validity of IWP. Compared with the conventional method, the proposed method is validated based on a case study to improve screening efficiency and provides different ideas for flexible grouping.