Shimin Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shimin Yu has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Qi Yan
State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan, China
3 shared publications - Yufeng Zhang
The State Key Laboratory Breeding Base of Basic Science of Stomatology (Hubei-MOST) & Key Laboratory of Oral Biomedicine Ministry of Education, School & Hospital of Stomatology, Wuhan University, Wuhan 430079, China
3 shared publications - Yulan Wang
State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology Wuhan University Wuhan China
3 shared publications - Yunxiao Wang
State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan 430079, China
3 shared publications - Richard J. Miron
Department of Periodontology University of Bern Bern Switzerland
2 shared publications - Yi Feng
Department of Oral Implantology, School & Hospital of Stomatology, Wuhan University, Wuhan, China
2 shared publications
Latest Publications
- 12 September 2024
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 26 (6) , 1270-1278
A transcrestal sinus floor elevation strategy based on a haptic robot system: An in vitro study
Objectives: To reveal the force profiles recorded by haptic autonomous robotic force feedback during the transcrestal sinus floor elevation (TSFE) process, providing a reference for the surgery strategy during TSFE.Materials and methods: A total of 42 maxillary sinus models with different angles of the sinus floor (30°, 40°, 50°, 60°, 70°, 80°, and 90°, compared to vertical plane) were 3D printed. Implant site preparation was performed using a robotic system, and the total force (Ft) and axial force along the drill (Fz) during the surgery were recorded by the haptic robotic arm. The actual initial breakthrough point (drill contacting sinus floor) and complete breakthrough point (drill penetrating the sinus floor) were defined visually (the actual IBP and the actual CBP). The theoretical initial breakthrough point (the theoretical IBP) and the theoretical complete breakthrough point (the theoretical CBP) defined by the robot‐guided system and the CBCT were determined by real‐time force feedback and imaging distance measurement, respectively. The distance from the bottom of the resin model to the actual IBP and the actual CBP was defined as Di and Dt, respectively.Results: The difference in Fz began to increase significantly at 70°, while the difference in Ft became significant at 60°. When the angle was greater than 70°, there was no significant difference in the discrepancy between the actual and theoretical perforation points. Compared to judging the breakthrough point by CBCT, real‐time force feedback TSFE under robotic surgery achieved more accurate initial breakthrough point detection.Conclusions: The smaller the angle, the larger the breakthrough force for the drill. The real‐time force feedback of haptic robotic system during TSFE could provide reliable reference for dentists. More clinical studies are needed to further validate the application of robotic surgery assisted TSFE.
- 12 September 2024
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 26 (6) , 1270-1278
A transcrestal sinus floor elevation strategy based on a haptic robot system: An in vitro study
Objectives: To reveal the force profiles recorded by haptic autonomous robotic force feedback during the transcrestal sinus floor elevation (TSFE) process, providing a reference for the surgery strategy during TSFE.Materials and methods: A total of 42 maxillary sinus models with different angles of the sinus floor (30°, 40°, 50°, 60°, 70°, 80°, and 90°, compared to vertical plane) were 3D printed. Implant site preparation was performed using a robotic system, and the total force (Ft) and axial force along the drill (Fz) during the surgery were recorded by the haptic robotic arm. The actual initial breakthrough point (drill contacting sinus floor) and complete breakthrough point (drill penetrating the sinus floor) were defined visually (the actual IBP and the actual CBP). The theoretical initial breakthrough point (the theoretical IBP) and the theoretical complete breakthrough point (the theoretical CBP) defined by the robot‐guided system and the CBCT were determined by real‐time force feedback and imaging distance measurement, respectively. The distance from the bottom of the resin model to the actual IBP and the actual CBP was defined as Di and Dt, respectively.Results: The difference in Fz began to increase significantly at 70°, while the difference in Ft became significant at 60°. When the angle was greater than 70°, there was no significant difference in the discrepancy between the actual and theoretical perforation points. Compared to judging the breakthrough point by CBCT, real‐time force feedback TSFE under robotic surgery achieved more accurate initial breakthrough point detection.Conclusions: The smaller the angle, the larger the breakthrough force for the drill. The real‐time force feedback of haptic robotic system during TSFE could provide reliable reference for dentists. More clinical studies are needed to further validate the application of robotic surgery assisted TSFE.
- 5 September 2024
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 28 (9) , 1-9
Influence of dental implant clinical experience on the accuracy of robot-assisted immediate implant placement: an in vitro study
Objectives To assess the accuracy and effectiveness among operators with different levels of experience in a robot-assisted immediate implant surgery. Materials and methods The study included four participants who had received dental training at the same institution but have varying levels of clinical experience in implant dentistry, denoted as undergraduate student (UG), dental resident (DR), specialist with no robot experience (IS) and specialist with robot experience (RS). Following comprehensive theoretical training in robot-assisted implant operation, each operator participated in five robotic-assisted implant procedures at 21 sites, resulting in the implant surgery of a total of 20 implants. Subsequently, the accuracy of the implants was assessed by analyzing the preoperative planning and the postoperative CBCT scans, and the time required for each procedure was also recorded. Results Angular deviation in UG, DR, IS and RS group was 0.82 ± 0.27°, 0.55 ± 0.27°, 0.83 ± 0.27°, and 0.56 ± 0.36°, respectively. The total deviation of the implant platform point was 0.28 ± 0.10 mm, 0.26 ± 0.16 mm, 0.34 ± 0.08 mm and 0.31 ± 0.06 mm, respectively. The total deviation of the apical point was 0.30 ± 0.08 mm, 0.25 ± 0.18 mm, 0.31 ± 0.09 mm, and 0.31 ± 0.05 mm, respectively. The time spent was 10.37 ± 0.57 min, 10.56 ± 1.77 min, 9.93 ± 0.78 min, and 11.76 ± 0.78 min for each operator. As the number of operations increased, the operation time decreased, but there was no significant difference in implant accuracy between the different groups. Conclusions Within the scope of this study, robot-assisted implant surgery demonstrated high accuracy, with no significant differences in performance between operators with varying levels of clinical experience or implant robot-user experience. Furthermore, the learning curve for robotic implant surgery is steep and consistent. Clinical relevance Robot-assisted implant surgery demonstrates consistent high accuracy across operators of varying clinical and robotic experience levels, highlighting its potential to standardize procedures and enhance predictability in clinical outcomes.
- 5 September 2024
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 28 (9) , 1-9
Influence of dental implant clinical experience on the accuracy of robot-assisted immediate implant placement: an in vitro study
Objectives To assess the accuracy and effectiveness among operators with different levels of experience in a robot-assisted immediate implant surgery. Materials and methods The study included four participants who had received dental training at the same institution but have varying levels of clinical experience in implant dentistry, denoted as undergraduate student (UG), dental resident (DR), specialist with no robot experience (IS) and specialist with robot experience (RS). Following comprehensive theoretical training in robot-assisted implant operation, each operator participated in five robotic-assisted implant procedures at 21 sites, resulting in the implant surgery of a total of 20 implants. Subsequently, the accuracy of the implants was assessed by analyzing the preoperative planning and the postoperative CBCT scans, and the time required for each procedure was also recorded. Results Angular deviation in UG, DR, IS and RS group was 0.82 ± 0.27°, 0.55 ± 0.27°, 0.83 ± 0.27°, and 0.56 ± 0.36°, respectively. The total deviation of the implant platform point was 0.28 ± 0.10 mm, 0.26 ± 0.16 mm, 0.34 ± 0.08 mm and 0.31 ± 0.06 mm, respectively. The total deviation of the apical point was 0.30 ± 0.08 mm, 0.25 ± 0.18 mm, 0.31 ± 0.09 mm, and 0.31 ± 0.05 mm, respectively. The time spent was 10.37 ± 0.57 min, 10.56 ± 1.77 min, 9.93 ± 0.78 min, and 11.76 ± 0.78 min for each operator. As the number of operations increased, the operation time decreased, but there was no significant difference in implant accuracy between the different groups. Conclusions Within the scope of this study, robot-assisted implant surgery demonstrated high accuracy, with no significant differences in performance between operators with varying levels of clinical experience or implant robot-user experience. Furthermore, the learning curve for robotic implant surgery is steep and consistent. Clinical relevance Robot-assisted implant surgery demonstrates consistent high accuracy across operators of varying clinical and robotic experience levels, highlighting its potential to standardize procedures and enhance predictability in clinical outcomes.
- 4 January 2024
- Published by Wiley in Clinical Oral Implants Research
- Vol. 35 (3) , 350-357
Effect of implant shape and length on the accuracy of robot‐assisted immediate implant surgery: An in vitro study
Objectives: To compare the accuracy of immediate implant placement of cylindrical implants (CI) and tapered implants (TI) of different lengths using a robotic dental implant system.Materials and Methods: CI and TI of three lengths (8, 10, and 12 mm) each were digitally planned and placed in a three‐dimensional printed extraction socket model under robotic guidance. There were six groups with three samples in each group, resulting in a total of 18 samples. Implant angular deviation, platform point deviation (total, lateral, depth), and implant apical point deviation (total, lateral, depth) were recorded and compared between the different groups.Results: The angular deviations for CI 8 mm, CI 10 mm, CI 12 mm, TI 8 mm, TI 10 mm, and TI 12 mm were 1.32° ± 0.19°, 1.03° ± 0.56°, 1.31° ± 0.38°, 1.27° ± 0.64°, 1.10° ± 0.43° and 1.05° ± 0.45°, respectively. The total deviations of platform and apical points for CI 8 mm, CI 10 mm, CI 12 mm, TI 8 mm, TI 10 mm, and TI 12 mm were 0.79 ± 0.18 mm, 0.77 ± 0.33 mm; 0.64 ± 0.21 mm, 0.55 ± 0.17 mm; 0.64 ± 0.37 mm, 0.65 ± 0.34 mm; 0.68 ± 0.26 mm, 0.71 ± 0.20 mm; 0.70 ± 0.12 mm, 0.66 ± 0.23 mm; and 0.71 ± 0.15 mm, 0.77 ± 0.29 mm, respectively, and had no significant differences.Conclusions: Within the limitation of this study, acceptable accuracy can be achieved for both TI and CI using robotic systems. Our study demonstrated that the implant shape and length did not affect the accuracy of immediate implant placement under robotic guidance in vitro. However, further trials are required to confirm their efficacy in clinical practice.
- 4 January 2024
- Published by Wiley in Clinical Oral Implants Research
- Vol. 35 (3) , 350-357
Effect of implant shape and length on the accuracy of robot‐assisted immediate implant surgery: An in vitro study
Objectives: To compare the accuracy of immediate implant placement of cylindrical implants (CI) and tapered implants (TI) of different lengths using a robotic dental implant system.Materials and Methods: CI and TI of three lengths (8, 10, and 12 mm) each were digitally planned and placed in a three‐dimensional printed extraction socket model under robotic guidance. There were six groups with three samples in each group, resulting in a total of 18 samples. Implant angular deviation, platform point deviation (total, lateral, depth), and implant apical point deviation (total, lateral, depth) were recorded and compared between the different groups.Results: The angular deviations for CI 8 mm, CI 10 mm, CI 12 mm, TI 8 mm, TI 10 mm, and TI 12 mm were 1.32° ± 0.19°, 1.03° ± 0.56°, 1.31° ± 0.38°, 1.27° ± 0.64°, 1.10° ± 0.43° and 1.05° ± 0.45°, respectively. The total deviations of platform and apical points for CI 8 mm, CI 10 mm, CI 12 mm, TI 8 mm, TI 10 mm, and TI 12 mm were 0.79 ± 0.18 mm, 0.77 ± 0.33 mm; 0.64 ± 0.21 mm, 0.55 ± 0.17 mm; 0.64 ± 0.37 mm, 0.65 ± 0.34 mm; 0.68 ± 0.26 mm, 0.71 ± 0.20 mm; 0.70 ± 0.12 mm, 0.66 ± 0.23 mm; and 0.71 ± 0.15 mm, 0.77 ± 0.29 mm, respectively, and had no significant differences.Conclusions: Within the limitation of this study, acceptable accuracy can be achieved for both TI and CI using robotic systems. Our study demonstrated that the implant shape and length did not affect the accuracy of immediate implant placement under robotic guidance in vitro. However, further trials are required to confirm their efficacy in clinical practice.
- 23 April 2023
- Published by Wiley in Clinical Oral Implants Research
- Vol. 34 (6) , 555-564
Comparative microcomputed tomography and histological analysis of the effects of a horizontal platelet‐rich fibrin bone block on maxillary sinus augmentation: A preclinical in vivo study
Background: While suggested to be effective in tissue regeneration, the effects of horizontal platelet‐rich fibrin (H‐PRF) bone block in sinus augmentation have not been verified in an animal model.Methods: A total of 12 male New Zealand white rabbits that underwent sinus augmentation were divided into two groups: deproteinized bovine bone mineral (DBBM) only and H‐PRF bone block. H‐PRF was prepared at 700 × g for 8 min using a horizontal centrifuge. The H‐PRF bone block was prepared by mixing 0.1 g DBBM with H‐PRF fragments and then adding liquid H‐PRF. Samples were collected after 4 and 8 weeks and analyzed using microcomputed tomography (micro‐CT) for vertical bone gain of the sinus, bone volume/total volume (BV/TV) percentage, trabecular number (Tb.N), trabecular thickness (Tb.Th) and trabecular separation (Tb.Sp). Then, histological analyses were performed to investigate new blood vessels, material residue, bone formation and osteoclasts.Results: Higher vertical bone gain of the sinus floor, BV/TV percentage, Tb.Th, and Tb.N and lower Tb.Sp were found in the H‐PRF bone block group at both time points compared with the DBBM group. Higher amounts of new blood vessels and more osteoclasts were found in the H‐PRF bone block group than in the DBBM group at both time points, especially in the regions close to the bone plate. More new bone formation and less material residue were observed in the H‐PRF bone block group at 8 weeks.Conclusions: H‐PRF bone block showed greater potential for sinus augmentation by promoting angiogenesis, bone formation and bone remodeling in a rabbit model.
- 23 April 2023
- Published by Wiley in Clinical Oral Implants Research
- Vol. 34 (6) , 555-564
Comparative microcomputed tomography and histological analysis of the effects of a horizontal platelet‐rich fibrin bone block on maxillary sinus augmentation: A preclinical in vivo study
Background: While suggested to be effective in tissue regeneration, the effects of horizontal platelet‐rich fibrin (H‐PRF) bone block in sinus augmentation have not been verified in an animal model.Methods: A total of 12 male New Zealand white rabbits that underwent sinus augmentation were divided into two groups: deproteinized bovine bone mineral (DBBM) only and H‐PRF bone block. H‐PRF was prepared at 700 × g for 8 min using a horizontal centrifuge. The H‐PRF bone block was prepared by mixing 0.1 g DBBM with H‐PRF fragments and then adding liquid H‐PRF. Samples were collected after 4 and 8 weeks and analyzed using microcomputed tomography (micro‐CT) for vertical bone gain of the sinus, bone volume/total volume (BV/TV) percentage, trabecular number (Tb.N), trabecular thickness (Tb.Th) and trabecular separation (Tb.Sp). Then, histological analyses were performed to investigate new blood vessels, material residue, bone formation and osteoclasts.Results: Higher vertical bone gain of the sinus floor, BV/TV percentage, Tb.Th, and Tb.N and lower Tb.Sp were found in the H‐PRF bone block group at both time points compared with the DBBM group. Higher amounts of new blood vessels and more osteoclasts were found in the H‐PRF bone block group than in the DBBM group at both time points, especially in the regions close to the bone plate. More new bone formation and less material residue were observed in the H‐PRF bone block group at 8 weeks.Conclusions: H‐PRF bone block showed greater potential for sinus augmentation by promoting angiogenesis, bone formation and bone remodeling in a rabbit model.