Carmen Salvadores Fernandez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Carmen Salvadores Fernandez has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Manish Kumar Tiwari
Nanoengineered Systems Laboratory, UCL Mechanical Engineering, University College London, London, WC1E 7JE, UK
5 shared publications - Adrien E. Desjardins
Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC, Canada
3 shared publications - Ann Blandford
Interaction Centre, University College London, London, UK
3 shared publications - Anna Louise David
University College London
3 shared publications - Dimitrios Siassakos
University College London
3 shared publications - Jeremy Opie
UCL Interaction Centre (UCLIC), University College London, London, United Kingdom
3 shared publications
Latest Publications
- Open Access
- 27 April 2026
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 10, e78845
Surgeons’ Perceptions on the Utility of a Conceptual Novel Force Sensor at the Surgeon-Tool Interface: Formative Interview Study
Background: Real-time force feedback is essential in many surgical specialties. While previous research has focused on force measured at the tool-tissue interface, little work has explored the benefits, limitations, or opportunities of measuring force at the surgeon-tool interface. Objective: This study aims to explore scenarios in which surgeons from different medical specialties and experience levels could benefit from receiving feedback on the force exerted at the surgeon-tool (or surgeon-tissue) interface. Methods: Exploratory qualitative research was conducted through interviews with medical practitioners (N=15). This study explored perceptions of a conceptual novel force-sensing surgical glove that could provide real-time feedback in terms of usability, utility, value, and limitations. Opportunities and barriers to implement a sensor of this type in clinical practice were also explored. Participants had experience in anesthetics, dental surgery, plastic and dermatological surgery, general surgery, and obstetrics and gynecology, as these surgical fields all require precise feedback on exerted forces. Results: Participants identified two key areas where a force sensor could yield significant benefits: (1) it could enhance surgical training through objective skill assessment and quantifiable feedback, and (2) it could provide valuable insights into the forces applied during practice, particularly in scenarios where other sensory feedback is masked. Participants appreciated that a sensorized glove that can provide real-time force sensing at the surgeon-tool interface would allow for continued feedback irrespective of the instrument, and integrate seamlessly into their current surgical workflow. Furthermore, as surgeons in some specialisms, for example, dental or obstetrics and gynecology, perform manual tasks, having a sensorized glove would provide feedback in instances where they are physically manipulating tissue. However, participants expressed concerns about accurately defining safe force ranges due to the variability in patients’ anatomical structures and the potential interference with tactile sensation. Conclusions: Surgeons from various clinical practices agreed that force sensing at the surgeon-tool interface could be valuable and provide them with optimal versatility as to when they would adopt force sensing. A sensorized glove could improve decision-making and surgical outcomes when other sources of information guiding force exertion are masked. Conversely, it could be detrimental when the organic information to guide force exertion is distorted when using the sensor. While the choice between interaction modalities is dependent on the accessibility of different senses during surgery, design suggestions as to where sensors are best placed on a sensorized glove are dependent on the instrument used or the type of manual procedure conducted.
- 27 April 2026
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 10, e78845
Open AccessSurgeons’ Perceptions on the Utility of a Conceptual Novel Force Sensor at the Surgeon-Tool Interface: Formative Interview Study
Background: Real-time force feedback is essential in many surgical specialties. While previous research has focused on force measured at the tool-tissue interface, little work has explored the benefits, limitations, or opportunities of measuring force at the surgeon-tool interface. Objective: This study aims to explore scenarios in which surgeons from different medical specialties and experience levels could benefit from receiving feedback on the force exerted at the surgeon-tool (or surgeon-tissue) interface. Methods: Exploratory qualitative research was conducted through interviews with medical practitioners (N=15). This study explored perceptions of a conceptual novel force-sensing surgical glove that could provide real-time feedback in terms of usability, utility, value, and limitations. Opportunities and barriers to implement a sensor of this type in clinical practice were also explored. Participants had experience in anesthetics, dental surgery, plastic and dermatological surgery, general surgery, and obstetrics and gynecology, as these surgical fields all require precise feedback on exerted forces. Results: Participants identified two key areas where a force sensor could yield significant benefits: (1) it could enhance surgical training through objective skill assessment and quantifiable feedback, and (2) it could provide valuable insights into the forces applied during practice, particularly in scenarios where other sensory feedback is masked. Participants appreciated that a sensorized glove that can provide real-time force sensing at the surgeon-tool interface would allow for continued feedback irrespective of the instrument, and integrate seamlessly into their current surgical workflow. Furthermore, as surgeons in some specialisms, for example, dental or obstetrics and gynecology, perform manual tasks, having a sensorized glove would provide feedback in instances where they are physically manipulating tissue. However, participants expressed concerns about accurately defining safe force ranges due to the variability in patients’ anatomical structures and the potential interference with tactile sensation. Conclusions: Surgeons from various clinical practices agreed that force sensing at the surgeon-tool interface could be valuable and provide them with optimal versatility as to when they would adopt force sensing. A sensorized glove could improve decision-making and surgical outcomes when other sources of information guiding force exertion are masked. Conversely, it could be detrimental when the organic information to guide force exertion is distorted when using the sensor. While the choice between interaction modalities is dependent on the accessibility of different senses during surgery, design suggestions as to where sensors are best placed on a sensorized glove are dependent on the instrument used or the type of manual procedure conducted.
- Open Access
- 13 June 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Surgeons’ perceptions on the utility of a novel force sensor at the surgeon-tool interface: a qualitative interview study (Preprint)
BACKGROUND Real-time force feedback is essential in many surgical specialties. While previous research has focused on force measured at the tool-tissue interface, little work has explored the benefits, limitations, or opportunities of measuring force at the surgeon-tool interface. OBJECTIVE This study aims to explore scenarios in which surgeons from different medical specialties and experience levels could benefit from receiving feedback on the force exerted at the surgeon-tool (or surgeon-tissue) interface. METHODS Exploratory qualitative research was conducted through interviews with medical practitioners (n=15). This study explored perceptions of an exemplar novel force-sensing surgical glove that provided real-time feedback in terms of usability, utility, value, and limitations. Opportunities and barriers for the sensor’s implementation in clinical practice were also explored. Participants had experience in anaesthetics, dental surgery, plastic and dermatological surgery, general surgery, and obstetrics and gynaecology as these surgical fields all require precise feedback on exerted forces. RESULTS Participants identified two key areas where the force sensor could yield significant benefits; (1) It could enhance surgical training through objective skill assessment and quantifiable feedback; and (2) it could provide valuable insights into the forces applied during practice, particularly in scenarios where other sensory feedback is masked. Participants appreciated that a sensorised glove that can provide real-time force sensing at the surgeon-tool interface would allow for continued feedback irrespective of the instrument and integrate seamlessly into their current surgical workflow. Furthermore, as surgeons in some specialisms, e.g., Dental or Obstetrics and Gynaecology, perform manual tasks, having a sensorised glove will provide feedback in instances where they are physically manipulating tissue. However, participants expressed concerns about accurately defining safe force ranges due to the variability in patients’ anatomical structures and the potential interference with tactile sensation. CONCLUSIONS Surgeons from various clinical practices agreed that force-sensing at the surgeon-tool interface could be valuable and provide them with optimal versatility as to when they would adopt force-sensing. The sensorised glove could improve decision making and surgical outcomes when other sources of information guiding force exertion are masked. Conversely, it could be detrimental when organic information to guide force exertion is distorted when using the sensor. While the choice between interaction modalities is dependent on the accessibility of different senses during surgery, design suggestions as to where sensors are best placed on a sensorised glove are dependent on the instrument used or type of manual procedure conducted.
- 13 June 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessSurgeons’ perceptions on the utility of a novel force sensor at the surgeon-tool interface: a qualitative interview study (Preprint)
BACKGROUND Real-time force feedback is essential in many surgical specialties. While previous research has focused on force measured at the tool-tissue interface, little work has explored the benefits, limitations, or opportunities of measuring force at the surgeon-tool interface. OBJECTIVE This study aims to explore scenarios in which surgeons from different medical specialties and experience levels could benefit from receiving feedback on the force exerted at the surgeon-tool (or surgeon-tissue) interface. METHODS Exploratory qualitative research was conducted through interviews with medical practitioners (n=15). This study explored perceptions of an exemplar novel force-sensing surgical glove that provided real-time feedback in terms of usability, utility, value, and limitations. Opportunities and barriers for the sensor’s implementation in clinical practice were also explored. Participants had experience in anaesthetics, dental surgery, plastic and dermatological surgery, general surgery, and obstetrics and gynaecology as these surgical fields all require precise feedback on exerted forces. RESULTS Participants identified two key areas where the force sensor could yield significant benefits; (1) It could enhance surgical training through objective skill assessment and quantifiable feedback; and (2) it could provide valuable insights into the forces applied during practice, particularly in scenarios where other sensory feedback is masked. Participants appreciated that a sensorised glove that can provide real-time force sensing at the surgeon-tool interface would allow for continued feedback irrespective of the instrument and integrate seamlessly into their current surgical workflow. Furthermore, as surgeons in some specialisms, e.g., Dental or Obstetrics and Gynaecology, perform manual tasks, having a sensorised glove will provide feedback in instances where they are physically manipulating tissue. However, participants expressed concerns about accurately defining safe force ranges due to the variability in patients’ anatomical structures and the potential interference with tactile sensation. CONCLUSIONS Surgeons from various clinical practices agreed that force-sensing at the surgeon-tool interface could be valuable and provide them with optimal versatility as to when they would adopt force-sensing. The sensorised glove could improve decision making and surgical outcomes when other sources of information guiding force exertion are masked. Conversely, it could be detrimental when organic information to guide force exertion is distorted when using the sensor. While the choice between interaction modalities is dependent on the accessibility of different senses during surgery, design suggestions as to where sensors are best placed on a sensorised glove are dependent on the instrument used or type of manual procedure conducted.
- Open Access
- 15 April 2025
- Published by Springer Nature in Cognition, Technology & Work
- Vol. 27 (1-2) , 277-295
Using mixed-fidelity to create effective environments
User testing is crucial for ensuring that systems meet user expectations, involving both low- and high-fidelity prototypes. Recently, mixed-fidelity prototypes, which blend various levels of detail, have gained popularity but are mainly used for evaluating single digital prototypes. Typically, medical devices are tested only after engineering is complete, using high-fidelity prototypes in realistic environments. This paper explores when different fidelity levels can be applied and which levels are suitable for creating realistic use environments in medical technology evaluations. We used the PRETAR framework to determine the appropriate fidelity for each artefact based on study constraints, resources, ethical considerations, and data analysis methods. Using a case study of a sensorised glove for vaginal examinations, we developed artefacts with varying levels of fidelity to replicate the fetal head and birth canal to test whether mixed-fidelity prototypes can replicate clinical environments effectively while being cost- and time-efficient and critically examine each design suggestion, discussing the benefits and limitations of our decisions.
- 15 April 2025
- Published by Springer Nature in Cognition, Technology & Work
- Vol. 27 (1-2) , 277-295
Open AccessUsing mixed-fidelity to create effective environments
User testing is crucial for ensuring that systems meet user expectations, involving both low- and high-fidelity prototypes. Recently, mixed-fidelity prototypes, which blend various levels of detail, have gained popularity but are mainly used for evaluating single digital prototypes. Typically, medical devices are tested only after engineering is complete, using high-fidelity prototypes in realistic environments. This paper explores when different fidelity levels can be applied and which levels are suitable for creating realistic use environments in medical technology evaluations. We used the PRETAR framework to determine the appropriate fidelity for each artefact based on study constraints, resources, ethical considerations, and data analysis methods. Using a case study of a sensorised glove for vaginal examinations, we developed artefacts with varying levels of fidelity to replicate the fetal head and birth canal to test whether mixed-fidelity prototypes can replicate clinical environments effectively while being cost- and time-efficient and critically examine each design suggestion, discussing the benefits and limitations of our decisions.
- Open Access
A Deep Learning Approach to Classify Surgical Skill in Microsurgery Using Force Data from a Novel Sensorised Surgical Glove
Microsurgery serves as the foundation for numerous operative procedures. Given its highly technical nature, the assessment of surgical skill becomes an essential component of clinical practice and microsurgery education. The interaction forces between surgical tools and tissues play a pivotal role in surgical success, making them a valuable indicator of surgical skill. In this study, we employ six distinct deep learning architectures (LSTM, GRU, Bi-LSTM, CLDNN, TCN, Transformer) specifically designed for the classification of surgical skill levels. We use force data obtained from a novel sensorized surgical glove utilized during a microsurgical task. To enhance the performance of our models, we propose six data augmentation techniques. The proposed frameworks are accompanied by a comprehensive analysis, both quantitative and qualitative, including experiments conducted with two cross-validation schemes and interpretable visualizations of the network’s decision-making process. Our experimental results show that CLDNN and TCN are the top-performing models, achieving impressive accuracy rates of 96.16% and 97.45%, respectively. This not only underscores the effectiveness of our proposed architectures, but also serves as compelling evidence that the force data obtained through the sensorized surgical glove contains valuable information regarding surgical skill.
Open AccessA Deep Learning Approach to Classify Surgical Skill in Microsurgery Using Force Data from a Novel Sensorised Surgical Glove
Microsurgery serves as the foundation for numerous operative procedures. Given its highly technical nature, the assessment of surgical skill becomes an essential component of clinical practice and microsurgery education. The interaction forces between surgical tools and tissues play a pivotal role in surgical success, making them a valuable indicator of surgical skill. In this study, we employ six distinct deep learning architectures (LSTM, GRU, Bi-LSTM, CLDNN, TCN, Transformer) specifically designed for the classification of surgical skill levels. We use force data obtained from a novel sensorized surgical glove utilized during a microsurgical task. To enhance the performance of our models, we propose six data augmentation techniques. The proposed frameworks are accompanied by a comprehensive analysis, both quantitative and qualitative, including experiments conducted with two cross-validation schemes and interpretable visualizations of the network’s decision-making process. Our experimental results show that CLDNN and TCN are the top-performing models, achieving impressive accuracy rates of 96.16% and 97.45%, respectively. This not only underscores the effectiveness of our proposed architectures, but also serves as compelling evidence that the force data obtained through the sensorized surgical glove contains valuable information regarding surgical skill.
- Open Access
- 11 March 2023
- Published by Wiley in Advanced Healthcare Materials
- Vol. 12 (17) , e2202673
A Triboelectric Nanocomposite for Sterile Sensing, Energy Harvesting, and Haptic Diagnostics in Interventional Procedures from Surgical Gloves
Advanced interfacial engineering has the potential to enable the successful realization of three features that are particularly important for a variety of healthcare applications: wettability control, antimicrobial activity to reduce infection risks, and sensing of physiological parameters. Here, a sprayable multifunctional triboelectric coating is exploited as a nontoxic, ultrathin tactile sensor that can be integrated directly on the fingertips of surgical gloves. The coating is based on a polymer blend mixed with zinc oxide (ZnO) nanoparticles, which enables antifouling and antibacterial properties. Additionally, the nanocomposite is superhydrophobic (self‐cleaning) and is not cytotoxic. The coating is also triboelectric and can be applied directly onto surgical gloves with printed electrodes. The sensorized gloves so obtained enable mechanical energy harvesting, force sensing, and detection of materials stiffness changes directly from fingertip, which may complement proprioceptive feedback for clinicians. Just as importantly, the sensors also work with a second glove on top offering better reassurance regarding sterility in interventional procedures. As a case study of clinical use for stiffness detection, the sensors demonstrate successful detection of pig anal sphincter injury ex vivo. This may lead to improving the accuracy of diagnosing obstetric anal sphincter injury, resulting in prompt repair, fewer complications, and improved quality of life.
- 11 March 2023
- Published by Wiley in Advanced Healthcare Materials
- Vol. 12 (17) , e2202673
Open AccessA Triboelectric Nanocomposite for Sterile Sensing, Energy Harvesting, and Haptic Diagnostics in Interventional Procedures from Surgical Gloves
Advanced interfacial engineering has the potential to enable the successful realization of three features that are particularly important for a variety of healthcare applications: wettability control, antimicrobial activity to reduce infection risks, and sensing of physiological parameters. Here, a sprayable multifunctional triboelectric coating is exploited as a nontoxic, ultrathin tactile sensor that can be integrated directly on the fingertips of surgical gloves. The coating is based on a polymer blend mixed with zinc oxide (ZnO) nanoparticles, which enables antifouling and antibacterial properties. Additionally, the nanocomposite is superhydrophobic (self‐cleaning) and is not cytotoxic. The coating is also triboelectric and can be applied directly onto surgical gloves with printed electrodes. The sensorized gloves so obtained enable mechanical energy harvesting, force sensing, and detection of materials stiffness changes directly from fingertip, which may complement proprioceptive feedback for clinicians. Just as importantly, the sensors also work with a second glove on top offering better reassurance regarding sterility in interventional procedures. As a case study of clinical use for stiffness detection, the sensors demonstrate successful detection of pig anal sphincter injury ex vivo. This may lead to improving the accuracy of diagnosing obstetric anal sphincter injury, resulting in prompt repair, fewer complications, and improved quality of life.