Longfei Dong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Longfei Dong has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Xiao Wu
Shandong Institute of Petroleum and Chemical Technology
4 shared publications Rui Zhang
Shandong Institute of Petroleum and Chemical Technology
3 shared publicationsYanping Xin
3 shared publicationsXiao Wu
2 shared publicationsCongcong Dong
Dongying Experimental Middle School, Dongying, Shandong, China
1 shared publicationFei Liu
Shandong Institute of Petroleum and Chemical Technology
1 shared publication
Latest Publications
- Open Access
- 10 March 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (11) , 17678-17688
Computational Fluid Dynamics Analysis of Falling Film Hydrodynamics in Spiral-Wound Heat Exchangers
This study presents a rigorous three-dimensional (3D) computational fluid dynamics (CFD) investigation into the complex hydrodynamic characteristics of an external falling liquid film flowing over horizontal tubes, focusing on a representative unit of the shell-side of a spiral-wound heat exchanger (SWHE). The primary objective is to quantitatively analyze the synergistic influence of key operating and structural parameters─namely, Reynolds number (Re), tube outer diameter (D), and tube spacing (S)─on the liquid film profile, coverage uniformity, and flow regime transition. A volume of fluid (VOF) model was established and validated to accurately track the gas–liquid interface. The analysis reveals three major findings: (1) Increasing the Reynolds number from Re = 300 to Re = 2000 drives a critical flow regime transition from a stable columnar flow dominated by viscous and gravitational forces to a highly dynamic fan flow. This transition significantly intensifies interfacial wave activity, which is quantified by a positive correlation between wave amplitude and Re. (2) An increase in tube diameter (D) promotes the concentration of the liquid film into distinct columns, decreasing film coverage uniformity and increasing local film thickness, as surface tension and inertia compete for liquid distribution across the larger surface. (3) The tube spacing (S) critically governs the hydrodynamics in the intertube region; an optimal spacing (S = 6 mm in this study) is identified where liquid columns effectively merge and redistribute, maximizing coverage while minimizing flow restriction. This quantitative analysis provides crucial, mechanistically grounded hydrodynamic data essential for the optimized structural design of industrial SWHEs, aiming to enhance overall heat and mass transfer efficiency.
- 10 March 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (11) , 17678-17688
Open AccessComputational Fluid Dynamics Analysis of Falling Film Hydrodynamics in Spiral-Wound Heat Exchangers
This study presents a rigorous three-dimensional (3D) computational fluid dynamics (CFD) investigation into the complex hydrodynamic characteristics of an external falling liquid film flowing over horizontal tubes, focusing on a representative unit of the shell-side of a spiral-wound heat exchanger (SWHE). The primary objective is to quantitatively analyze the synergistic influence of key operating and structural parameters─namely, Reynolds number (Re), tube outer diameter (D), and tube spacing (S)─on the liquid film profile, coverage uniformity, and flow regime transition. A volume of fluid (VOF) model was established and validated to accurately track the gas–liquid interface. The analysis reveals three major findings: (1) Increasing the Reynolds number from Re = 300 to Re = 2000 drives a critical flow regime transition from a stable columnar flow dominated by viscous and gravitational forces to a highly dynamic fan flow. This transition significantly intensifies interfacial wave activity, which is quantified by a positive correlation between wave amplitude and Re. (2) An increase in tube diameter (D) promotes the concentration of the liquid film into distinct columns, decreasing film coverage uniformity and increasing local film thickness, as surface tension and inertia compete for liquid distribution across the larger surface. (3) The tube spacing (S) critically governs the hydrodynamics in the intertube region; an optimal spacing (S = 6 mm in this study) is identified where liquid columns effectively merge and redistribute, maximizing coverage while minimizing flow restriction. This quantitative analysis provides crucial, mechanistically grounded hydrodynamic data essential for the optimized structural design of industrial SWHEs, aiming to enhance overall heat and mass transfer efficiency.
- Open Access
- 24 April 2025
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 71
Simulation study on enhanced heat transfer of annular inner rib tube in geothermal coaxial heat transfer wellbore
- 24 April 2025
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 71
Open AccessSimulation study on enhanced heat transfer of annular inner rib tube in geothermal coaxial heat transfer wellbore
- Open Access
- 8 April 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-11
Numerical study on falling film flow outside the refrigerant tube
The liquefied natural gas (LNG) floating production storage and offloading (FPSO) unit is a new type of floating production device developed for the exploitation, pretreatment, liquefaction, and storage of offshore natural gas. In this study, the shell side structure of the spiral-wound heat exchanger is analyzed, and the effects of varying the Reynolds number (Re), tube outer diameter, and number of distributors on the thickness of the shell-side liquid film are investigated. The results show that as the fluid flows down from the distributor, it hits the upper wall of the pipeline and diffuses evenly to both sides, before converging in between the two distributors. In the axial direction, the thickness of the liquid film increases first, reaches the highest at the peak, then decreases, reaches the lowest at the trough, and then increases again, forming a secondary peak at the drop. The thickness of the liquid film changes periodically, and the period is the distance between the two distributors. The thickness of the circumferential liquid film is negatively correlated with the circumferential angle, α. Moreover, the liquid film is thinnest at α = 120°, and is positively correlated with both the liquid mass flow rate and the outer diameter of the tube. The most uniform liquid film thickness is obtained when Re = 1500, the tube outer diameter is 12 mm, and the number of distributors is 6. The results from this study can guide the design of spiral-wound heat exchangers and facilitate their safe and efficient operation in natural gas liquefaction processes.
- 8 April 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-11
Open AccessNumerical study on falling film flow outside the refrigerant tube
The liquefied natural gas (LNG) floating production storage and offloading (FPSO) unit is a new type of floating production device developed for the exploitation, pretreatment, liquefaction, and storage of offshore natural gas. In this study, the shell side structure of the spiral-wound heat exchanger is analyzed, and the effects of varying the Reynolds number (Re), tube outer diameter, and number of distributors on the thickness of the shell-side liquid film are investigated. The results show that as the fluid flows down from the distributor, it hits the upper wall of the pipeline and diffuses evenly to both sides, before converging in between the two distributors. In the axial direction, the thickness of the liquid film increases first, reaches the highest at the peak, then decreases, reaches the lowest at the trough, and then increases again, forming a secondary peak at the drop. The thickness of the liquid film changes periodically, and the period is the distance between the two distributors. The thickness of the circumferential liquid film is negatively correlated with the circumferential angle, α. Moreover, the liquid film is thinnest at α = 120°, and is positively correlated with both the liquid mass flow rate and the outer diameter of the tube. The most uniform liquid film thickness is obtained when Re = 1500, the tube outer diameter is 12 mm, and the number of distributors is 6. The results from this study can guide the design of spiral-wound heat exchangers and facilitate their safe and efficient operation in natural gas liquefaction processes.
- Open Access
- 8 March 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (10) , 10546-10557
Experimental Study on External Heat Transfer Performance of Natural Gas Liquefaction Refrigerant Tube under Sloshing Condition
Spiral wound heat exchangers are the core equipment for natural gas liquefaction. Their heat transfer performance significantly affects the liquefaction process. This research investigates how varying sloshing amplitudes and periods affect the heat transfer and pressure drop characteristics of a spiral-wound heat exchanger subjected to yawing, heaving, and inclination. The UA value (where U represents the heat transfer coefficient in W·(m2·K)-1 and A denotes the heat exchange area in m2) exhibits an initial increase followed by a decrease as the yawing sloshing amplitude increases. The UA value at a yaw of 3° is 6.23% higher than the static value, while the UA value at a yaw of 9° is 19.53% lower. The fluctuation in the UA value decreases with an increase in the yawing sloshing period. When the sloshing period is 6 s, the UA value decreases by 16.46% compared to the static value. In contrast, when the sloshing period is 20 s, the UA value slowly increases by 4.19%. The UA value decreases with an increase in the amplitude of heaving sloshing. When the inclination starts, the UA value suddenly increases and then gradually decreases with time. Based on these observations, a mathematical model of heat transfer under yawing conditions is established. The heat transfer performance of spiral-wound heat exchanger under sloshing conditions is systematically studied, and the influence mechanism of sloshing on heat transfer efficiency of heat exchanger is revealed, which provides a new research perspective and experimental data for related fields.
- 8 March 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (10) , 10546-10557
Open AccessExperimental Study on External Heat Transfer Performance of Natural Gas Liquefaction Refrigerant Tube under Sloshing Condition
Spiral wound heat exchangers are the core equipment for natural gas liquefaction. Their heat transfer performance significantly affects the liquefaction process. This research investigates how varying sloshing amplitudes and periods affect the heat transfer and pressure drop characteristics of a spiral-wound heat exchanger subjected to yawing, heaving, and inclination. The UA value (where U represents the heat transfer coefficient in W·(m2·K)-1 and A denotes the heat exchange area in m2) exhibits an initial increase followed by a decrease as the yawing sloshing amplitude increases. The UA value at a yaw of 3° is 6.23% higher than the static value, while the UA value at a yaw of 9° is 19.53% lower. The fluctuation in the UA value decreases with an increase in the yawing sloshing period. When the sloshing period is 6 s, the UA value decreases by 16.46% compared to the static value. In contrast, when the sloshing period is 20 s, the UA value slowly increases by 4.19%. The UA value decreases with an increase in the amplitude of heaving sloshing. When the inclination starts, the UA value suddenly increases and then gradually decreases with time. Based on these observations, a mathematical model of heat transfer under yawing conditions is established. The heat transfer performance of spiral-wound heat exchanger under sloshing conditions is systematically studied, and the influence mechanism of sloshing on heat transfer efficiency of heat exchanger is revealed, which provides a new research perspective and experimental data for related fields.
- Open Access
- 11 December 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (12) , e0295315
Numerical simulation of heat transfer performance of spiral wound heat exchanger under sloshing condition
LNG floating production storage and offloading (FPSO) unit is a new type of floating production unit developed for offshore natural gas fields. It performs the functions of natural gas extraction, pretreatment, liquefaction, and storage. In this study, the heat transfer characteristics of a spiral-wound heat exchanger were studied using numerical simulations, which provides a basis for equipment selection and structural optimization of spiral-wound heat exchangers. The main research contents and conclusions are as follows. Under land-based simulation conditions, the heat transfer coefficient of the shell side of the spiral-wound heat exchanger decreases with an increase in the winding angle of the heat exchange tube, decreases with an increase in the spacing of the heat exchange tube, and increases with an increase in the outer diameter of the heat exchange tube. When the winding angle increased from 5° to 8°, the heat transfer coefficient decreased by 6.70%. The heat transfer coefficient of the shell side decreased by 13.21% when the heat exchange tube spacing increased from 14 to 17 mm. The heat transfer coefficient of the shell side increased by 22.89% when the outer diameter of the heat exchange tube increased from 9 to 12 mm. When the sloshing angle is constant, the heat transfer coefficient of the spiral-wound heat exchanger decreases with an increase in the winding angle and spacing of the heat exchange tubes, and increases with an increase in the outer diameter of the heat exchange tubes. When the structural parameters of the heat exchanger are constant, the heat transfer coefficient decreases as the sloshing angle increases. When the sloshing angle was less than 3°, the sloshing promoted heat transfer on the shell side. When the sloshing angle was higher than 7°, the heat transfer effect of the shell side deteriorated considerably, which weakened the heat transfer performance of the heat exchanger. When the sloshing period is constant, the heat transfer coefficient of the wound heat exchanger decreases with an increase in the winding angle and spacing of the heat exchange tubes, and increases with an increase in the outer diameter of the heat exchange tubes. When the structural parameters of the heat exchanger are constant, the heat transfer coefficient increases with sloshing period. When the sloshing period was greater than 15 s, the influence of sloshing on the heat transfer on the shell side of the heat exchanger was relatively weak.
- 11 December 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (12) , e0295315
Open AccessNumerical simulation of heat transfer performance of spiral wound heat exchanger under sloshing condition
LNG floating production storage and offloading (FPSO) unit is a new type of floating production unit developed for offshore natural gas fields. It performs the functions of natural gas extraction, pretreatment, liquefaction, and storage. In this study, the heat transfer characteristics of a spiral-wound heat exchanger were studied using numerical simulations, which provides a basis for equipment selection and structural optimization of spiral-wound heat exchangers. The main research contents and conclusions are as follows. Under land-based simulation conditions, the heat transfer coefficient of the shell side of the spiral-wound heat exchanger decreases with an increase in the winding angle of the heat exchange tube, decreases with an increase in the spacing of the heat exchange tube, and increases with an increase in the outer diameter of the heat exchange tube. When the winding angle increased from 5° to 8°, the heat transfer coefficient decreased by 6.70%. The heat transfer coefficient of the shell side decreased by 13.21% when the heat exchange tube spacing increased from 14 to 17 mm. The heat transfer coefficient of the shell side increased by 22.89% when the outer diameter of the heat exchange tube increased from 9 to 12 mm. When the sloshing angle is constant, the heat transfer coefficient of the spiral-wound heat exchanger decreases with an increase in the winding angle and spacing of the heat exchange tubes, and increases with an increase in the outer diameter of the heat exchange tubes. When the structural parameters of the heat exchanger are constant, the heat transfer coefficient decreases as the sloshing angle increases. When the sloshing angle was less than 3°, the sloshing promoted heat transfer on the shell side. When the sloshing angle was higher than 7°, the heat transfer effect of the shell side deteriorated considerably, which weakened the heat transfer performance of the heat exchanger. When the sloshing period is constant, the heat transfer coefficient of the wound heat exchanger decreases with an increase in the winding angle and spacing of the heat exchange tubes, and increases with an increase in the outer diameter of the heat exchange tubes. When the structural parameters of the heat exchanger are constant, the heat transfer coefficient increases with sloshing period. When the sloshing period was greater than 15 s, the influence of sloshing on the heat transfer on the shell side of the heat exchanger was relatively weak.
- Open Access
- 21 July 2023
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 8 (30) , 27467-27481
Experimental Study on the Effect of Pitch Sloshing on the Heat Transfer and Pressure Drop of an LNG Spiral-Wound Heat Exchanger
With the development and utilization of offshore liquefied natural gas, it is increasingly important to study the influence of the heat transfer performance of a spiral-wound heat exchanger under sloshing conditions. This study focused on the effects of different sloshing amplitudes and sloshing periods on the heat transfer and pressure drop performance of a heat exchanger. Through experimental research, the results showed that the fluctuation of the UA (U is the heat transfer coefficient; A is the heat exchange area) value first increased and then decreased with an increase in the sloshing amplitude. The UA value increased by 12.92% and decreased by 42.03% compared to the static value at 3 and 9°, respectively. The fluctuation in the UA value first decreased and then increased with an increase in the sloshing period. The UA value decreased by 36.66% and increased by 10.82% slowly compared to the static value when the sloshing period was 6 and 20 s, respectively. Based on this, a mathematical model of heat transfer under the condition of pitch sloshing was established.
- 21 July 2023
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 8 (30) , 27467-27481
Open AccessExperimental Study on the Effect of Pitch Sloshing on the Heat Transfer and Pressure Drop of an LNG Spiral-Wound Heat Exchanger
With the development and utilization of offshore liquefied natural gas, it is increasingly important to study the influence of the heat transfer performance of a spiral-wound heat exchanger under sloshing conditions. This study focused on the effects of different sloshing amplitudes and sloshing periods on the heat transfer and pressure drop performance of a heat exchanger. Through experimental research, the results showed that the fluctuation of the UA (U is the heat transfer coefficient; A is the heat exchange area) value first increased and then decreased with an increase in the sloshing amplitude. The UA value increased by 12.92% and decreased by 42.03% compared to the static value at 3 and 9°, respectively. The fluctuation in the UA value first decreased and then increased with an increase in the sloshing period. The UA value decreased by 36.66% and increased by 10.82% slowly compared to the static value when the sloshing period was 6 and 20 s, respectively. Based on this, a mathematical model of heat transfer under the condition of pitch sloshing was established.
- Open Access
- 15 March 2023
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 8 (12) , 11310-11317
Influence of Sloshing Conditions on the Pressure Drop and Heat Transfer of a Single-Layer Spiral-Wound LNG Heat Exchanger
In this study, the results and experimental data under static conditions are verified based on a calculation method. The deviation is controlled within 10%, which verifies the reliability of the experimental data. It is found that pitching has the most obvious influence on heat transfer. Through an analysis of the heat transfer coefficient on the shell side and the friction pressure drop along the path, the variation under rocking conditions is obtained.
- 15 March 2023
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 8 (12) , 11310-11317
Open AccessInfluence of Sloshing Conditions on the Pressure Drop and Heat Transfer of a Single-Layer Spiral-Wound LNG Heat Exchanger
In this study, the results and experimental data under static conditions are verified based on a calculation method. The deviation is controlled within 10%, which verifies the reliability of the experimental data. It is found that pitching has the most obvious influence on heat transfer. Through an analysis of the heat transfer coefficient on the shell side and the friction pressure drop along the path, the variation under rocking conditions is obtained.