Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Renaud Sales has a total of 12 co-authors. Here are the top co-authors by number of shared publications:

  • Chris Serrand

    UMR1318 INSERM - UM Institut Desbrest d'´Epidémiologie et de Santé Publique (IDESP), University of Montpellier, Montpellier, France; Department of Biostatistics, Public Health and Innovation in Methodology, Nîmes University Hospital, Nîmes, France

    2 shared publications
  • Joël Greffier

    IMAGINE UR UM 103 Department of Medical Imaging Nîmes University Hospital Montpellier University Nîmes France

    2 shared publications
  • Djamel Dabli

    Imagine UR UM 103, université de Montpellier, Department of Medical Imaging, centre hospitalier universitaire de Nîmes, Nîmes, France

    1 shared publication
  • Djamel Dabli

    IMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, Nîmes, France

    1 shared publication
  • Fabien de Oliveira

    Department of Medical Imaging, IMAGINE UR UM 103, Nîmes University Hospital, Montpellier University, 30900 Nîmes, France

    1 shared publication
  • Jean-Paul Beregi

    Imagine UR UM 103, université de Montpellier, Department of Medical Imaging, centre hospitalier universitaire de Nîmes, Nîmes, France

    1 shared publication

Latest Publications

  • Open Access

    Impact of a deep-learning image reconstruction algorithm on image quality and detection of solid lung lesions

    by Joël Greffier, Maxime Pastor, Quentin Durand, Renaud Sales, Chris Serrand, Jean-Paul Beregi, Djamel Dabli, Julien Frandon


  • Open Access

    First Results of a New Deep Learning Reconstruction Algorithm on Image Quality and Liver Metastasis Conspicuity for Abdominal Low-Dose CT

    by Joël Greffier, Quentin Durand, Chris Serrand, Renaud Sales, Fabien de Oliveira, Jean-Paul Beregi, Djamel Dabli, Julien Frandon

    The study’s aim was to assess the impact of a deep learning image reconstruction algorithm (Precise Image; DLR) on image quality and liver metastasis conspicuity compared with an iterative reconstruction algorithm (IR). This retrospective study included all consecutive patients with at least one liver metastasis having been diagnosed between December 2021 and February 2022. Images were reconstructed using level 4 of the IR algorithm (i4) and the Standard/Smooth/Smoother levels of the DLR algorithm. Mean attenuation and standard deviation were measured by placing the ROIs in the fat, muscle, healthy liver, and liver tumor. Two radiologists assessed the image noise and image smoothing, overall image quality, and lesion conspicuity using Likert scales. The study included 30 patients (mean age 70.4 ± 9.8 years, 17 men). The mean CTDIvol was 6.3 ± 2.1 mGy, and the mean dose-length product 314.7 ± 105.7 mGy.cm. Compared with i4, the HU values were similar in the DLR algorithm at all levels for all tissues studied. For each tissue, the image noise significantly decreased with DLR compared with i4 (p < 0.01) and significantly decreased from Standard to Smooth (−26 ± 10%; p < 0.01) and from Smooth to Smoother (−37 ± 8%; p < 0.01). The subjective image assessment confirmed that the image noise significantly decreased between i4 and DLR (p < 0.01) and from the Standard to Smoother levels (p < 0.01), but the opposite occurred for the image smoothing. The highest scores for overall image quality and conspicuity were found for the Smooth and Smoother levels.