Neeraj Sharma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Neeraj Sharma has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Shiru Sharma
School of Biomedical Engineering, Indian Institute of Technology, Banaras Hindu University, Varanasi, India
3 shared publications - Swapan Kumar Das
Wake Forest University School of Medicine
2 shared publications - Abhilash Mohapatra
Siksha ‘O’ Anusandhan (Deemed to be University), India
1 shared publication - Alaa Koleilat
Mayo Clinic
1 shared publication - Alok Prakash
School of Biomedical Engineering, Indian Institute of Technology (Banaras Hindu University), Varanasi, India
1 shared publication Alok Praksh
1 shared publication
Latest Publications
- Open Access
- 19 April 2026
- Published by Elsevier in SSRN Electronic Journal
Implementation of a novel myoelectric control with a force feedback mechanism to enhance the grasping capability of indigenously developed hand prosthesis
Below-elbow amputations have undesired effects on the functional capability of patients in doing activities of daily living. A myoelectric prosthesis having dexterous grasping feature can become a possible solution for such amputees. However, the available myoelectric prostheses are either expensive or unable to fulfill the functional needs of these amputees. This research presents the development of a low-cost 3D-printed myoelectric hand integrated with a novel force-feedback control mechanism. A self-designed surface electromyography (sEMG) sensor was deployed to provide user-intention based signal for actuation of prosthetic hand fingers. A force sensitive resistor (FSR) mounted at the thumb tip furnished force feedback information, which was further combined with a proportional control scheme to achieve precision in object grasping. The obtained results depicted that the developed hand prosthesis has the ability to accurately grasp the object for longer duration without any extra muscular effort and power consumption. The implemented hardware with a unique software control algorithm ensured a less sophisticated feedback-based system with enhanced grasping capability and negligible feedback delay. Moreover, the developed hand prosthesis was trialed on ten healthy subjects and one amputee for precise grasping of different objects. Such a low-cost hand based on a simple feedback control strategy can turn out to be a significant mode for amputees in order to perform daily routine grasping tasks.
- 19 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessImplementation of a novel myoelectric control with a force feedback mechanism to enhance the grasping capability of indigenously developed hand prosthesis
Below-elbow amputations have undesired effects on the functional capability of patients in doing activities of daily living. A myoelectric prosthesis having dexterous grasping feature can become a possible solution for such amputees. However, the available myoelectric prostheses are either expensive or unable to fulfill the functional needs of these amputees. This research presents the development of a low-cost 3D-printed myoelectric hand integrated with a novel force-feedback control mechanism. A self-designed surface electromyography (sEMG) sensor was deployed to provide user-intention based signal for actuation of prosthetic hand fingers. A force sensitive resistor (FSR) mounted at the thumb tip furnished force feedback information, which was further combined with a proportional control scheme to achieve precision in object grasping. The obtained results depicted that the developed hand prosthesis has the ability to accurately grasp the object for longer duration without any extra muscular effort and power consumption. The implemented hardware with a unique software control algorithm ensured a less sophisticated feedback-based system with enhanced grasping capability and negligible feedback delay. Moreover, the developed hand prosthesis was trialed on ten healthy subjects and one amputee for precise grasping of different objects. Such a low-cost hand based on a simple feedback control strategy can turn out to be a significant mode for amputees in order to perform daily routine grasping tasks.
- 1 March 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (3) , 035009
An optoelectronic muscle contraction sensor for prosthetic hand application
Surface electromyography (sEMG) is considered an established means for controlling prosthetic devices. sEMG suffers from serious issues such as electrical noise, motion artifact, complex acquisition circuitry, and high measuring costs because of which other techniques have gained attention. This work presents a new optoelectronic muscle (OM) sensor setup as an alternative to the EMG sensor for precise measurement of muscle activity. The sensor integrates a near-infrared light-emitting diode and phototransistor pair along with the suitable driver circuitry. The sensor measures skin surface displacement (that occurs during muscle contraction) by detecting backscattered infrared light from skeletal muscle tissue. With an appropriate signal processing scheme, the sensor was able to produce a 0–5 V output proportional to the muscular contraction. The developed sensor depicted decent static and dynamic features. In detecting muscle contractions from the forearm muscles of subjects, the sensor showed good similarity with the EMG sensor. In addition, the sensor displayed higher signal-to-noise ratio values and better signal stability than the EMG sensor. Furthermore, the OM sensor setup was utilized to control the rotation of the servomotor using an appropriate control scheme. Hence, the developed sensing system can measure muscle contraction information for controlling assistive devices.
- 1 March 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (3) , 035009
An optoelectronic muscle contraction sensor for prosthetic hand application
Surface electromyography (sEMG) is considered an established means for controlling prosthetic devices. sEMG suffers from serious issues such as electrical noise, motion artifact, complex acquisition circuitry, and high measuring costs because of which other techniques have gained attention. This work presents a new optoelectronic muscle (OM) sensor setup as an alternative to the EMG sensor for precise measurement of muscle activity. The sensor integrates a near-infrared light-emitting diode and phototransistor pair along with the suitable driver circuitry. The sensor measures skin surface displacement (that occurs during muscle contraction) by detecting backscattered infrared light from skeletal muscle tissue. With an appropriate signal processing scheme, the sensor was able to produce a 0–5 V output proportional to the muscular contraction. The developed sensor depicted decent static and dynamic features. In detecting muscle contractions from the forearm muscles of subjects, the sensor showed good similarity with the EMG sensor. In addition, the sensor displayed higher signal-to-noise ratio values and better signal stability than the EMG sensor. Furthermore, the OM sensor setup was utilized to control the rotation of the servomotor using an appropriate control scheme. Hence, the developed sensing system can measure muscle contraction information for controlling assistive devices.
- Open Access
- 1 March 2023
- Published by BPAS Publishers in International Journal of Biology Pharmacy and Allied Sciences
- Vol. 12 (3)
INVESTIGATION OF SKIN PERMEATION OF PHOTOSENSITIVE LIPOSOMES USING TAPE STRIPPING METHOD
- 1 March 2023
- Published by BPAS Publishers in International Journal of Biology Pharmacy and Allied Sciences
- Vol. 12 (3)
Open AccessINVESTIGATION OF SKIN PERMEATION OF PHOTOSENSITIVE LIPOSOMES USING TAPE STRIPPING METHOD
- 26 November 2022
- Published by Elsevier in Cancer Genetics
- Vol. 268-269, 16
49. Reduced performance of centromere 15 probe in association with African ancestry
- 26 November 2022
- Published by Elsevier in Cancer Genetics
- Vol. 268-269, 16
49. Reduced performance of centromere 15 probe in association with African ancestry
- Open Access
Coswara: A website application enabling COVID-19 screening by analysing respiratory sound samples and health symptoms
The COVID-19 pandemic has accelerated research on design of alternative, quick and effective COVID-19 diagnosis approaches. In this paper, we describe the Coswara tool, a website application designed to enable COVID-19 detection by analysing respiratory sound samples and health symptoms. A user using this service can log into a website using any device connected to the internet, provide there current health symptom information and record few sound sampled corresponding to breathing, cough, and speech. Within a minute of analysis of this information on a cloud server the website tool will output a COVID-19 probability score to the user. As the COVID-19 pandemic continues to demand massive and scalable population level testing, we hypothesize that the proposed tool provides a potential solution towards this.
Open AccessCoswara: A website application enabling COVID-19 screening by analysing respiratory sound samples and health symptoms
The COVID-19 pandemic has accelerated research on design of alternative, quick and effective COVID-19 diagnosis approaches. In this paper, we describe the Coswara tool, a website application designed to enable COVID-19 detection by analysing respiratory sound samples and health symptoms. A user using this service can log into a website using any device connected to the internet, provide there current health symptom information and record few sound sampled corresponding to breathing, cough, and speech. Within a minute of analysis of this information on a cloud server the website tool will output a COVID-19 probability score to the user. As the COVID-19 pandemic continues to demand massive and scalable population level testing, we hypothesize that the proposed tool provides a potential solution towards this.
- Open Access
- 1 January 2022
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1224 (1) , 012026
Performance Analysis of High Speed and Low Power Binary Adders
In all the arithmetic operations, addition is one of the most important and initial operations used in most of the mathematical equations. The operation is performed by many adders present in the digital world. These adders give us carries with preferred delay and power. The three main features like structure, logic, and compact circuit layout help design a better adder. This Paper aims to analyse and compare various additions for high-speed, low-power and fast calculation. The various adder designs seen in digital signal processing applications require computationally efficient adding and cumulative operations, so blocks with the required attributes must be carefully selected. Various techniques have been proposed to design efficient adders in terms of performance, low power consumption and area. This work focused on 16-bit implementations of highly optimized area-efficient Ripple Carry Adders (RCA) and Look Ahead Carry Adders (LAC), and carry select Adder. Finally, we can prove that the Carry look ahead Adder is very fast in all existing designs. These processes are simulated and synthesized in all ISE Xilinx 14.7 software.
- 1 January 2022
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1224 (1) , 012026
Open AccessPerformance Analysis of High Speed and Low Power Binary Adders
In all the arithmetic operations, addition is one of the most important and initial operations used in most of the mathematical equations. The operation is performed by many adders present in the digital world. These adders give us carries with preferred delay and power. The three main features like structure, logic, and compact circuit layout help design a better adder. This Paper aims to analyse and compare various additions for high-speed, low-power and fast calculation. The various adder designs seen in digital signal processing applications require computationally efficient adding and cumulative operations, so blocks with the required attributes must be carefully selected. Various techniques have been proposed to design efficient adders in terms of performance, low power consumption and area. This work focused on 16-bit implementations of highly optimized area-efficient Ripple Carry Adders (RCA) and Look Ahead Carry Adders (LAC), and carry select Adder. Finally, we can prove that the Carry look ahead Adder is very fast in all existing designs. These processes are simulated and synthesized in all ISE Xilinx 14.7 software.
- 22 December 2021
- Published by A and V Publications in Research Journal of Pharmaceutical Dosage Forms and Technology
- Vol. 13 (4) , 285-291
Formulation and Evaluation of Mucoadhesive in-Situ Nasal Gel of Tapentadol Hydrochloride
- 22 December 2021
- Published by A and V Publications in Research Journal of Pharmaceutical Dosage Forms and Technology
- Vol. 13 (4) , 285-291
Formulation and Evaluation of Mucoadhesive in-Situ Nasal Gel of Tapentadol Hydrochloride
- 14 December 2021
- Published by Springer Nature
- p. 1031-1041
Multi-objective Particle Swarm Optimization Based Enhanced Fuzzy C-Means Algorithm for the Segmentation of MRI Data
- 14 December 2021
- Published by Springer Nature
- p. 1031-1041
Multi-objective Particle Swarm Optimization Based Enhanced Fuzzy C-Means Algorithm for the Segmentation of MRI Data
- 17 May 2021
- Published by A and V Publications in Research Journal of Topical and Cosmetic Sciences
- Vol. 12 (1) , 59-63
Formulation Evaluation and Characterization of Fast Dissolving Tablets of Rofecoxib
- 17 May 2021
- Published by A and V Publications in Research Journal of Topical and Cosmetic Sciences
- Vol. 12 (1) , 59-63
Formulation Evaluation and Characterization of Fast Dissolving Tablets of Rofecoxib
- 1 January 2017
- Published by Inderscience Publishers in International Journal of Nanoparticles
- Vol. 9 (3) , 143
Phytofabrication, characterisation and antimicrobial studies of gold nanoparticles using Cannabis sativa (Bhang), leaf extract
International publishers of academic, scientific and professional journals since 1979.
- 1 January 2017
- Published by Inderscience Publishers in International Journal of Nanoparticles
- Vol. 9 (3) , 143
Phytofabrication, characterisation and antimicrobial studies of gold nanoparticles using Cannabis sativa (Bhang), leaf extract
International publishers of academic, scientific and professional journals since 1979.