Jingkai Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jingkai Li has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Chuming Yan
Neurology Department, Xuanwu Hospital of Capital Medical University, Beijing, People’s Republic of China
1 shared publication - Fan Yu
Department of Radiology and Nuclear Medicine, Xuanwu Hospital Capital Medical University, Changchun Street No. 45, Beijing 100053, China
1 shared publication - Jie Lu
Department of Radiology and Nuclear Medicine, Xuanwu Hospital Capital Medical University, Beijing, China
1 shared publication Miao Zhang
Department of Radiology (F.Y., M.Z., J.L., J.L.), Xuanwu Hospital Capital Medical University, Beijing, China
1 shared publication- Qingfeng Ma
Department of Neurology, Xuanwu Hospital, Capital Medical University, Beijing, China
1 shared publication Yingjie Zhang
Department of Neurology (C.Y., Y.Z., Z.W., Q.M.), Xuanwu Hospital Capital Medical University, Beijing, China
1 shared publication
Latest Publications
- 1 April 2023
- Published by Wolters Kluwer Health in Stroke
- Vol. 54 (4) , 1037-1045
Multidelay Arterial Spin Labeling Versus Computed Tomography Perfusion in Penumbra Volume of Acute Ischemic Stroke
Background:Multidelay arterial spin labeling (ASL) is a novel perfusion method of ASL, with arterial transit time (ATT) calculated by multiple postlabeling delays to correct cerebral blood flow (CBF). We verify the accuracy of multidelay ASL in evaluating the ischemic penumbra and perfusion levels in patients with acute ischemic stroke, compared with computed tomography perfusion (CTP). Methods:Patients with acute ischemic stroke with anterior circulation large vessel occlusion received baseline CTP, multidelay ASL, and diffusion-weighted imaging (DWI) in succession. Multidelay ASL image was processed to reconstruct ATT, CBF without ATT correction, and CBF corrected by ATT. The consistency of hypoperfusion and ischemic penumbra volume calculated by CTP and multidelay ASL were quantified by intraclass correlation coefficient (ICC) in 2-way mixed effects, absolute agreement, and single measure. Wilcoxon signed-rank test was used to compare the difference in penumbra volume between CTP, corrected ASL, and uncorrected ASL. Results:Thirty patients were included. Hypoperfusion volume based on multidelay ASL with different thresholds were 117.95 (87.77-151.49) mL for corrected relative CBF<40%, 130.29 (85.99-249.37) mL for CBF corrected by ATT0.05) compared with the volume of CTP, and consistency was almost excellent (ICC, 0.91) and substantial consistent (ICC, 0.727). The volumes of ischemic penumbra were 91.00 (42.68-125.27) mL for corrected relative CBF<40%-DWI, 108.94 (62.03-150.86) mL for CBF corrected by ATT0.05). The consistency was excellent (ICC, 0.822) and moderate (ICC, 0.501), respectively. The volume of uncorrected relative CBF <40%-DWI was 209.57 (123.21-292.45) mL, statistically larger than corrected relative CBF <40%-DWI (P<0.001) and CTP (P<0.001). The volume of uncorrected CBF<20 mL center dot 100g(-1)center dot min(-1)-DWI was 186.23 (86.56-298.22) mL, statistically larger than CBF corrected by ATT<20 mL center dot 100g(-1)center dot min(-1)-DWI (P<0.001) and CTP(P<0.001). Conclusions:The volume of ischemic penumbra determined by CBF/DWI mismatch based on multidelay ASL is consistent with CTP. The penumbra volume calculated by CBF adjusted by ATT is more accurate.
- 1 April 2023
- Published by Wolters Kluwer Health in Stroke
- Vol. 54 (4) , 1037-1045
Multidelay Arterial Spin Labeling Versus Computed Tomography Perfusion in Penumbra Volume of Acute Ischemic Stroke
Background:Multidelay arterial spin labeling (ASL) is a novel perfusion method of ASL, with arterial transit time (ATT) calculated by multiple postlabeling delays to correct cerebral blood flow (CBF). We verify the accuracy of multidelay ASL in evaluating the ischemic penumbra and perfusion levels in patients with acute ischemic stroke, compared with computed tomography perfusion (CTP). Methods:Patients with acute ischemic stroke with anterior circulation large vessel occlusion received baseline CTP, multidelay ASL, and diffusion-weighted imaging (DWI) in succession. Multidelay ASL image was processed to reconstruct ATT, CBF without ATT correction, and CBF corrected by ATT. The consistency of hypoperfusion and ischemic penumbra volume calculated by CTP and multidelay ASL were quantified by intraclass correlation coefficient (ICC) in 2-way mixed effects, absolute agreement, and single measure. Wilcoxon signed-rank test was used to compare the difference in penumbra volume between CTP, corrected ASL, and uncorrected ASL. Results:Thirty patients were included. Hypoperfusion volume based on multidelay ASL with different thresholds were 117.95 (87.77-151.49) mL for corrected relative CBF<40%, 130.29 (85.99-249.37) mL for CBF corrected by ATT0.05) compared with the volume of CTP, and consistency was almost excellent (ICC, 0.91) and substantial consistent (ICC, 0.727). The volumes of ischemic penumbra were 91.00 (42.68-125.27) mL for corrected relative CBF<40%-DWI, 108.94 (62.03-150.86) mL for CBF corrected by ATT0.05). The consistency was excellent (ICC, 0.822) and moderate (ICC, 0.501), respectively. The volume of uncorrected relative CBF <40%-DWI was 209.57 (123.21-292.45) mL, statistically larger than corrected relative CBF <40%-DWI (P<0.001) and CTP (P<0.001). The volume of uncorrected CBF<20 mL center dot 100g(-1)center dot min(-1)-DWI was 186.23 (86.56-298.22) mL, statistically larger than CBF corrected by ATT<20 mL center dot 100g(-1)center dot min(-1)-DWI (P<0.001) and CTP(P<0.001). Conclusions:The volume of ischemic penumbra determined by CBF/DWI mismatch based on multidelay ASL is consistent with CTP. The penumbra volume calculated by CBF adjusted by ATT is more accurate.