RGRayk Grune

Rayk Grune

*This is an algorithmically generated author record based on publicly available information.

Rayk Grune has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Power-Hardware Design and Topologies of Converter-Based Grid Emulators for Wind Turbines

    by Zejie Li, Xiongfei Wang, Fangzhou Zhao, Stig Munk-Nielsen, Martin Geske, Rayk Grune, Daniel Bo Rønnest Andersen, Miguel Garnelo Rodriguez

    Power-electronic-based grid emulators (GEs) emerge as a favorable method for testing grid-code compliances of wind turbines (WTs), thanks to their full controllability and improved efficiency. To accommodate the increasing power and voltage levels of WTs, scalability becomes a critical requirement for the topologies of converter-based GEs. This paper identifies first the power rating of future GEs based on the system architecture and the evolution of WTs, followed by evaluating converter topologies of GEs for high scalability. Design considerations of power semiconductor devices, step-up transformers, dc chopper and dc capacitors are also discussed for existing and prospective GEs.


  • Open Access

    Validation of Wind Turbine Models Based on Test Bench Measurements: A System for Theoretical Representation of the Grid Replica

    by Anica Frehn, Jens Sdun, Rayk Grune, Antonello Monti

    In recent years, nacelle test benches for wind turbines have been developed internationally. New standards are currently being developed that explicitly refer to the measurement of the electrical properties of wind turbines on these test benches. Thus, they are suitable for measuring the electrical properties required for certification. Another part of the certification is the creation and validation of suitable models of the wind turbine, which are used for stability analyses of the utility grid. Validation requires a suitable model of grid replication on the test benches, which is not yet covered by any applicable standard. Such models should be as simplified a representation of the artificial grid replication as possible to ensure that they are accessible to certification bodies. A model of the grid emulator installed at the CWD of RWTH Aachen University, which was validated with real measurement data, serves as a reference. A step-by-step reduction of the model’s depth up to the system’s technical representation is followed by a model evaluation with respect to the level of detail and an analysis of time and frequency. The evaluation shows that even a highly simplified model consisting of a reference voltage and an impedance replica meets the requirements for the validation of wind turbine models according to IEC 61400-27-2.


  • Open Access

    Medium-Voltage Megawatt Power-Electronic-Based Grid Emulators: Testing Capability Requirements and Dynamics Challenges—A Review

    by Zejie Li, Fangzhou Zhao, Xiongfei Wang, Stig Munk-Nielsen, Martin Geske, Rayk Grune, Daniel Bo Rønnest Andersen, Miguel Garnelo Rodriguez

    Power-electronic-based grid emulators are emerging as a promising way to test the grid-code compliance of renewable energy resources. Yet, the ever-increasing power and voltage levels of device under test pose new requirements and challenges to power-electronic-based grid emulators. This paper first gives an overview of testing capability requirements based on the recent grid codes and standards, then discusses the resulted dynamic interactions and solutions for power-electronic-based grid emulators. Perspectives on the open issues and emerging trends of grid emulators are finally shared.


  • Open Access

    A discussion on the characterization of grid emulators by apparent power rating and short-circuit power

    by Rayk Grune, Martin Geske

    Wind turbines are a driving force in the change towards renewable energies today. Offshore wind turbines have reached power ratings around 15 MW, and the growth continues. Grid emulators have become inevitable for the test and validation of wind turbines and subsystems at full scale. Yet, large investments for new installations present major challenges.Therefore, the following discussion outlines basic design aspects for the grid emulator main components: converter, transformer, and filter. The aim is to clarify the implications of requirements on the design to exhaust ratings for minimum investments, and to satisfy testing against the most recent standards and grid codes. Appropriate ratings are derived based on steady-state and transient test needs. It is shown how much overrating is specifically needed and why the converter is usually rated a multiple compared to the device under test. Further dimensioning criteria such as power quality, switching frequency, and filter size are discussed in this context.Finally, the capacity of grid emulators is often characterized by the short-circuit power. Two essentially different variants of short-circuit power are introduced, either being dependent on the converter peak current or the passive components impedance. While the first one reveals the overload capability, the latter represents a proper measure for grid strength. However, the emulated grid strength can be adjusted in a limited bandwidth using impedance control. The concept might be confusing at first glance, but it effectively decouples the virtual short-circuit power from the ratings of the power hardware.