Jifeng Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jifeng Li has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Guanyu Lin
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
4 shared publications - Guanyu Lin
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
3 shared publications - Bo Li
Chinese Academy of Sciences
2 shared publications - Heng Wu
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
2 shared publications - Jianing Wang
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
2 shared publications - Limin He
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
2 shared publications
Latest Publications
- Open Access
Novel OA-ICOS Sensor for Real-Time Quantification of Enteric Methane from Ruminants
Methane (CH4) is a potent greenhouse gas, with livestock rumination being a significant contributor to global emissions. This study developed a real-time monitoring system utilizing Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS) to simultaneously track rumination behavior and CH4 concentrations in cattle breath. By optimizing the off-axis integrated cavity structure and implementing a specialized environmental control system, we enhanced stability and detection accuracy, achieving a rapid 3 s response time to dynamic concentration changes. Laboratory stability tests and Allan deviation analysis demonstrated a minimum detection limit of 0.07 ppm. Continuous field monitoring of Simmental cattle revealed a daily methane production of approximately 311.83 L. The emission rates exhibited a distinct double-peak pattern heavily influenced by feeding schedules. Furthermore, a positive correlation was observed between the time elapsed post feeding and both the frequency and intensity of methane emission peaks. This method enables highly dynamic, stable, long-term monitoring of greenhouse gas emissions from ruminants, providing a robust tool for quantifying emissions and informing scientific feeding practices.
Open AccessNovel OA-ICOS Sensor for Real-Time Quantification of Enteric Methane from Ruminants
Methane (CH4) is a potent greenhouse gas, with livestock rumination being a significant contributor to global emissions. This study developed a real-time monitoring system utilizing Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS) to simultaneously track rumination behavior and CH4 concentrations in cattle breath. By optimizing the off-axis integrated cavity structure and implementing a specialized environmental control system, we enhanced stability and detection accuracy, achieving a rapid 3 s response time to dynamic concentration changes. Laboratory stability tests and Allan deviation analysis demonstrated a minimum detection limit of 0.07 ppm. Continuous field monitoring of Simmental cattle revealed a daily methane production of approximately 311.83 L. The emission rates exhibited a distinct double-peak pattern heavily influenced by feeding schedules. Furthermore, a positive correlation was observed between the time elapsed post feeding and both the frequency and intensity of methane emission peaks. This method enables highly dynamic, stable, long-term monitoring of greenhouse gas emissions from ruminants, providing a robust tool for quantifying emissions and informing scientific feeding practices.
- Open Access
Research on the High Tolerance Flexible Support Structure for the Primary Mirror in Cassegrain Optical Systems
Conventional mirror support structures often fail to meet optical system tolerances due to inadequate mitigation of the installation stresses caused by machining-induced surface irregularities and inclinations. This study proposes a novel single-point central support using an arc-shaped flexible hinge. Materials for the mirror and support structure are carefully selected based on their properties, and the optimal dimensions are determined through stiffness analysis. The new flexible support structure is detailed in this work. Simulations show that the mirror assembly achieves a first-order frequency of 296.66 Hz. Under separate triaxial gravitational and thermal loads at −40 °C and 50 °C, the mirror’s surface figure accuracy RMS remains better than λ/45 (λ = 632.8 nm). With a 0.008 mm forced displacement applied to the installation surface, the RMS change in the mirror’s surface figure is less than λ/200, meeting structural design specifications. In practical assembly tests, even when surface irregularities exceed tolerances by more than double, the RMS change in the mirror’s surface figure is only 7 nm. This design effectively ensures high-precision surface quality while significantly reducing assembly difficulty and installation surface precision requirements, achieving a large-tolerance assembly. It provides a valuable reference for mirror support design in imaging optical systems.
Open AccessResearch on the High Tolerance Flexible Support Structure for the Primary Mirror in Cassegrain Optical Systems
Conventional mirror support structures often fail to meet optical system tolerances due to inadequate mitigation of the installation stresses caused by machining-induced surface irregularities and inclinations. This study proposes a novel single-point central support using an arc-shaped flexible hinge. Materials for the mirror and support structure are carefully selected based on their properties, and the optimal dimensions are determined through stiffness analysis. The new flexible support structure is detailed in this work. Simulations show that the mirror assembly achieves a first-order frequency of 296.66 Hz. Under separate triaxial gravitational and thermal loads at −40 °C and 50 °C, the mirror’s surface figure accuracy RMS remains better than λ/45 (λ = 632.8 nm). With a 0.008 mm forced displacement applied to the installation surface, the RMS change in the mirror’s surface figure is less than λ/200, meeting structural design specifications. In practical assembly tests, even when surface irregularities exceed tolerances by more than double, the RMS change in the mirror’s surface figure is only 7 nm. This design effectively ensures high-precision surface quality while significantly reducing assembly difficulty and installation surface precision requirements, achieving a large-tolerance assembly. It provides a valuable reference for mirror support design in imaging optical systems.
- Open Access
OA−ICOS−Based Oxygen and Carbon Dioxide Sensors for Field Applications in Gas Reflux Chicken Coops
To facilitate the effective assessment of respiratory entropy during poultry breeding, a novel oxygen (O2) and carbon dioxide (CO2) sensor was developed based on the off−axis integrated cavity output spectroscopy technique, featuring effective absorption optical paths of 15.5 m and 8.5 m, respectively. The sensor employs integrated environmental control technology, substantially enhancing detection precision. To improve the instrument’s response speed, the miniaturization of the cavity and structural optimization were implemented, achieving a rapid response time of merely 6.22 s, addressing the stringent requirements for quick responsiveness in poultry respiration thermometry research. A signal processing model tailored for on−site applications was designed, boosting the system’s signal−to−noise ratio by 4.7 times under complex environmental noise conditions. Utilizing Allan variance analysis, the sensor’s detection limits for O2 and CO2 were ascertained to be 2.9 ppm and 7.4 ppb, respectively. A 24−h field application test conducted in Gongzhuling demonstrated that the sensor’s results align with the respiratory characteristics of poultry under normal physiological conditions, validating its extensive potential for application in respiratory analysis, environmental monitoring, and industrial sectors.
Open AccessOA−ICOS−Based Oxygen and Carbon Dioxide Sensors for Field Applications in Gas Reflux Chicken Coops
To facilitate the effective assessment of respiratory entropy during poultry breeding, a novel oxygen (O2) and carbon dioxide (CO2) sensor was developed based on the off−axis integrated cavity output spectroscopy technique, featuring effective absorption optical paths of 15.5 m and 8.5 m, respectively. The sensor employs integrated environmental control technology, substantially enhancing detection precision. To improve the instrument’s response speed, the miniaturization of the cavity and structural optimization were implemented, achieving a rapid response time of merely 6.22 s, addressing the stringent requirements for quick responsiveness in poultry respiration thermometry research. A signal processing model tailored for on−site applications was designed, boosting the system’s signal−to−noise ratio by 4.7 times under complex environmental noise conditions. Utilizing Allan variance analysis, the sensor’s detection limits for O2 and CO2 were ascertained to be 2.9 ppm and 7.4 ppb, respectively. A 24−h field application test conducted in Gongzhuling demonstrated that the sensor’s results align with the respiratory characteristics of poultry under normal physiological conditions, validating its extensive potential for application in respiratory analysis, environmental monitoring, and industrial sectors.
- Open Access
- 27 June 2023
- Published by MDPI AG in Remote Sensing
- Vol. 15 (13) , 3288
Prediction Aerospace Software to Detect Solar Activity and the Fast Tracking of Solar Activity Using Remote Sensing Instruments in Orbit
At present, solar remote sensing instruments face problems regarding the short detection time for solar activity and the need to preheat the electronics before detection. The accurate orbit prediction function ensures that the maximum error of the payload electronics system preheating time is less than 8 s, enabling the electronics to obtain stable and reliable solar remote sensing data, and allowing the prediction function to adapt to the changes in preheating time and the limit position of turntable rotation. To achieve the complete detection of solar activity by a payload in orbit, a turntable with two directions of rotation was accurately controlled to achieve rapid capture and track the Sun’s activity, and the delay time for tracking the Sun successfully was less than 8 s to ensure that the payload made full use of the solar detection time for full detection. The turntable’s tracking error was less than 0.002°, allowing the payload to obtain high-precision solar remote sensing data in orbit. The above methods enable the payload to realize the complete, stable, and high-precision detection of solar activity in orbit for wavelengths ranging approximately from 165 nm to 2400 nm.
- 27 June 2023
- Published by MDPI AG in Remote Sensing
- Vol. 15 (13) , 3288
Open AccessPrediction Aerospace Software to Detect Solar Activity and the Fast Tracking of Solar Activity Using Remote Sensing Instruments in Orbit
At present, solar remote sensing instruments face problems regarding the short detection time for solar activity and the need to preheat the electronics before detection. The accurate orbit prediction function ensures that the maximum error of the payload electronics system preheating time is less than 8 s, enabling the electronics to obtain stable and reliable solar remote sensing data, and allowing the prediction function to adapt to the changes in preheating time and the limit position of turntable rotation. To achieve the complete detection of solar activity by a payload in orbit, a turntable with two directions of rotation was accurately controlled to achieve rapid capture and track the Sun’s activity, and the delay time for tracking the Sun successfully was less than 8 s to ensure that the payload made full use of the solar detection time for full detection. The turntable’s tracking error was less than 0.002°, allowing the payload to obtain high-precision solar remote sensing data in orbit. The above methods enable the payload to realize the complete, stable, and high-precision detection of solar activity in orbit for wavelengths ranging approximately from 165 nm to 2400 nm.
- Open Access
A Spectral Encoding Simulator for Broadband Active Illumination and Reconstruction-Based Spectral Measurement
Spectral reflectance or transmittance measurements provide intrinsic information on the material of an object and are widely used in remote sensing, agriculture, diagnostic medicine, etc. Most reconstruction-based spectral reflectance or transmittance measurement methods based on broadband active illumination use narrow-band LEDs or lamps combined with specific filters as spectral encoding light sources. These light sources cannot achieve the designed spectral encoding with a high resolution and accuracy due to their low degree of freedom for adjustment, leading to inaccurate spectral measurements. To address this issue, we designed a spectral encoding simulator for active illumination. The simulator is composed of a prismatic spectral imaging system and a digital micromirror device. The spectral wavelengths and intensity are adjusted by switching the micromirrors. We used it to simulate spectral encodings according to the spectral distribution on micromirrors and solved the DMD patterns corresponding to the spectral encodings with a convex optimization algorithm. To verify the applicability of the simulator for spectral measurements based on active illumination, we used it to numerically simulate existing spectral encodings. We also numerically simulated a high-resolution Gaussian random measurement encoding for compressed sensing and measured the spectral reflectance of one vegetation type and two minerals through numerical simulations. We reconstructed the spectral transmittance of a calibrated filter through an experiment. The results show that the simulator can measure the spectral reflectance or transmittance with a high resolution and accuracy.
Open AccessA Spectral Encoding Simulator for Broadband Active Illumination and Reconstruction-Based Spectral Measurement
Spectral reflectance or transmittance measurements provide intrinsic information on the material of an object and are widely used in remote sensing, agriculture, diagnostic medicine, etc. Most reconstruction-based spectral reflectance or transmittance measurement methods based on broadband active illumination use narrow-band LEDs or lamps combined with specific filters as spectral encoding light sources. These light sources cannot achieve the designed spectral encoding with a high resolution and accuracy due to their low degree of freedom for adjustment, leading to inaccurate spectral measurements. To address this issue, we designed a spectral encoding simulator for active illumination. The simulator is composed of a prismatic spectral imaging system and a digital micromirror device. The spectral wavelengths and intensity are adjusted by switching the micromirrors. We used it to simulate spectral encodings according to the spectral distribution on micromirrors and solved the DMD patterns corresponding to the spectral encodings with a convex optimization algorithm. To verify the applicability of the simulator for spectral measurements based on active illumination, we used it to numerically simulate existing spectral encodings. We also numerically simulated a high-resolution Gaussian random measurement encoding for compressed sensing and measured the spectral reflectance of one vegetation type and two minerals through numerical simulations. We reconstructed the spectral transmittance of a calibrated filter through an experiment. The results show that the simulator can measure the spectral reflectance or transmittance with a high resolution and accuracy.
- Open Access
- 21 April 2023
- Published by MDPI AG in Remote Sensing
- Vol. 15 (8) , 2213
Methods of Analyzing the Error and Rectifying the Calibration of a Solar Tracking System for High-Precision Solar Tracking in Orbit
Reliability is the most critical characteristic of space missions, for example in capturing and tracking moving targets. To this end, two methods are designed to track sunlight using solar remote-sensing instruments (SRSIs). The primary method is to use the offset angles of the guide mirror for closed-loop tracking, while the alternative method is to use the sunlight angles, calculated from the satellite attitude, solar vector, and mechanical installation correction parameters, for open-loop tracking. By comprehensively analyzing the error and rectifying the calibration of the solar tracking system, we demonstrate that the absolute value of the azimuth tracking precision is less than 0.0121° and the pitch is less than 0.0037° with the primary method. Correspondingly, they are 0.0992° and 0.0960° with the alternative method. These precisions meet the requirements of SRSIs. In addition, recalibration due to mechanical vibration during the satellite’s launch may invalidate the above methods, leading to the failure of SRSIs. Hence, we propose a dedicated injection parameter strategy to rectify the sunlight angles to capture and track the sunlight successfully. The stable and effective results in the ultraviolet to near-infrared spectrum validate the SRSI’s high-precision sunlight tracking performance. Furthermore, the above methods can also be applied to all orbital inclinations and may provide a solution for capturing and tracking moving targets.
- 21 April 2023
- Published by MDPI AG in Remote Sensing
- Vol. 15 (8) , 2213
Open AccessMethods of Analyzing the Error and Rectifying the Calibration of a Solar Tracking System for High-Precision Solar Tracking in Orbit
Reliability is the most critical characteristic of space missions, for example in capturing and tracking moving targets. To this end, two methods are designed to track sunlight using solar remote-sensing instruments (SRSIs). The primary method is to use the offset angles of the guide mirror for closed-loop tracking, while the alternative method is to use the sunlight angles, calculated from the satellite attitude, solar vector, and mechanical installation correction parameters, for open-loop tracking. By comprehensively analyzing the error and rectifying the calibration of the solar tracking system, we demonstrate that the absolute value of the azimuth tracking precision is less than 0.0121° and the pitch is less than 0.0037° with the primary method. Correspondingly, they are 0.0992° and 0.0960° with the alternative method. These precisions meet the requirements of SRSIs. In addition, recalibration due to mechanical vibration during the satellite’s launch may invalidate the above methods, leading to the failure of SRSIs. Hence, we propose a dedicated injection parameter strategy to rectify the sunlight angles to capture and track the sunlight successfully. The stable and effective results in the ultraviolet to near-infrared spectrum validate the SRSI’s high-precision sunlight tracking performance. Furthermore, the above methods can also be applied to all orbital inclinations and may provide a solution for capturing and tracking moving targets.
- Open Access
Solid Particle Swarm Measurement in Jet Fuel Based on Mie Scattering Theory and Extinction Method
To overcome the disadvantages of small and random samples in static detection, this paper presents a study on dynamic measurements of solid particles in jet fuel using large samples. In this paper, the Mie scattering theory and Lambert-Beer law are used to analyze the scattering characteristics of copper particles in jet fuel. We have presented a prototype for multi-angle scattered and transmitted light intensity measurements of particle swarms in jet fuel which is used to test the scattering characteristics of the jet fuel mixture with 0.5–10 μm particle sizes and 0–1 mg/L concentrations of copper particles. The vortex flow rate was converted to an equivalent pipe flow rate using the equivalent flow method. Tests were conducted at equivalent flow rates of 187, 250 and 310 L/min. Through numerical calculations and experiments, it has been discovered that the intensity of the scattering signal decreases as the scattering angle increases. Meanwhile, both the scattered light intensity and transmitted light intensity would vary with the particle size and mass concentration. Finally, the relationship equation between light intensity and particle parameters has also been summarized in the prototype based on the experimental results, which proves its detection capability.
Open AccessSolid Particle Swarm Measurement in Jet Fuel Based on Mie Scattering Theory and Extinction Method
To overcome the disadvantages of small and random samples in static detection, this paper presents a study on dynamic measurements of solid particles in jet fuel using large samples. In this paper, the Mie scattering theory and Lambert-Beer law are used to analyze the scattering characteristics of copper particles in jet fuel. We have presented a prototype for multi-angle scattered and transmitted light intensity measurements of particle swarms in jet fuel which is used to test the scattering characteristics of the jet fuel mixture with 0.5–10 μm particle sizes and 0–1 mg/L concentrations of copper particles. The vortex flow rate was converted to an equivalent pipe flow rate using the equivalent flow method. Tests were conducted at equivalent flow rates of 187, 250 and 310 L/min. Through numerical calculations and experiments, it has been discovered that the intensity of the scattering signal decreases as the scattering angle increases. Meanwhile, both the scattered light intensity and transmitted light intensity would vary with the particle size and mass concentration. Finally, the relationship equation between light intensity and particle parameters has also been summarized in the prototype based on the experimental results, which proves its detection capability.