Yskandar Hamam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yskandar Hamam has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Josiah Lange Munda
Tshwane University of Technology
3 shared publications - Adedayo Owosuhi
Department of Electrical Engineering, French South African Institute of Technology (F’SATI), Tshwane University of Technology, Pretoria 0001, South Africa
2 shared publications - Emmanuel Rotimi Sadiku
Department of Chemical, Metallurgical and Materials Engineering, Tshwane University of Technology, Pretoria, 0001, South Africa
1 shared publication - Louwrance Ngoma
Tshwane University of Technology, South Africa
1 shared publication - Oluwaseye Samson Adedoja
Department of Chemical, Metallurgical and Materials Engineering, Tshwane University of Technology, Staatsartillerie Rd, Pretoria West, Pretoria 0183, South Africa
1 shared publication
Latest Publications
- Open Access
Power System Frequency Response Enhancement Using Optimal Placement and Sizing of Battery Energy Storage Systems
The increasing penetration of converter-interfaced renewable energy sources has led to reduced system inertia and increased frequency stability challenges in modern power systems. Battery energy storage systems (BESSs) provide fast active power support. However, their effectiveness depends on the installation location, power rating, and network characteristics. This paper proposes a power-flow-informed, sensitivity-based method for the optimal placement and sizing of distributed BESSs to improve the frequency nadir and rate of change of frequency (RoCoF). The method integrates marginal frequency sensitivity obtained from time-domain simulations with network coupling information derived from power-flow analysis within a constrained optimization framework solved using particle swarm optimization. The network coupling weight, derived from voltage sensitivity, represents the steady-state electrical connectivity and active power redistribution capability, rather than transient frequency dynamics. It is used in combination with frequency sensitivity to improve the discrimination of candidate buses. The method is evaluated on the IEEE 39-bus system under multiple generator outage contingencies. For the most severe contingency (G01), the baseline system exhibits a frequency nadir of 55.9230 Hz and an RoCoF of 0.2404 Hz/s. With the proposed method, the frequency nadir improves to 58.6561 Hz, corresponding to an increase of 2.7330 Hz (4.88%), while the RoCoF is reduced to 0.1224 Hz/s (49.17% reduction). The optimal solution distributes a total BESS capacity of 298 MW across multiple buses, with the largest allocation of 46 MW at Bus 36. Across additional contingencies, the proposed method consistently achieves higher frequency nadirs and lower RoCoFs compared with both the baseline system and benchmark placement methods. The results demonstrate that combining dynamic frequency sensitivity with power-flow-based network coupling provides a physically consistent and computationally efficient strategy for distributed BESS allocation in low-inertia power systems.
Open AccessPower System Frequency Response Enhancement Using Optimal Placement and Sizing of Battery Energy Storage Systems
The increasing penetration of converter-interfaced renewable energy sources has led to reduced system inertia and increased frequency stability challenges in modern power systems. Battery energy storage systems (BESSs) provide fast active power support. However, their effectiveness depends on the installation location, power rating, and network characteristics. This paper proposes a power-flow-informed, sensitivity-based method for the optimal placement and sizing of distributed BESSs to improve the frequency nadir and rate of change of frequency (RoCoF). The method integrates marginal frequency sensitivity obtained from time-domain simulations with network coupling information derived from power-flow analysis within a constrained optimization framework solved using particle swarm optimization. The network coupling weight, derived from voltage sensitivity, represents the steady-state electrical connectivity and active power redistribution capability, rather than transient frequency dynamics. It is used in combination with frequency sensitivity to improve the discrimination of candidate buses. The method is evaluated on the IEEE 39-bus system under multiple generator outage contingencies. For the most severe contingency (G01), the baseline system exhibits a frequency nadir of 55.9230 Hz and an RoCoF of 0.2404 Hz/s. With the proposed method, the frequency nadir improves to 58.6561 Hz, corresponding to an increase of 2.7330 Hz (4.88%), while the RoCoF is reduced to 0.1224 Hz/s (49.17% reduction). The optimal solution distributes a total BESS capacity of 298 MW across multiple buses, with the largest allocation of 46 MW at Bus 36. Across additional contingencies, the proposed method consistently achieves higher frequency nadirs and lower RoCoFs compared with both the baseline system and benchmark placement methods. The results demonstrate that combining dynamic frequency sensitivity with power-flow-based network coupling provides a physically consistent and computationally efficient strategy for distributed BESS allocation in low-inertia power systems.
- Open Access
- 16 May 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (10) , 4566
Multicriteria Decision-Making for Sustainable Mining: Evaluating the Transition to Net-Zero-Carbon Energy Systems
Transitioning to sustainability is particularly challenging in the mining domain since operations must also be economically viable and meet operational efficiency requirements. Several competing criteria, including stakeholder interests and technological uncertainties, complicate the selection of appropriate sustainable technologies. This study evaluates sustainable mining technologies by using a novel multicriteria decision-making framework. Six alternatives were assessed against ten criteria through expert consultation with eight academic professionals. The research employs three fuzzy methods (TOPSIS, COPRAS, and VIKOR) integrated through a proposed Geometric Inverse Distance Aggregation (GIDA) approach. The results demonstrate that waste heat recovery systems are the optimal solution with the highest GIDA score (0.0319) and agreement (99.99%), followed by solar-powered mining (0.0232, 82.12% agreement). The findings suggest a practical implementation pathway, prioritizing proven technologies while preparing for emerging solutions. This research contributes to the sustainable mining literature by providing a comprehensive evaluation framework and practical implementation guidance for mining companies transitioning to sustainable operations.
- 16 May 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (10) , 4566
Open AccessMulticriteria Decision-Making for Sustainable Mining: Evaluating the Transition to Net-Zero-Carbon Energy Systems
Transitioning to sustainability is particularly challenging in the mining domain since operations must also be economically viable and meet operational efficiency requirements. Several competing criteria, including stakeholder interests and technological uncertainties, complicate the selection of appropriate sustainable technologies. This study evaluates sustainable mining technologies by using a novel multicriteria decision-making framework. Six alternatives were assessed against ten criteria through expert consultation with eight academic professionals. The research employs three fuzzy methods (TOPSIS, COPRAS, and VIKOR) integrated through a proposed Geometric Inverse Distance Aggregation (GIDA) approach. The results demonstrate that waste heat recovery systems are the optimal solution with the highest GIDA score (0.0319) and agreement (99.99%), followed by solar-powered mining (0.0232, 82.12% agreement). The findings suggest a practical implementation pathway, prioritizing proven technologies while preparing for emerging solutions. This research contributes to the sustainable mining literature by providing a comprehensive evaluation framework and practical implementation guidance for mining companies transitioning to sustainable operations.
- Open Access
- 26 January 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (3) , 1077
A New Framework for Active Loss Reduction and Voltage Profile Enhancement in a Distributed Generation-Dominated Radial Distribution Network
In recent times, a significant amount of power loss and system instability due to high voltage deviation experienced by modern power systems, in addition to the pressing issues challenging the power industry such as pollution—especially the emission of greenhouse gases—and aging infrastructures, have posed a serious threat to system operations. Distributed generation has been identified as one main solution capable of reducing pollution when solar and wind power are used and, hence, rejuvenating dilapidated infrastructures and redeeming climatic changes. This paper presents a novel two-stage approach for the identification of suitable locations for DG placement and the sizing of DG for loss reduction and voltage stability enhancement. The first stage explored the use of a network structure to develop a coupling factor (CF) approach that was non-iterative in nature to determine suitable DG locations. In the second stage, the size of the DG was determined using the particle swarm optimization (PSO) algorithm. The main objective was to obtain an optimal voltage profile of the system under consideration while lowering the power loss in the system and ensuring network stability amidst DG incorporation. The model design, optimization and simulation were carried out using the MATLAB 2016a environment and the IEEE 33-bus test system, in which DG was integrated. The influence of increasing the level of DG placement in the system was then investigated. The forward/backward sweep method was applied to monitor the optimization process. The voltage profiles for both the base case when no DG was integrated and the case of incremental DG integration were considered. The results obtained for both single and multiple DG integration are compared with those obtained using the existing methods. The results show the efficiency and applicability of the new non-iterative scheme in the quick identification of DG locations for voltage profile enhancement and network real power loss reduction in radial distribution networks.
- 26 January 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (3) , 1077
Open AccessA New Framework for Active Loss Reduction and Voltage Profile Enhancement in a Distributed Generation-Dominated Radial Distribution Network
In recent times, a significant amount of power loss and system instability due to high voltage deviation experienced by modern power systems, in addition to the pressing issues challenging the power industry such as pollution—especially the emission of greenhouse gases—and aging infrastructures, have posed a serious threat to system operations. Distributed generation has been identified as one main solution capable of reducing pollution when solar and wind power are used and, hence, rejuvenating dilapidated infrastructures and redeeming climatic changes. This paper presents a novel two-stage approach for the identification of suitable locations for DG placement and the sizing of DG for loss reduction and voltage stability enhancement. The first stage explored the use of a network structure to develop a coupling factor (CF) approach that was non-iterative in nature to determine suitable DG locations. In the second stage, the size of the DG was determined using the particle swarm optimization (PSO) algorithm. The main objective was to obtain an optimal voltage profile of the system under consideration while lowering the power loss in the system and ensuring network stability amidst DG incorporation. The model design, optimization and simulation were carried out using the MATLAB 2016a environment and the IEEE 33-bus test system, in which DG was integrated. The influence of increasing the level of DG placement in the system was then investigated. The forward/backward sweep method was applied to monitor the optimization process. The voltage profiles for both the base case when no DG was integrated and the case of incremental DG integration were considered. The results obtained for both single and multiple DG integration are compared with those obtained using the existing methods. The results show the efficiency and applicability of the new non-iterative scheme in the quick identification of DG locations for voltage profile enhancement and network real power loss reduction in radial distribution networks.
- Open Access
Maximizing the Integration of a Battery Energy Storage System–Photovoltaic Distributed Generation for Power System Harmonic Reduction: An Overview
The highly variable power generated from a battery energy storage system (BESS)–photovoltaic distributed generation (PVDG) causes harmonic distortions in distribution systems (DSs) due to the intermittent nature of solar energy and high voltage rises or falls in the BESS. Harmonic distortions are major concerns in the DS, especially when the sizes and locations of these resources are sub-optimal. As a result, many studies are being performed on the optimal allocation of BESS/PVDG systems in distribution network systems. In this regard, this paper seeks to review the existing planning models, optimization methods and renewable energy resources that uncertainty models have employed in solving BESS/PVDGs allocation problems in terms of obtaining optimal solutions/allocations and curtailing the harmonic contents of the DSs. However, studies on optimal allocation planning of BESS/PVDGs have achieved minimum cost but were not able to meet the standard harmonic level of the DSs. The results identified GA, PSO and AIS as some of the most used methodologies while LP, MILP and different configurations of NLP were used in the model formulations of BESS/PVDGs problems. The results also revealed DC-link voltage and switching and grid voltage harmonics as the notable causes and sources of harmonic distortions in BESS/PVDG systems. The current allocation models presented in the recent literature for the planning of BESS/PVDGs do not include the variables necessary for curtailing the harmonic contents in their planning formulations. This paper, therefore, recommends an improved and all-encompassing planning model with an efficient intelligent search algorithm capable of obtaining a global optimum solution and curtailing harmonic distortions from the BESS/PVDG-connected DSs.
Open AccessMaximizing the Integration of a Battery Energy Storage System–Photovoltaic Distributed Generation for Power System Harmonic Reduction: An Overview
The highly variable power generated from a battery energy storage system (BESS)–photovoltaic distributed generation (PVDG) causes harmonic distortions in distribution systems (DSs) due to the intermittent nature of solar energy and high voltage rises or falls in the BESS. Harmonic distortions are major concerns in the DS, especially when the sizes and locations of these resources are sub-optimal. As a result, many studies are being performed on the optimal allocation of BESS/PVDG systems in distribution network systems. In this regard, this paper seeks to review the existing planning models, optimization methods and renewable energy resources that uncertainty models have employed in solving BESS/PVDGs allocation problems in terms of obtaining optimal solutions/allocations and curtailing the harmonic contents of the DSs. However, studies on optimal allocation planning of BESS/PVDGs have achieved minimum cost but were not able to meet the standard harmonic level of the DSs. The results identified GA, PSO and AIS as some of the most used methodologies while LP, MILP and different configurations of NLP were used in the model formulations of BESS/PVDGs problems. The results also revealed DC-link voltage and switching and grid voltage harmonics as the notable causes and sources of harmonic distortions in BESS/PVDG systems. The current allocation models presented in the recent literature for the planning of BESS/PVDGs do not include the variables necessary for curtailing the harmonic contents in their planning formulations. This paper, therefore, recommends an improved and all-encompassing planning model with an efficient intelligent search algorithm capable of obtaining a global optimum solution and curtailing harmonic distortions from the BESS/PVDG-connected DSs.