Tingting Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tingting Li has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Huifang Ji
School of Pharmacy
3 shared publications- Ruiping Zhang
The Radiology Department of Shanxi Provincial People’s Hospital, Fifth Hospital of Shanxi Medical University, Taiyuan, China
3 shared publications Yuanqing Huo
Academy of Medical Sciences
3 shared publicationsMengni Jia
School of Pharmacy
2 shared publicationsWeihua Fu
School of Pharmacy, Shanxi Medical University, Taiyuan 030001, China
2 shared publicationsXueqi Li
School of Pharmacy, Shanxi Medical University, Taiyuan 030001, China
2 shared publications
Latest Publications
- 26 March 2026
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 18 (13) , 18755-18768
Multimodal and Noninvasive Diagnosis of MNP-PEG-Gd Nanoprobe for Hepatic Fibrosis Based on Magnetic Resonance and Photoacoustic and Photoacoutic Microscopy Imaging
Hepatic fibrosis is a pivotal transitional phase in the progression of various chronic hepatic diseases toward cirrhosis and hepatocellular carcinoma. Timely detection and precise staging of hepatic fibrosis are crucial for reversing the disease trajectory. A single imaging modality often fails to dehepatically provide the comprehensive diagnostic information necessary for accurate disease assessment. Multimodal imaging, which integrates various imaging techniques, has the potential to enhance diagnostic accuracy through complementary benefits. In this study, we utilized endogenous natural melanin as a nanocarrier to develop the multimodal nanoprobe MNP-PEG-Gd. This probe facilitates the complementary integration of Magnetic Resonance Imaging (MRI), which provides excellent anatomical resolution with highly sensitive Photoacoustic Imaging (PAI) and high-spatial-resolution Photoacoustic Microscopy (PAM). The MNP–PEG–Gd nanoprobe passively targets and accumulates in thehepatic region, and in vivo results indicate that MRI/PAI/PAM diagnoses align closely with biopsy findings. Moreover, our MNP–PEG–Gd nanoprobe demonstrates excellent biosafety in both in vitro and in vivo settings. This work suggests that MNP–PEG–Gd is a promising candidate for use as a contrast agent in diagnosing stages of hepatic fibrosis through multimodal imaging.
- 26 March 2026
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 18 (13) , 18755-18768
Multimodal and Noninvasive Diagnosis of MNP-PEG-Gd Nanoprobe for Hepatic Fibrosis Based on Magnetic Resonance and Photoacoustic and Photoacoutic Microscopy Imaging
Hepatic fibrosis is a pivotal transitional phase in the progression of various chronic hepatic diseases toward cirrhosis and hepatocellular carcinoma. Timely detection and precise staging of hepatic fibrosis are crucial for reversing the disease trajectory. A single imaging modality often fails to dehepatically provide the comprehensive diagnostic information necessary for accurate disease assessment. Multimodal imaging, which integrates various imaging techniques, has the potential to enhance diagnostic accuracy through complementary benefits. In this study, we utilized endogenous natural melanin as a nanocarrier to develop the multimodal nanoprobe MNP-PEG-Gd. This probe facilitates the complementary integration of Magnetic Resonance Imaging (MRI), which provides excellent anatomical resolution with highly sensitive Photoacoustic Imaging (PAI) and high-spatial-resolution Photoacoustic Microscopy (PAM). The MNP–PEG–Gd nanoprobe passively targets and accumulates in thehepatic region, and in vivo results indicate that MRI/PAI/PAM diagnoses align closely with biopsy findings. Moreover, our MNP–PEG–Gd nanoprobe demonstrates excellent biosafety in both in vitro and in vivo settings. This work suggests that MNP–PEG–Gd is a promising candidate for use as a contrast agent in diagnosing stages of hepatic fibrosis through multimodal imaging.
- 31 January 2026
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 262, 115499
Vitamin A-modified melanin nanoparticles for photoacoustic imaging-guided photothermal therapy of hepatic fibrosis
- 31 January 2026
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 262, 115499
Vitamin A-modified melanin nanoparticles for photoacoustic imaging-guided photothermal therapy of hepatic fibrosis
- 18 December 2024
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (1) , 386-397
Quercetin-Loaded Melanin Nanoparticles Decorated with Collagenase Mediates Synergistic Immunomodulation and Restores Extracellular Matrix Homeostasis in Liver Fibrosis
Liver fibrosis is a chronic disease that lacks effective drug treatment. Chronic damage and inflammation lead to the formation of collagen and fibrous scars. However, the excessive accumulation of collagen I significantly hinders the delivery of drugs into liver tissue. Therefore, this study developed a quercetin-loaded melanin nanoparticle codecorated collagenase (MNP-QUE-COL) for the treatment of liver fibrosis. These results showed that MNP-QUE-COL degraded excessive collagen I, thereby efficiently delivering melanin and quercetin into the liver tissue. MNP-QUE-COL exhibited optimal PA/MRI dual-mode imaging ability. In addition, the synergistic anti-inflammatory and reactive oxygen species scavenging function of quercetin and melanin was achieved by regulation of M1-M2 macrophage polarization and inhibition of pro-inflammatory cytokine release, reshaping the imbalanced extracellular interstitial inflammatory environment. The results of this research suggest that MNP-QUE-COL is a safe and efficient therapeutic nanoplatform for liver fibrosis, showing promise as a potential therapeutic strategy for liver fibrosis and associated diseases.
- 18 December 2024
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (1) , 386-397
Quercetin-Loaded Melanin Nanoparticles Decorated with Collagenase Mediates Synergistic Immunomodulation and Restores Extracellular Matrix Homeostasis in Liver Fibrosis
Liver fibrosis is a chronic disease that lacks effective drug treatment. Chronic damage and inflammation lead to the formation of collagen and fibrous scars. However, the excessive accumulation of collagen I significantly hinders the delivery of drugs into liver tissue. Therefore, this study developed a quercetin-loaded melanin nanoparticle codecorated collagenase (MNP-QUE-COL) for the treatment of liver fibrosis. These results showed that MNP-QUE-COL degraded excessive collagen I, thereby efficiently delivering melanin and quercetin into the liver tissue. MNP-QUE-COL exhibited optimal PA/MRI dual-mode imaging ability. In addition, the synergistic anti-inflammatory and reactive oxygen species scavenging function of quercetin and melanin was achieved by regulation of M1-M2 macrophage polarization and inhibition of pro-inflammatory cytokine release, reshaping the imbalanced extracellular interstitial inflammatory environment. The results of this research suggest that MNP-QUE-COL is a safe and efficient therapeutic nanoplatform for liver fibrosis, showing promise as a potential therapeutic strategy for liver fibrosis and associated diseases.
- 3 March 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (10) , 12797-12808
Dual-modality and Noninvasive Diagnostic of MNP–PEG–Mn Nanoprobe for Renal Fibrosis Based on Photoacoustic and Magnetic Resonance Imaging
To date, imaging-guided multimodality therapy is important to improve the accuracy of the diagnosis of renal fibrosis, and nanoplatforms for imaging-guided multimodality diagnosis are gaining more and more attention. There are many limitations and deficiencies in clinical use for early-stage diagnosis of renal fibrosis, and multimodal imaging can contribute more thoroughly and provide in-detail information for effective clinical diagnosis. Melanin is an endogenous biomaterial, and we developed an ultrasmall particle size melanin nanoprobe (MNP-PEG-Mn) based on photoacoustic (PA) and magnetic resonance (MR) dual-modal imaging. MNP-PEG-Mn nanoprobe, with the average diameter about 2.7 nm, can be passively targeted for accumulation in the kidney, and it has excellent free radical scavenging and antioxidant abilities without further exacerbating renal fibrosis. Using the normal group signal as a control, the dual-modal imaging results showed that the MR imaging (MAI) and PA imaging (PAI) signals reached the strongest at 6 h when MNP-PEG-Mn entered the 7 day renal fibrosis group via the left vein of the tail end of the mice; however, the strength of the dual-modal imaging signal and the gradient of signal change were significantly weaker in the 28 day renal fibrosis group than in the 7 day renal fibrosis group and normal group. The phenomenon preliminarily indicates that as a PAI/MRI dual-modality contrast medium candidate, MNP-PEG-Mn has outstanding ability in clinical application potential.
- 3 March 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (10) , 12797-12808
Dual-modality and Noninvasive Diagnostic of MNP–PEG–Mn Nanoprobe for Renal Fibrosis Based on Photoacoustic and Magnetic Resonance Imaging
To date, imaging-guided multimodality therapy is important to improve the accuracy of the diagnosis of renal fibrosis, and nanoplatforms for imaging-guided multimodality diagnosis are gaining more and more attention. There are many limitations and deficiencies in clinical use for early-stage diagnosis of renal fibrosis, and multimodal imaging can contribute more thoroughly and provide in-detail information for effective clinical diagnosis. Melanin is an endogenous biomaterial, and we developed an ultrasmall particle size melanin nanoprobe (MNP-PEG-Mn) based on photoacoustic (PA) and magnetic resonance (MR) dual-modal imaging. MNP-PEG-Mn nanoprobe, with the average diameter about 2.7 nm, can be passively targeted for accumulation in the kidney, and it has excellent free radical scavenging and antioxidant abilities without further exacerbating renal fibrosis. Using the normal group signal as a control, the dual-modal imaging results showed that the MR imaging (MAI) and PA imaging (PAI) signals reached the strongest at 6 h when MNP-PEG-Mn entered the 7 day renal fibrosis group via the left vein of the tail end of the mice; however, the strength of the dual-modal imaging signal and the gradient of signal change were significantly weaker in the 28 day renal fibrosis group than in the 7 day renal fibrosis group and normal group. The phenomenon preliminarily indicates that as a PAI/MRI dual-modality contrast medium candidate, MNP-PEG-Mn has outstanding ability in clinical application potential.
- Open Access
- 8 February 2022
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2022, 1-9
Optimization and Modeling of Radial Pitch Diameter Difference in Tapping of AISI H13
The radial pitch diameter difference has a great influence on the quality of the internal thread. However, it is difficult to accurately control the radial pitch diameter difference of the thread in the tapping. Therefore, the influence of various factors on radial pitch diameter difference for tapping AISI H13 steel was studied in this paper. Parameters with optimum radial pitch diameter difference were determined by the Taguchi method, and the tapping experiment was carried out according to Taguchi L18 orthogonal array. Based on the signal-to-noise ratio and variance analysis, the experimental results were evaluated to determine the combination of factors to obtain the smallest radial pitch diameter difference and the influence level of each factor on radial pitch diameter difference, and the prediction equation of radial pitch diameter difference was established through the regression analysis. The results show that the combination of factors to obtain the smallest radial pitch diameter difference is a hone radius of 10μm, a spindle speed of 100rev/min, and a chamfer length of 2 pitches; the order of importance of the influencing factors on radial pitch diameter difference is spindle speed, followed by hone radius and chamfer length, and their percentage contribution rates are 61.54, 24.53, and 6.16, respectively; the determination coefficient R2 of the prediction equations is 0.925; the confirmation experiment conducted with 95 confidence level shows that Taguchi method and prediction equation successfully optimize and predict radial pitch diameter difference.
- 8 February 2022
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2022, 1-9
Open AccessOptimization and Modeling of Radial Pitch Diameter Difference in Tapping of AISI H13
The radial pitch diameter difference has a great influence on the quality of the internal thread. However, it is difficult to accurately control the radial pitch diameter difference of the thread in the tapping. Therefore, the influence of various factors on radial pitch diameter difference for tapping AISI H13 steel was studied in this paper. Parameters with optimum radial pitch diameter difference were determined by the Taguchi method, and the tapping experiment was carried out according to Taguchi L18 orthogonal array. Based on the signal-to-noise ratio and variance analysis, the experimental results were evaluated to determine the combination of factors to obtain the smallest radial pitch diameter difference and the influence level of each factor on radial pitch diameter difference, and the prediction equation of radial pitch diameter difference was established through the regression analysis. The results show that the combination of factors to obtain the smallest radial pitch diameter difference is a hone radius of 10μm, a spindle speed of 100rev/min, and a chamfer length of 2 pitches; the order of importance of the influencing factors on radial pitch diameter difference is spindle speed, followed by hone radius and chamfer length, and their percentage contribution rates are 61.54, 24.53, and 6.16, respectively; the determination coefficient R2 of the prediction equations is 0.925; the confirmation experiment conducted with 95 confidence level shows that Taguchi method and prediction equation successfully optimize and predict radial pitch diameter difference.