Leyla Karaca
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Leyla Karaca has a total of 90 co-authors. Here are the top co-authors by number of shared publications:
- Mecit Kantarci
Department of Radiology, Faculty of Medicine, Erzincan Binali Yıldırım University, 24100 Erzincan, Türkiye
4 shared publications - Hayri Ogul
Department of Radiology, Medical Faculty, Istanbul Medipol University, Istanbul, Turkey
3 shared publications - Akın Levent
Erzincan Binali Yildirim Univ, Fac Med, Dept Radiol, Erzincan, Turkiye
2 shared publications Aylin Okur
Department of Radiology, School of Medicine, Bozok University, Yozgat, Turkey
2 shared publicationsBerhan Pirimoglu
Department of Radiology, School of Medicine, Atatürk University, Erzurum, Turkey
2 shared publications- Ahmet Baki Yagci
Department of Radiology, Faculty of Medicine, Pamukkale University, Denizli 20070, Turkey
1 shared publication
Latest Publications
- Open Access
- 1 May 2023
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 29 (3) , 414-427
Evaluation of abdominal computed tomography findings in patients with COVID-19: a multicenter study
To evaluate the frequency of abdominal computed tomography (CT) findings in patients with coronavirus disease-2019 (COVID-19) and interrogate the relationship between abdominal CT findings and patient demographic features, clinical findings, and laboratory test results as well as the CT atherosclerosis score in the abdominal aorta. This study was designed as a multicenter retrospective study. The abdominal CT findings of 1.181 patients with positive abdominal symptoms from 26 tertiary medical centers with a positive polymerase chain-reaction test for severe acute respiratory syndrome coronavirus 2 were reviewed. The frequency of ischemic and non-ischemic CT findings as well as the association between CT findings, clinical features, and abdominal aortic calcific atherosclerosis score (AA-CAS) were recorded. Ischemic and non-ischemic abdominal CT findings were detected in 240 (20.3%) and 328 (27.7%) patients, respectively. In 147 patients (12.4%), intra-abdominal malignancy was present. The most frequent ischemic abdominal CT findings were bowel wall thickening (n = 120; 10.2%) and perivascular infiltration (n = 40; 3.4%). As for non-ischemic findings, colitis (n = 91; 7.7%) and small bowel inflammation (n = 73; 6.2%) constituted the most frequent disease processes. The duration of hospital stay was found to be higher in patients with abdominal CT findings than in patients without any positive findings (13.8 ± 13 vs. 10.4 ± 12.8 days, P < 0.001). The frequency of abdominal CT findings was significantly higher in patients who did not survive the infection than in patients who were discharged after recovery (41.7% vs. 27.4%, P < 0.001). Increased AA-CAS was found to be associated with a higher risk of ischemic conditions in abdominal CT examinations. Abdominal symptoms in patients with COVID-19 are usually associated with positive CT findings. The presence of ischemic findings on CT correlates with poor COVID-19 outcomes. A high AA-CAS is associated with abdominal ischemic findings in patients with COVID-19.
- 1 May 2023
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 29 (3) , 414-427
Open AccessEvaluation of abdominal computed tomography findings in patients with COVID-19: a multicenter study
To evaluate the frequency of abdominal computed tomography (CT) findings in patients with coronavirus disease-2019 (COVID-19) and interrogate the relationship between abdominal CT findings and patient demographic features, clinical findings, and laboratory test results as well as the CT atherosclerosis score in the abdominal aorta. This study was designed as a multicenter retrospective study. The abdominal CT findings of 1.181 patients with positive abdominal symptoms from 26 tertiary medical centers with a positive polymerase chain-reaction test for severe acute respiratory syndrome coronavirus 2 were reviewed. The frequency of ischemic and non-ischemic CT findings as well as the association between CT findings, clinical features, and abdominal aortic calcific atherosclerosis score (AA-CAS) were recorded. Ischemic and non-ischemic abdominal CT findings were detected in 240 (20.3%) and 328 (27.7%) patients, respectively. In 147 patients (12.4%), intra-abdominal malignancy was present. The most frequent ischemic abdominal CT findings were bowel wall thickening (n = 120; 10.2%) and perivascular infiltration (n = 40; 3.4%). As for non-ischemic findings, colitis (n = 91; 7.7%) and small bowel inflammation (n = 73; 6.2%) constituted the most frequent disease processes. The duration of hospital stay was found to be higher in patients with abdominal CT findings than in patients without any positive findings (13.8 ± 13 vs. 10.4 ± 12.8 days, P < 0.001). The frequency of abdominal CT findings was significantly higher in patients who did not survive the infection than in patients who were discharged after recovery (41.7% vs. 27.4%, P < 0.001). Increased AA-CAS was found to be associated with a higher risk of ischemic conditions in abdominal CT examinations. Abdominal symptoms in patients with COVID-19 are usually associated with positive CT findings. The presence of ischemic findings on CT correlates with poor COVID-19 outcomes. A high AA-CAS is associated with abdominal ischemic findings in patients with COVID-19.
- 1 November 2015
- Published by Elsevier in The Spine Journal
- Vol. 15 (11) , e5-e6
Intraosseous lipoma of sacrum
- 1 November 2015
- Published by Elsevier in The Spine Journal
- Vol. 15 (11) , e5-e6
Intraosseous lipoma of sacrum
- Open Access
- 1 January 2015
- Published by Termedia Sp. z.o.o. in Advances in Interventional Cardiology
- Vol. 3 (3) , 218-223
The utility of cardiac magnetic resonance imaging in Kounis syndrome
Introduction : Current diagnostic measurements used to assess myocardial involvement in Kounis syndrome, such as electrocardiography (ECG), cardiac enzymes, and troponin levels, are relatively insensitive to small but potentially significant functional change. According to our review of the...
- 1 January 2015
- Published by Termedia Sp. z.o.o. in Advances in Interventional Cardiology
- Vol. 3 (3) , 218-223
Open AccessThe utility of cardiac magnetic resonance imaging in Kounis syndrome
Introduction : Current diagnostic measurements used to assess myocardial involvement in Kounis syndrome, such as electrocardiography (ECG), cardiac enzymes, and troponin levels, are relatively insensitive to small but potentially significant functional change. According to our review of the...
- 25 June 2014
- Published by Springer Nature in European Radiology
- Vol. 24 (10) , 2606-2613
Extra-articular contrast material leaks into locations unrelated to the injection path in shoulder MR arthrography
To evaluate the localisation, frequency and amount of extravasation in patients with extra-articular contrast material leak into locations unrelated to the injection path in shoulder magnetic resonance (MR) arthrography and associated shoulder disorders. The sites of extravasation were determined on the shoulder MR arthrography of 40 patients. The extravasations were measured on three vertical planes of the MR arthrography. Sufficient joint distension was assessed according to the transverse diameters of the axillary recess on coronal MR images. Extravasation of the contrast material occurred through the subscapular recess, the synovium of the biceps, and the axillary recess. In four cases, extravasations were observed in more than one anatomic location. The most common site of extravasation was along the subscapularis muscle. Superior labrum anterior-posterior (SLAP) lesions were found to be most frequently associated with extravasations. The amount of extravasation was significantly higher in patients with adhesive capsulitis compared with the patients with a different diagnosis (p = 0.022). The extravasations adjacent to the axillary recess do not always indicate glenohumeral ligament pathology. Massive subscapular extravasations were most frequently associated with adhesive capsulitis and SLAP lesions, and might be considered in the MR arthrography report. • Contrast material extravasation may reduce the diagnostic value of shoulder MR arthrography. • The extravasations may occur into locations unrelated to the injection path. • The extravasations adjacent to axillary recess can be misleading for HAGL lesion. • Massive subscapular extravasations were frequently associated with adhesive capsulitis and SLAP lesions.
- 25 June 2014
- Published by Springer Nature in European Radiology
- Vol. 24 (10) , 2606-2613
Extra-articular contrast material leaks into locations unrelated to the injection path in shoulder MR arthrography
To evaluate the localisation, frequency and amount of extravasation in patients with extra-articular contrast material leak into locations unrelated to the injection path in shoulder magnetic resonance (MR) arthrography and associated shoulder disorders. The sites of extravasation were determined on the shoulder MR arthrography of 40 patients. The extravasations were measured on three vertical planes of the MR arthrography. Sufficient joint distension was assessed according to the transverse diameters of the axillary recess on coronal MR images. Extravasation of the contrast material occurred through the subscapular recess, the synovium of the biceps, and the axillary recess. In four cases, extravasations were observed in more than one anatomic location. The most common site of extravasation was along the subscapularis muscle. Superior labrum anterior-posterior (SLAP) lesions were found to be most frequently associated with extravasations. The amount of extravasation was significantly higher in patients with adhesive capsulitis compared with the patients with a different diagnosis (p = 0.022). The extravasations adjacent to the axillary recess do not always indicate glenohumeral ligament pathology. Massive subscapular extravasations were most frequently associated with adhesive capsulitis and SLAP lesions, and might be considered in the MR arthrography report. • Contrast material extravasation may reduce the diagnostic value of shoulder MR arthrography. • The extravasations may occur into locations unrelated to the injection path. • The extravasations adjacent to axillary recess can be misleading for HAGL lesion. • Massive subscapular extravasations were frequently associated with adhesive capsulitis and SLAP lesions.