Jun Iba
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jun Iba has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Ken Ishii
Faculty of Engineering Hokkaido University Sapporo Hokkaido Japan
3 shared publicationsKoichi Watanabe
Institute of Technology Shimizu Corporation Tokyo Japan
3 shared publicationsKou Miyamoto
Shimizu Corporation
2 shared publications- Kou Miyamoto
Institute of Technology, Shimizu Corporation, Koto, Tokyo 135-0044, Japan
2 shared publications Masaru Kikuchi
Faculty of Engineering Hokkaido University Sapporo Hokkaido Japan
2 shared publications- Ken Ishii
Faculty of Engineering, Hokkaido University, Sapporo, Hokkaido, Japan
1 shared publication
Latest Publications
- 1 September 2025
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 54 (15) , 3811-3827
On the Response of Seismically Isolated Buildings Equipped with Quasi‐Zero Stiffness Device and Tuned Inerter Dampers
This study demonstrates that s eismically isolated buildings incorporating a q uasi‐zero stiffness device and t uned inerter damper (SQT) system mitigate displacement and acceleration responses, confirming the feasibility and robustness of this passive seismic control strategy. We propose design equations for the tuned inerter damper in an SQT system. To gain fundamental insights, we model the SQT system as a two‐degree‐of‐freedom system and examine it from both theoretical and experimental perspectives. A theoretical solution for sinusoidal excitation is derived to provide a general understanding. A shaking table test validates the theoretical solution and confirms the SQT system's effectiveness in damping the earthquake response. Close agreement between the numerical and experimental results indicates that the theoretical model accurately predicts amplitude‐frequency curves. The test results show that the SQT system limits the displacement response to be within the criterion and reduces the acceleration response to levels comparable to conventional seismic isolation under sinusoidal and earthquake excitations.
- 1 September 2025
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 54 (15) , 3811-3827
On the Response of Seismically Isolated Buildings Equipped with Quasi‐Zero Stiffness Device and Tuned Inerter Dampers
This study demonstrates that s eismically isolated buildings incorporating a q uasi‐zero stiffness device and t uned inerter damper (SQT) system mitigate displacement and acceleration responses, confirming the feasibility and robustness of this passive seismic control strategy. We propose design equations for the tuned inerter damper in an SQT system. To gain fundamental insights, we model the SQT system as a two‐degree‐of‐freedom system and examine it from both theoretical and experimental perspectives. A theoretical solution for sinusoidal excitation is derived to provide a general understanding. A shaking table test validates the theoretical solution and confirms the SQT system's effectiveness in damping the earthquake response. Close agreement between the numerical and experimental results indicates that the theoretical model accurately predicts amplitude‐frequency curves. The test results show that the SQT system limits the displacement response to be within the criterion and reduces the acceleration response to levels comparable to conventional seismic isolation under sinusoidal and earthquake excitations.
- 29 September 2024
- Published by Springer Nature
- p. 3-14
Dynamic Characteristics of Seismic Isolation with Quasi-Zero Stiffness, Rotational Inertia
- 29 September 2024
- Published by Springer Nature
- p. 3-14
Dynamic Characteristics of Seismic Isolation with Quasi-Zero Stiffness, Rotational Inertia
- Open Access
- 23 March 2023
- Published by Wiley in Structural Control and Health Monitoring
- Vol. 2023, 1-24
Development of Nonlinear Geometric Seismic Isolation with a Duffing Spring
Seismic isolation is widely used in several countries, and the number of seismically isolated buildings has increased rapidly in recent decades. Seismic isolation extends the natural period of a building to decrease the absolute acceleration and seismic force. As there is a trade-off between the absolute acceleration and displacement, a soft layer results in a large displacement for a large seismic wave, but the hard one causes the large absolute acceleration even for a small seismic wave. The restoring force of a Duffing spring is given by the third and first orders of the displacement. This spring has been applied to protect a building from large earthquake waves. However, the influence of the coefficient of the Duffing spring that determines the dynamic characteristics of the system has not been clarified. Thus, a used Duffing spring may not be appropriate for seismic resistance. Moreover, most studies are based on analytical methods, and the advantages of the Duffing isolation have not been verified in an actual system. To address these problems, this paper reveals the influence of the coefficient of the Duffing spring on structural responses to seismic waves. Moreover, this paper devised a way to implement a Duffing spring for seismic isolation and carried out experiments to verify the validity in actual systems. The experimental results presented that the Duffing spring was effective in protecting a building in actual systems.
- 23 March 2023
- Published by Wiley in Structural Control and Health Monitoring
- Vol. 2023, 1-24
Open AccessDevelopment of Nonlinear Geometric Seismic Isolation with a Duffing Spring
Seismic isolation is widely used in several countries, and the number of seismically isolated buildings has increased rapidly in recent decades. Seismic isolation extends the natural period of a building to decrease the absolute acceleration and seismic force. As there is a trade-off between the absolute acceleration and displacement, a soft layer results in a large displacement for a large seismic wave, but the hard one causes the large absolute acceleration even for a small seismic wave. The restoring force of a Duffing spring is given by the third and first orders of the displacement. This spring has been applied to protect a building from large earthquake waves. However, the influence of the coefficient of the Duffing spring that determines the dynamic characteristics of the system has not been clarified. Thus, a used Duffing spring may not be appropriate for seismic resistance. Moreover, most studies are based on analytical methods, and the advantages of the Duffing isolation have not been verified in an actual system. To address these problems, this paper reveals the influence of the coefficient of the Duffing spring on structural responses to seismic waves. Moreover, this paper devised a way to implement a Duffing spring for seismic isolation and carried out experiments to verify the validity in actual systems. The experimental results presented that the Duffing spring was effective in protecting a building in actual systems.